Digital Ocular Fundus Imaging: A Review
Open accessThe DOI matches its Crossref record; 129 of the 129 references it cites were found in a registry or an index.
Abstract
Ocular fundus imaging plays a key role in monitoring the health status of the human eye. Currently, a large number of imaging modalities allow the assessment and/or quantification of ocular changes from a healthy status. This review focuses on the main digital fundus imaging modality, color fundus photography, with a brief overview of complementary techniques, such as fluorescein angiography. While focusing on two-dimensional color fundus photography, the authors address the evolution from nondigital to digital imaging and its impact on diagnosis. They also compare several studies performed along the transitional path of this technology. Retinal image processing and analysis, automated disease detection and identification of the stage of diabetic retinopathy (DR) are addressed as well. The authors emphasize the problems of image segmentation, focusing on the major landmark structures of the ocular fundus: the vascular network, optic disk and the fovea. Several proposed approaches for the automatic detection of signs of disease onset and progression, such as microaneurysms, are surveyed. A thorough comparison is conducted among different studies with regard to the number of eyes/subjects, imaging modality, fundus camera used, field of view and image resolution to identify the large variation in characteristics from one study to another. Similarly, the main features of the proposed classifications and algorithms for the automatic detection of DR are compared, thereby addressing computer-aided diagnosis and computer-aided detection for use in screening programs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Medical image analysis: progress over two decades and the challenges ahead
Duncan, J. S., & Ayache, N. (2000) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.824822 · Cited by 4,140
The contourlet transform: an efficient directional multiresolution image representation
Do, M. N., & Vetterli, M. (2005) · IEEE Transactions on Image Processing · doi:10.1109/tip.2005.859376 · Cited by 3,952
Image change detection algorithms: a systematic survey
Radke, R. J., Andra, S., Al-Kofahi, O., & Roysam, B. (2005) · IEEE Transactions on Image Processing · doi:10.1109/tip.2004.838698 · Cited by 1,869
Optical coherence tomography - principles and applications
Fercher, A. F., Drexler, W., Hitzenberger, C. K., & Lasser, T. (2003) · Reports on Progress in Physics · doi:10.1088/0034-4885/66/2/204 · Cited by 1,866
Performance of fourier domain vs time domain optical coherence tomography
Leitgeb, R., Hitzenberger, C., & Fercher, A. (2003) · Optics Express · doi:10.1364/oe.11.000889 · Cited by 1,854
Retinal vessel segmentation using the 2-D Gabor wavelet and supervised classification
Soares, J. V. B., Leandro, J. J. G., Cesar, R. M., Jelinek, H. F., & Cree, M. J. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.879967 · Cited by 1,497
Retinal Imaging and Image Analysis
Abramoff, M. D., Garvin, M. K., & Sonka, M. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2084567 · Cited by 1,439
Optical coherence tomography (OCT): a review
Schmitt, J. M. (1999) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/2944.796348 · Cited by 1,188
Ultrahigh-resolution ophthalmic optical coherence tomography
Drexler, W., Morgner, U., Ghanta, R. K., Kärtner, F. X., Schuman, J. S., & Fujimoto, J. G. (2001) · Nature Medicine · doi:10.1038/86589 · Cited by 962
In vivo ultrahigh-resolution optical coherence tomography
Drexler, W., Morgner, U., Käertner, F. X., Pitris, C., Boppart, S. A., Li, X. D., Ippen, E. P., & Fujimoto, J. G. (1999) · Optics Letters · doi:10.1364/ol.24.001221 · Cited by 945
Cited by
Deep Learning and Glaucoma Specialists
Phene, S., Dunn, R. C., Hammel, N., Liu, Y., Krause, J., Kitade, N., Schaekermann, M., Sayres, R., Wu, D. J., Bora, A., et al. (2019) · Ophthalmology · doi:10.1016/j.ophtha.2019.07.024 · Cited by 186
A mobile phone-based retinal camera for portable wide field imaging
Maamari, R. N., Keenan, J. D., Fletcher, D. A., & Margolis, T. P. (2014) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2013-303797 · Cited by 166
The Empirical Evidence for the Telemedicine Intervention in Diabetes Management
Bashshur, R. L., Shannon, G. W., Smith, B. R., & Woodward, M. A. (2015) · Telemedicine and e-Health · doi:10.1089/tmj.2015.0029 · Cited by 102
Metadata
- Authors
- Bernardes, R., Serranho, P., & Lobo, C.
- Venue
- Ophthalmologica
- Publisher
- S. Karger AG
- Published
- 2011
- Volume
- 226
- Issue
- 4
- Pages
- 161-181
- ISSN
- 0030-3755 (ISSN-L)
- 1423-0267
- OpenAlex
- W2116273337
- Cited by
- 207
- References
- 129
- FWCI
- 8.96
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Digital Ocular Fundus Imaging: A Review. https://app.cochat.ai/papers/10.1159/000329597
- The paper
- Bernardes, R., Serranho, P., & Lobo, C. (2011). Digital Ocular Fundus Imaging: A Review. Ophthalmologica. https://doi.org/10.1159/000329597
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.