Cited by 115Body Composition Measurement TechniquesElectrical and Bioimpedance TomographySports Performance and Training

Bioelectrical impedance analysis versus reference methods in the assessment of body composition in athletes

Open access
Campa, Francesco, Gobbo, Luis Alberto, Stagi, Silvia, Cyrino, Leticia Trindade, Toselli, Stefania, Marini, Elisabetta, Coratella, Giuseppe·2022·European Journal of Applied Physiology

Abstract

The present systematic review aimed to compare the accuracy of Bioelectrical Impedance Analysis (BIA) and Bioelectrical Impedance Vector Analysis (BIVA) vs. reference methods for the assessment of body composition in athletes. Studies were identified based on a systematic search of internationally electronic databases (PubMed and Scopus) and hand searching of the reference lists of the included studies. In total, 42 studies published between 1988 and 2021 were included. The methodological quality was assessed using the Quality Assessment Tool for Observational Cohort and Cross-sectional Studies as recommended by the National Institute of Health. Twenty-three studies had an overall good rating in terms of quality, while 13 were rated as fair and 6 as poor, resulting in a low to moderate risk of bias. Fat mass was inconsistently determined using BIA vs. the reference methods, regardless of the BIA-technology. When using the foot to hand technology with predictive equations for athletes, a good agreement between BIA and the reference methods was observed for fat-free mass, total body, intra and extra cellular water. However, an underestimation in fat-free mass and body fluids was found when using generalized predictive equations. Classic and Specific BIVA represented a valid approach for assessing body fluids (Classic BIVA) and percentage of fat mass (Specific BIVA). The present systematic review suggests that BIA and BIVA can be used for assessing body composition in athletes, provided that foot-to-hand technology, predictive equations, and BIVA references for athletes are used.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00421-021-04879-y

Cites

81 of 81 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Many of these studies merely mention the type of software employed, making it impossible to discern which formulas were used to convert raw bioelectrical parameters into components of body mass.

    “Many of these studies merely mention the type of software employed, making it impossible to discern which formulas were used to convert raw bioelectrical parameters into components of body mass.”

    From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [24]

    The discussion (section 365; page unavailable) says studies using hand-to-hand, leg-to-leg, and direct segmental BIA did not report the predictive equations used to determine percentage fat mass. The review therefore supports the difficulty of identifying the formulas, but the passages do not establish the more specific claim that those studies merely named the software employed. (LLM, conf=0.83)

    Experimental — accuracy not yet measured
  • Various studies including those providing reference data based on BIA do not disclose the procedures used.

    “A further question is that various studies including those providing reference data based on BIA do not disclose the procedures used [24, 28].”

    From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [24]

    In “BIA vs. reference methods: FM and FFM” (lines 262–271), the review says only seven of 16 studies using foot-to-hand BIA to assess fat mass reported their predictive equations. It therefore supports a narrower concern about undisclosed analytical methods, but does not establish that studies providing BIA-based reference data failed to disclose their procedures generally. (LLM, conf=0.82)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Campa, F., Gobbo, L. A., Stagi, S., Cyrino, L. T., Toselli, S., Marini, E., & Coratella, G.
Affiliations
  • University of Bologna (IT)
  • University of Cagliari (IT)
  • University of Milan (IT)
Corresponding author
Coratella, Giuseppe
Venue
European Journal of Applied Physiology
Published
2022-01-24
Volume
122
Issue
3
Pages
561-589
ISSN
  • 0020-9376 (ISSN-L)
  • 1439-6319
  • 1439-6327
OpenAlex
W4207084747
Cited by
115
References
81
Citations by year
2026: 22 · 2025: 28 · 2024: 27 · 2023: 18 · 2022: 20
FWCI
3.20
Type
journal article
Language
en
Open access
Locations
  • European Journal of Applied Physiology (publishedVersion)
  • PubMed (publishedVersion)
  • Archivio istituzionale della ricerca (Alma Mater Studiorum Università di Bologna) (submittedVersion, other-oa)
  • UNICA IRIS Institutional Research Information System (University of Cagliari) (submittedVersion, other-oa)
  • Padua Research Archive (University of Padova) (submittedVersion)
Topics
  • Health Sciences › Medicine › Physiology › Body Composition Measurement Techniques
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrical and Bioimpedance Tomography
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
Keywords
bioelectrical impedance analysis, bioelectrical impedance vector analysis, body composition, athletes, fat mass, fat-free mass, total body water, prediction equations, measurement accuracy, reference method
MeSH terms
Body Composition, Humans, Predictive Value of Tests, Reference Values, Electric Impedance, Athletes

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review