Digital Ocular Fundus Imaging: A Review
Open accessThe DOI matches its Crossref record; 129 of the 129 references it cites were found in a registry or an index.
Abstract
Ocular fundus imaging plays a key role in monitoring the health status of the human eye. Currently, a large number of imaging modalities allow the assessment and/or quantification of ocular changes from a healthy status. This review focuses on the main digital fundus imaging modality, color fundus photography, with a brief overview of complementary techniques, such as fluorescein angiography. While focusing on two-dimensional color fundus photography, the authors address the evolution from nondigital to digital imaging and its impact on diagnosis. They also compare several studies performed along the transitional path of this technology. Retinal image processing and analysis, automated disease detection and identification of the stage of diabetic retinopathy (DR) are addressed as well. The authors emphasize the problems of image segmentation, focusing on the major landmark structures of the ocular fundus: the vascular network, optic disk and the fovea. Several proposed approaches for the automatic detection of signs of disease onset and progression, such as microaneurysms, are surveyed. A thorough comparison is conducted among different studies with regard to the number of eyes/subjects, imaging modality, fundus camera used, field of view and image resolution to identify the large variation in characteristics from one study to another. Similarly, the main features of the proposed classifications and algorithms for the automatic detection of DR are compared, thereby addressing computer-aided diagnosis and computer-aided detection for use in screening programs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Medical image analysis: progress over two decades and the challenges ahead
Duncan, J. S., & Ayache, N. (2000) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.824822 · Cited by 4,140
The contourlet transform: an efficient directional multiresolution image representation
Do, M. N., & Vetterli, M. (2005) · IEEE Transactions on Image Processing · doi:10.1109/tip.2005.859376 · Cited by 3,952
Image change detection algorithms: a systematic survey
Radke, R. J., Andra, S., Al-Kofahi, O., & Roysam, B. (2005) · IEEE Transactions on Image Processing · doi:10.1109/tip.2004.838698 · Cited by 1,869
Optical coherence tomography - principles and applications
Fercher, A. F., Drexler, W., Hitzenberger, C. K., & Lasser, T. (2003) · Reports on Progress in Physics · doi:10.1088/0034-4885/66/2/204 · Cited by 1,866
Performance of fourier domain vs time domain optical coherence tomography
Leitgeb, R., Hitzenberger, C., & Fercher, A. (2003) · Optics Express · doi:10.1364/oe.11.000889 · Cited by 1,854
Retinal vessel segmentation using the 2-D Gabor wavelet and supervised classification
Soares, J. V. B., Leandro, J. J. G., Cesar, R. M., Jelinek, H. F., & Cree, M. J. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.879967 · Cited by 1,497
Retinal Imaging and Image Analysis
Abramoff, M. D., Garvin, M. K., & Sonka, M. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2084567 · Cited by 1,439
Optical coherence tomography (OCT): a review
Schmitt, J. M. (1999) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/2944.796348 · Cited by 1,188
Ultrahigh-resolution ophthalmic optical coherence tomography
Drexler, W., Morgner, U., Ghanta, R. K., Kärtner, F. X., Schuman, J. S., & Fujimoto, J. G. (2001) · Nature Medicine · doi:10.1038/86589 · Cited by 962
In vivo ultrahigh-resolution optical coherence tomography
Drexler, W., Morgner, U., Käertner, F. X., Pitris, C., Boppart, S. A., Li, X. D., Ippen, E. P., & Fujimoto, J. G. (1999) · Optics Letters · doi:10.1364/ol.24.001221 · Cited by 945
Marín, D., Aquino, A., Gegundez-Arias, M. E., & Bravo, J. M. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2064333 · Cited by 929
Mendonca, A. M., & Campilho, A. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.879955 · Cited by 921
Walter, T., Klein, J., Massin, P., & Erginay, A. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.806290 · Cited by 825
A Method of Photographing Fluorescence in Circulating Blood in the Human Retina
NOVOTNY, H. R., & ALVIS, D. L. (1961) · Circulation · doi:10.1161/01.cir.24.1.82 · Cited by 698
Retinal image analysis: Concepts, applications and potential
Patton, N., Aslam, T. M., MacGillivray, T., Deary, I. J., Dhillon, B., Eikelboom, R. H., Yogesan, K., & Constable, I. J. (2006) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2005.07.001 · Cited by 641
Automated Feature Extraction in Color Retinal Images by a Model Based Approach
Li, H., & Chutatape, O. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.820400 · Cited by 545
FUNDUS AUTOFLUORESCENCE IMAGING: Review and Perspectives
SCHMITZ-VALCKENBERG, S., HOLZ, F. G., BIRD, A. C., & SPAIDE, R. F. (2008) · Retina · doi:10.1097/iae.0b013e318164a907 · Cited by 537
Niemeijer, M., van Ginneken, B., Cree, M. J., Mizutani, A., Quellec, G., Sanchez, C. I., Zhang, B., Hornero, R., Lamard, M., Muramatsu, C., et al. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2033909 · Cited by 516
Automatic detection of red lesions in digital color fundus photographs
Niemeijer, M., van Ginneken, B., Staal, J., Suttorp-Schulten, M. S. A., & Abramoff, M. D. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.843738 · Cited by 504
Detection of Optic Disc in Retinal Images by Means of a Geometrical Model of Vessel Structure
Foracchia, M., Grisan, E., & Ruggeri, A. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.829331 · Cited by 445
Youssif, A. A.-H. A.-R., Ghalwash, A. Z., & Ghoneim, A. A. S. A.-R. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.900326 · Cited by 441
Can, A., Shen, H., Turner, Tanenbaum, & Roysam (1999) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/4233.767088 · Cited by 434
A fuzzy vessel tracking algorithm for retinal images based on fuzzy clustering
Tolias, Y. A., & Panas, S. M. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.700738 · Cited by 365
Retinal Vascular Imaging: A New Tool in Microvascular Disease Research
Liew, G., Wang, J. J., Mitchell, P., & Wong, T. Y. (2008) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.108.784876 · Cited by 318
Fractal Analysis of the Vascular Tree in the Human Retina
Masters, B. R. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140100 · Cited by 316
Infrared imaging of sub-retinal structures in the human ocular fundus
Elsner, A. E., Burns, S. A., Weiter, J. J., & Delori, F. C. (1996) · Vision Research · doi:10.1016/0042-6989(95)00100-e · Cited by 310
Spencer, T., Olson, J. A., McHardy, K. C., Sharp, P. F., & Forrester, J. V. (1996) · Computers and Biomedical Research · doi:10.1006/cbmr.1996.0021 · Cited by 305
Usher, D., Dumskyj, M., Himaga, M., Williamson, T. H., Nussey, S., & Boyce, J. (2004) · Diabetic Medicine · doi:10.1046/j.1464-5491.2003.01085.x · Cited by 299
Doi, K. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/13/r02 · Cited by 290
Automated Early Detection of Diabetic Retinopathy
Abràmoff, M. D., Reinhardt, J. M., Russell, S. R., Folk, J. C., Mahajan, V. B., Niemeijer, M., & Quellec, G. (2010) · Ophthalmology · doi:10.1016/j.ophtha.2010.03.046 · Cited by 287
Abràmoff, M. D., Niemeijer, M., Suttorp-Schulten, M. S. A., Viergever, M. A., Russell, S. R., & van Ginneken, B. (2008) · Diabetes Care · doi:10.2337/dc07-1312 · Cited by 277
High resolution in vivo intra-arterial imaging with optical coherence tomography
Fujimoto, J. G., Boppart, S. A., Tearney, G. J., Bouma, B. E., Pitris, C., & Brezinski, M. E. (1999) · Heart · doi:10.1136/hrt.82.2.128 · Cited by 276
Can, A., Stewart, C. V., Roysam, B., & Tanenbaum, H. L. (2002) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.990136 · Cited by 272
Automated Identification of Diabetic Retinopathy Stages Using Digital Fundus Images
Nayak, J., Bhat, P. S., Acharya U, R., Lim, C. M., & Kagathi, M. (2008) · Journal of Medical Systems · doi:10.1007/s10916-007-9113-9 · Cited by 272
Photoacoustic ophthalmoscopy for in vivo retinal imaging
Jiao, S., Jiang, M., Hu, J., Fawzi, A., Zhou, Q., Shung, K. K., Puliafito, C. A., & Zhang, H. F. (2010) · Optics Express · doi:10.1364/oe.18.003967 · Cited by 258
Effectiveness of screening and monitoring tests for diabetic retinopathy – a systematic review
Hutchinson, A., McIntosh, A., Peters, J., O'keeffe, C., Khunti, K., Baker, R., & Booth, A. (2000) · Diabetic Medicine · doi:10.1046/j.1464-5491.2000.00250.x · Cited by 248
Bursell, S.-E., Cavallerano, J. D., Cavallerano, A. A., Clermont, A. C., Birkmire-Peters, D., Aiello, L. P., & Aiello, L. M. (2001) · Ophthalmology · doi:10.1016/s0161-6420(00)00604-7 · Cited by 246
Improvement in retinal image quality with dynamic correction of the eye’s aberrations
Hofer, H., Chen, L., Yoon, G. Y., Singer, B., Yamauchi, Y., & Williams, D. R. (2001) · Optics Express · doi:10.1364/oe.8.000631 · Cited by 246
Identification of different stages of diabetic retinopathy using retinal optical images
Yun, W. L., Rajendra Acharya, U., Venkatesh, Y. V., Chee, C., Min, L. C., & Ng, E. Y. K. (2008) · Information Sciences · doi:10.1016/j.ins.2007.07.020 · Cited by 238
Pinz, A., Bernogger, S., Datlinger, P., & Kruger, A. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.730405 · Cited by 233
Ege, B. M., Hejlesen, O. K., Larsen, O. V., Møller, K., Jennings, B., Kerr, D., & Cavan, D. A. (2000) · Computer Methods and Programs in Biomedicine · doi:10.1016/s0169-2607(00)00065-1 · Cited by 214
Multifractal analysis of human retinal vessels
Stosic, T., & Stosic, B. D. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.879316 · Cited by 210
Ophthalmic fundus imaging: today and beyond
Yannuzzi, L. A., Ober, M. D., Slakter, J. S., Spaide, R. F., Fisher, Y. L., Flower, R. W., & Rosen, R. (2004) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2003.12.035 · Cited by 207
Fundus Autofluorescence and Progression of Age-related Macular Degeneration
Schmitz-Valckenberg, S., Fleckenstein, M., Scholl, H. P. N., & Holz, F. G. (2009) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2008.10.004 · Cited by 204
Lam, B. S. Y., & Yan, H. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.909827 · Cited by 193
Application of Higher Order Spectra for the Identification of Diabetes Retinopathy Stages
Acharya U, R., Chua, C. K., Ng, E. Y. K., Yu, W., & Chee, C. (2008) · Journal of Medical Systems · doi:10.1007/s10916-008-9154-8 · Cited by 179
Teng, T., Lefley, M., & Claremont, D. (2002) · Medical & Biological Engineering & Computing · doi:10.1007/bf02347689 · Cited by 179
Hipwell, J. H., Strachan, F., Olson, J. A., McHardy, K. C., Sharp, P. F., & Forrester, J. V. (2000) · Diabetic Medicine · doi:10.1046/j.1464-5491.2000.00338.x · Cited by 177
Narasimha-Iyer, H., Can, A., Roysam, B., Stewart, V., Tanenbaum, H. L., Majerovics, A., & Singh, H. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.863971 · Cited by 170
A telemedical approach to the screening of diabetic retinopathy: digital fundus photography.
Liesenfeld, B., Kohner, E., Piehlmeier, W., Kluthe, S., Aldington, S., Porta, M., Bek, T., Obermaier, M., Mayer, H., Mann, G., et al. (2000) · Diabetes Care · doi:10.2337/diacare.23.3.345 · Cited by 164
Automatic detection of retinal anatomy to assist diabetic retinopathy screening
Fleming, A., Goatman, K. A., Philip, S., Olson, J. A., & Sharp, P. F. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/2/002 · Cited by 151
Automated Detection of Fundus Photographic Red Lesions in Diabetic Retinopathy
Larsen, M., Godt, J., Larsen, N., Lund-Andersen, H., Sjølie, A. K., Agardh, E., Kalm, H., Grunkin, M., & Owens, D. R. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0418 · Cited by 150
Sasa, M., Takaori, S., Matsuoka, I., Miyazaki, T., & Miyazaki, K. (1981) · Cited by 142
Optical Imaging Modalities for Biomedical Applications
Dhawan, A. P., D'Alessandro, B., & Fu, X. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2081975 · Cited by 133
Accuracy and Reliability of Remote Retinopathy of Prematurity Diagnosis
Chiang, M. F., Keenan, J. D., Starren, J. B., Du, Y. E., Schiff, W. M., Barile, G. R., Li, J., Johnson, R. A., Hess, D. J., & Flynn, J. T. (2006) · Archives of Ophthalmology · doi:10.1001/archopht.124.3.322 · Cited by 128
Color Doppler Imaging of Retinal Diseases
Dimitrova, G., & Kato, S. (2010) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2009.06.010 · Cited by 126
Optimal Filter Framework for Automated, Instantaneous Detection of Lesions in Retinal Images
Quellec, G., Russell, S. R., & Abràmoff, M. D. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2089383 · Cited by 125
Information Fusion for Diabetic Retinopathy CAD in Digital Color Fundus Photographs
Niemeijer, M., Abràmoff, M. D., & van Ginneken, B. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.2012029 · Cited by 125
Taylor, C. R., Merin, L. M., Salunga, A. M., Hepworth, J. T., Crutcher, T. D., O’Day, D. M., & Pilon, B. A. (2007) · Diabetes Care · doi:10.2337/dc06-1509 · Cited by 122
Automated localisation of retinal optic disk using Hough transform
Sekhar, S., Al‐Nuaimy, W., & Nandi, A. K. (2008) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2008.4541312 · Cited by 121
Automatic Optic Disc Detection From Retinal Images by a Line Operator
Lu, S., & Lim, J. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2086455 · Cited by 119
Nunes, S. G., Pires, I., Rosa, A. M., Duarte, L., Bernardes, R. C., & Cunha-Vaz, J. G. (2009) · Ophthalmologica · doi:10.1159/000213639 · Cited by 114
Self-citationAutomated Detection of Diabetic Retinopathy in a Fundus Photographic Screening Population
Larsen, N., Godt, J., Grunkin, M., Lund-Andersen, H., & Larsen, M. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0417 · Cited by 110
Vessel Boundary Delineation on Fundus Images Using Graph-Based Approach
Xu, X., Niemeijer, M., Song, Q., Milan Sonka, A., Garvin, M. K., Reinhardt, J. M., & Abràmoff, M. D. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2103566 · Cited by 108
Separation of the retinal vascular graph in arteries and veins based upon structural knowledge
Rothaus, K., Jiang, X., & Rhiem, P. (2008) · Image and Vision Computing · doi:10.1016/j.imavis.2008.02.013 · Cited by 106
Rudnisky, C. J., Hinz, B. J., TENNANT, M. T. S., de Leon, A. R., & Greve, M. D. J. (2002) · Ophthalmology · doi:10.1016/s0161-6420(01)00933-2 · Cited by 100
Image Registration for Digital Subtraction Angiography
Meijering, E. H. W., Zuiderveld, K. J., & Viergever, M. A. (1999) · International Journal of Computer Vision · doi:10.1023/a:1008074100927 · Cited by 94
Structure-Function Correlation of the Human Central Retina
Issa, P. C., Troeger, E., Finger, R. P., Holz, F. G., Wilke, R. G. H., & Scholl, H. P. N. (2010) · PLoS ONE · doi:10.1371/journal.pone.0012864 · Cited by 93
Nonproliferative retinopathy in diabetes type 2. Initial stages and characterization of phenotypes
Cunha-Vaz, J. G., & Bernardes, R. C. (2004) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2004.07.004 · Cited by 91
Self-citationEvaluation of a new non‐mydriatic digital camera for detection of diabetic retinopathy
Massin, P., Erginay, A., Mehidi, A. B., Vicaut, É., Quentel, G., Victor, Z., Marre, M., Guillausseau, P.-J., & Gaudric, A. (2003) · Diabetic Medicine · doi:10.1046/j.1464-5491.2003.01002.x · Cited by 91
A novel approach to diagnose diabetes based on the fractal characteristics of retinal images
Cheng, S.-C., & Huang, Y. (2003) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2003.813792 · Cited by 90
Chromatic aberration correction of the human eye for retinal imaging in the near infrared
Fernández, E. J. M., Unterhuber, A., Považay, B., Hermann, B. M., Artal, P., & Drexler, W. (2006) · Optics Express · doi:10.1364/oe.14.006213 · Cited by 90
Lobo, C. L., Bernardes, R. C., & Cunha-Vaz, J. G. (2000) · Archives of Ophthalmology · doi:10.1001/archopht.118.10.1364 · Cited by 87
Self-citationGrading of age-related maculopathy for epidemiological studies
van Leeuwen, R., Chakravarthy, U., Vingerling, J. R., Brussee, C., Hooghart, A. J., Mulder, P. G. H., & de Jong, P. T. V. M. (2003) · Ophthalmology · doi:10.1016/s0161-6420(03)00501-3 · Cited by 85
Pirbhai, A., Sheidow, T., & Hooper, P. L. (2005) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2004.09.077 · Cited by 83
The scanning laser ophthalmoscope—a review of its role in bioscience and medicine
Sharp, P. F., Manivannan, A., Xu, H., & Forrester, J. V. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/7/001 · Cited by 82
Robust Methodology for Fractal Analysis of the Retinal Vasculature
Azemin, M. Z. C., Kumar, D., Wong, T. Y., Kawasaki, R., Mitchell, P. L. R., & Wang, J. J. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2076322 · Cited by 80
Becker, D. E., Can, A., Turner, J. N., Tanenbaum, H. L., & Roysam, B. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.650362 · Cited by 75
Digital imaging of the optic nerve head: monoscopic and stereoscopic analysis
Morgan, J. E., Sheen, N. J. L., North, R. V., Choong, Y., & Ansari, E. (2005) · British Journal of Ophthalmology · doi:10.1136/bjo.2004.046169 · Cited by 74
Roy, M. S. (2011) · Archives of Ophthalmology · doi:10.1001/archophthalmol.2010.340 · Cited by 72
Vickerman, M. B., Keith, P. A., McKay, T. L., Gedeon, D. J., Watanabe, M., Montano, M. M., Karunamuni, G. H., Kaiser, P. K., Sears, J. E., Ebrahem, Q., et al. (2009) · The Anatomical Record · doi:10.1002/ar.20862 · Cited by 72
Hubbard, L. D., Danis, R. P., Neider, M. W., Thayer, D. W., Wabers, H. D., White, J. K., Pugliese, A. J., & Pugliese, M. F. (2008) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.07-1267 · Cited by 71
Unsupervised curvature-based retinal vessel segmentation
Garg, S., Sivaswamy, J., & Chandra, S. (2007) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2007.356859 · Cited by 69
Computer Classification of Nonproliferative Diabetic Retinopathy
Lee, S. C., Lee, E. T., Wang, Y., Klein, R., Kingsley, R. M., & Warn, A. (2005) · Archives of Ophthalmology · doi:10.1001/archopht.123.6.759 · Cited by 69
Retinal vessel tree segmentation using a deformable contour model
Pernas, L. E., Carreira, M. J., Penedo, M. G., & Ortega, M. (2008) · Proceedings - International Conference on Pattern Recognition/Proceedings/International Conference on Pattern Recognition · doi:10.1109/icpr.2008.4761762 · Cited by 67
Telemedicine and Diabetic Retinopathy: Moving Beyond Retinal Screening
Silva, P. S. (2011) · Archives of Ophthalmology · doi:10.1001/archophthalmol.2010.365 · Cited by 66
Bayesian detection of the fovea in eye fundus angiographies
Ibáñez, M. V., & Simó, A. (1999) · Pattern Recognition Letters · doi:10.1016/s0167-8655(98)00137-8 · Cited by 66
Lobo, C. L., Bernardes, R. C., Figueira, J. P., de Abreu, J. R. F., & Cunha-Vaz, J. G. (2004) · Archives of Ophthalmology · doi:10.1001/archopht.122.2.211 · Cited by 63
Self-citationLawrence, M. G. (2004) · PubMed Central · Cited by 62
Is screening with digital imaging using one retinal view adequate?
Herbert, H. M., Jordan, K., & Flanagan, D. W. (2003) · Eye · doi:10.1038/sj.eye.6700409 · Cited by 61
Segmentation of macular fluorescein angiographies. A statistical approach
Simó, A., & de Ves, E. (2001) · Pattern Recognition · doi:10.1016/s0031-3203(00)00032-7 · Cited by 61
Computer-Assisted Microaneurysm Turnover in the Early Stages of Diabetic Retinopathy
Bernardes, R. C., Nunes, S. G., Pereira, I. L. L., Torrent, T., Rosa, A. M., Coelho, D., & Cunha-Vaz, J. G. (2009) · Ophthalmologica · doi:10.1159/000213638 · Cited by 60
Self-citationFundus autofluorescence imaging compared with different confocal scanning laser ophthalmoscopes
Bellmann, C., Rubin, G., Kabanarou, S. A., Bird, A. C., & Fitzke, F. (2003) · British Journal of Ophthalmology · doi:10.1136/bjo.87.11.1381 · Cited by 58
Blood-flow magnetic resonance imaging of the retina
Li, Y., Cheng, H., & Duong, T. Q. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.10.030 · Cited by 58
Fundus autofluorescence in the diagnosis of cystoid macular oedema
McBain, V. A., Forrester, J. V., & Lois, N. (2008) · British Journal of Ophthalmology · doi:10.1136/bjo.2007.129957 · Cited by 55
Mapping Retinal Fluorescein Leakage With Confocal Scanning Laser Fluorometry of the Human Vitreous
Lobo, C. L., Bernardes, R. C., Santos, F. J., & Cunha-Vaz, J. G. (1999) · Archives of Ophthalmology · doi:10.1001/archopht.117.5.631 · Cited by 55
Self-citationSensitivity and specificity of digital retinal imaging for screening diabetic retinopathy
Lopez‐Bastida, J., Cabrera‐Lopez, F., & Serrano‐Aguilar, P. (2007) · Diabetic Medicine · doi:10.1111/j.1464-5491.2007.02074.x · Cited by 53
Lim, J. I., LABREE, L. D., Nichols, T., & Cardenas, I. (2000) · Ophthalmology · doi:10.1016/s0161-6420(00)00057-9 · Cited by 52
Integrated Analysis of Vascular and Nonvascular Changes From Color Retinal Fundus Image Sequences
Narasimha-Iyer, H., Can, A., Roysam, B., Tanenbaum, H. L., & Majerovics, A. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.900807 · Cited by 50
Optical Coherence Tomography: Principles and Applications
Fujimoto, J. G. (2003) · The Review of Laser Engineering · doi:10.2184/lsj.31.635 · Cited by 50
Simultaneous OCT/SLO/ICG Imaging
Rosen, R. B., Hathaway, M. W., Rogers, J., Pedro, J., Garcia, P., Dobre, G. M., & Podoleanu, A. G. (2009) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.08-1855 · Cited by 46
Muramatsu, C., Hatanaka, Y., Tatsuhiko, I., Hara, T., & Fujita, H. (2010) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.843898 · Cited by 44
Colour slides or digital photography in diabetes screening – a comparison
Henricsson, M., Karlsson, C., Ekholm, L., Kaikkonen, P., Sellman, A., Steffert, E., & Tyrberg, M. (2000) · Acta Ophthalmologica Scandinavica · doi:10.1034/j.1600-0420.2000.078002164.x · Cited by 42
Cornforth, D. J., Jelinek, H. F., Cree, M. J., Leandro, J. J. G., Soares, J. V. B., & Junior, R. M. C. (2009) · Studies in computational intelligence · doi:10.1007/978-3-540-95978-6_12 · Cited by 41
Feasibility Study on Computer-Aided Screening for Diabetic Retinopathy
Singalavanija, A., Supokavej, J., Bamroongsuk, P., Sinthanayothin, C., Phoojaruenchanachai, S., & Kongbunkiat, V. (2006) · Japanese Journal of Ophthalmology · doi:10.1007/s10384-005-0328-3 · Cited by 40
Retinal image analysis: preprocessing and feature extraction
Marrugo, A. G., & Millán, M. S. (2011) · Journal of Physics Conference Series · doi:10.1088/1742-6596/274/1/012039 · Cited by 39
Diabetic retinal screening in the UK
Mead, A., Burnett, S., & Davey, C. C. (2001) · Journal of the Royal Society of Medicine · doi:10.1177/014107680109400307 · Cited by 39
Salem, N. M., Salem, S. A., & Nandi, A. K. (2007) · Zenodo (CERN European Organization for Nuclear Research) · doi:10.5281/zenodo.40292 · Cited by 38
Zeimer, R. C., Zou, S., Meeder, T., Quinn, K. P., & Vitale, S. (2002) · PubMed · Cited by 37
Scholl, H. P. N., Dandekar, S. S., Pető, T., Bunce, C., Xing, W., Jenkins, S. A., & Bird, A. C. (2004) · Ophthalmology · doi:10.1016/j.ophtha.2003.05.003 · Cited by 36
Towards vessel characterisation in the vicinity of the optic disc in digital retinal images
Jelinek, H. F., Deaprdieu, C., Lucas, C., Cornforth, D. J., Huang, W. B., & Cree, M. J. (2005) · Cited by 36
Lin, G., Stewart, C. V., Roysam, B., Fritzsche, K. H., Yang, G., & Tanenbaum, H. L. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.820332 · Cited by 34
Schiffman, R. M., Jacobsen, G., Nussbaum, J. J., Desai, U. R., Carey, J. D., Glasser, D., Zimmer-Galler, I. E., Zeimer, R. C., & Goldberg, M. F. (2005) · Ophthalmic surgery, lasers & imaging retina · doi:10.3928/15428877-20050101-06 · Cited by 33
Sensitivity and specificity of digital retinal images in grading diabetic retinopathy
Saari, J. M., Summanen, P. A., Kivelä, T., & Saari, K. M. (2004) · Acta Ophthalmologica Scandinavica · doi:10.1111/j.1600-0420.2004.00240.x · Cited by 33
Tracking of Blood Vessels in Retinal Images Using Kalman Filter
Yedidya, T., & Hartley, R. I. (2008) · International Conference on Digital Image Computing: Techniques and Applications (DICTA) · doi:10.1109/dicta.2008.72 · Cited by 31
Automated analysis of retinal vascular network connectivity
Al-Diri, B., Hunter, A., STEEL, D. H., & Habib, M. (2010) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2009.12.013 · Cited by 30
In vivo characterization of ischemic retina in diabetic retinopathy
Reznicek, L. (2010) · Clinical ophthalmology · doi:10.2147/opth.s13850 · Cited by 29
Fundus photography for measurement of macular pigment density distribution in children.
Bour, L. J., Koo, L., Delori, F. C., Apkarian, P. A., & Fulton, A. B. (2002) · PubMed · Cited by 29
The effect of digital image resolution and compression on anterior eye imaging
Peterson, R. C. (2005) · British Journal of Ophthalmology · doi:10.1136/bjo.2004.062240 · Cited by 27
Mapping the Human Blood-Retinal Barrier Function
Bernardes, R. C., Dias, J. M. M., & Cunha-Vaz, J. G. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.839801 · Cited by 24
Self-citationSabti, K. A., Raizada, S., Wani, V. B., Ajmi, M. A., Gayed, I. I., & Sugathan, T. N. (2003) · Journal of Diabetes and its Complications · doi:10.1016/s1056-8727(03)00007-2 · Cited by 24
Chakravarthy, U., Walsh, A. C., Muldrew, A., Updike, P. G., Barbour, T., & Sadda, S. R. (2006) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.06-0493 · Cited by 23
Somani, R., TENNANT, M. T. S., Rudnisky, C. J., Weis, E., Ting, A., Eppler, J., Greve, M. D. J., Hinz, B. J., & de Leon, A. (2005) · Canadian Journal of Ophthalmology · doi:10.1016/s0008-4182(05)80072-9 · Cited by 21
Framme, C., Roider, J. B., Sachs, H. G., Brinkmann, R., & Gabel, V. (2005) · Current Medical Imaging Formerly Current Medical Imaging Reviews · doi:10.2174/1573405052952994 · Cited by 15
Retinal wall-to-lumen ratio: a new marker of endothelial function?
Cuspidi, C., & Sala, C. (2010) · Journal of Hypertension · doi:10.1097/hjh.0b013e328341c6b4 · Cited by 11
Vascular Tree Construction with Anatomical Realism for Retinal Images
Lin, K.-S., Tsai, C.-L., Sofka, M., Tsai, C.-H., Chen, S., & Lin, W.-Y. (2009) · IEEE International Conference on Bioinformatics and Bioengineering (BIBE) · doi:10.1109/bibe.2009.18 · Cited by 10
Assessment of Automated Screening for Treatment-Requiring Diabetic Retinopathy
Larsen, M., Gondolf, T., Godt, J., Jensen, M. S., Hartvig, N. V., Lund‐Andersen, H., & Larsen, N. B. (2007) · Current Eye Research · doi:10.1080/02713680701215587 · Cited by 10
Evaluation of Digital Fundus Images as a Diagnostic Method for Surveillance of Diabetic Retinopathy
Chun, D. W., Bauer, R. M., Ward, T. P., Dick, J. S. B., & Bower, K. S. (2007) · Military Medicine · doi:10.7205/milmed.172.4.405 · Cited by 9
Is digital retinal imaging alone sufficient as a screening tool for diabetic retinopathy?
Razvi, F., Illahi, W., & Ryder, R. E. J. (2002) · Practical Diabetes · doi:10.1002/pdi.398 · Cited by 4
Cited by
Deep Learning and Glaucoma Specialists
Phene, S., Dunn, R. C., Hammel, N., Liu, Y., Krause, J., Kitade, N., Schaekermann, M., Sayres, R., Wu, D. J., Bora, A., et al. (2019) · Ophthalmology · doi:10.1016/j.ophtha.2019.07.024 · Cited by 186
A mobile phone-based retinal camera for portable wide field imaging
Maamari, R. N., Keenan, J. D., Fletcher, D. A., & Margolis, T. P. (2014) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2013-303797 · Cited by 166
The Empirical Evidence for the Telemedicine Intervention in Diabetes Management
Bashshur, R. L., Shannon, G. W., Smith, B. R., & Woodward, M. A. (2015) · Telemedicine and e-Health · doi:10.1089/tmj.2015.0029 · Cited by 102
Metadata
- Authors
- Bernardes, R., Serranho, P., & Lobo, C.
- Venue
- Ophthalmologica
- Publisher
- S. Karger AG
- Published
- 2011
- Volume
- 226
- Issue
- 4
- Pages
- 161-181
- ISSN
- 0030-3755 (ISSN-L)
- 1423-0267
- OpenAlex
- W2116273337
- Cited by
- 207
- References
- 129
- FWCI
- 8.96
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.