The DOI matches its Crossref record.
The N1 Response and Its Applications
Abstract
Some properties and applications of the N1-P2 complex (100-200 ms latency) are reviewed. N1-P2 is currently the auditory-evoked potential (AEP) of choice for estimating the pure-tone audiogram in certain subjects for whom a frequency-specific, non-behavioural measure is required. It is accurate in passively cooperative and alert older children and adults. Although generally underutilized, it is an excellent tool for assessment of functional hearing loss, and in medicolegal and industrial injury compensation claimants. Successful use of N1-P2 requires substantial tester training and skill, as well as carefully designed and efficient measurement protocols. N1-P2 reflects conscious detection of any discrete change in any subjective dimension of the auditory environment. In principle, it could be used to measure almost any threshold of discriminable change, such as in pitch, loudness, quality and source location. It is established as a physiologic correlate of phenomena such as the masking level difference. Thus, N1-P2 may have many applications as an 'objective' proxy for psychoacoustic measures that may be impractical in clinical subjects. Advances in dipole source localization and in auditory-evoked magnetic fields (AEMFs) have clarified the multiple, cortical origins of N1 and P2. These potentials are promising tools for the neurophysiologic characterization of many disorders of central auditory processing and of speech and language development. They also may be useful in direct 'functional imaging' of specific brain regions. A wide variety of potential research and clinical applications of N1 and P2, and considerable value as part of an integrated, goal-directed AEP/AEMF measurement scheme, have yet to be fully realized.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mismatch negativity (MMN), the deviance-elicited auditory deflection, explained
May, P. J. C., & Tiitinen, H. (2010) · Psychophysiology · doi:10.1111/j.1469-8986.2009.00856.x · Cited by 549
Linking Brainwaves to the Brain: An ERP Primer
Key, A. P. F., Dove, G. O., & Maguire, M. J. (2005) · Developmental Neuropsychology · doi:10.1207/s15326942dn2702_1 · Cited by 398
Speech Evoked Potentials: From the Laboratory to the Clinic
Martin, B. A., Tremblay, K. L., & Korczak, P. (2008) · Ear & Hearing · doi:10.1097/aud.0b013e3181662c0e · Cited by 357
The non-transcranial TMS-evoked potential is an inherent source of ambiguity in TMS-EEG studies
Conde, V., Tomasevic, L., Akopian, I., Stanek, K., Saturnino, G. B., Thielscher, A., Bergmann, T. O., & Siebner, H. R. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2018.10.052 · Cited by 343
High-Precision Neuromagnetic Study of the Functional Organization of the Human Auditory Cortex
Lütkenhöner, B., & Steinsträter, O. (1998) · Audiology and Neurotology · doi:10.1159/000013790 · Cited by 288
Stimulus experience modifies auditory neuromagnetic responses in young and older listeners
Ross, B., & Tremblay, K. (2009) · Hearing Research · doi:10.1016/j.heares.2008.11.012 · Cited by 159
The effects of anesthetics on brain activity and cognitive function
Heinke, W., & Koelsch, S. (2005) · Current Opinion in Anaesthesiology · doi:10.1097/01.aco.0000189879.67092.12 · Cited by 116
Yau, S. H., Brock, J., & McArthur, G. (2016) · Developmental Science · doi:10.1111/desc.12328 · Cited by 22
Electrophysiology of facilitation priming in obsessive-compulsive and panic disorders
Thomas, S. J., Gonsalvez, C. J., & Johnstone, S. J. (2016) · Clinical Neurophysiology · doi:10.1016/j.clinph.2015.05.026 · Cited by 5
Metadata
- Authors
- Hyde, M.
- Venue
- Audiology and Neurotology
- Publisher
- S. Karger AG
- Published
- 1997
- Volume
- 2
- Issue
- 5
- Pages
- 281-307
- ISSN
- 1420-3030 (ISSN-L)
- 1421-9700
- OpenAlex
- W1999448079
- Cited by
- 229
- References
- 0
- FWCI
- 0.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.