CoChat

Influence of Fibrin Network Conformation and Fibrin Fiber Diameter on Fibrinolysis Speed: Dynamic and Structural Approaches by Confocal Microscopy

Collet, J. P., Park, D., Lesty, C., Soria, J., Soria, C., Montalescot, G., Weisel, J. W. · 2000 · Arteriosclerosis, Thrombosis, and Vascular Biology
Cited by 492

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

Abstract —Abnormal fibrin architecture is thought to be a determinant factor of hypofibrinolysis. However, because of the lack of structural knowledge of the process of fibrin digestion, relationships between fibrin architecture and hypofibrinolysis remain controversial. To elucidate further structural and dynamic changes occurring during fibrinolysis, cross-linked plasma fibrin was labeled with colloidal gold particles, and fibrinolysis was followed by confocal microscopy. Morphological changes were characterized at fibrin network and fiber levels. The observation of a progressive disaggregation of the fibrin fibers emphasizes that fibrinolysis proceeds by transverse cutting rather than by progressive cleavage uniformly around the fiber. Plasma fibrin clots with a tight fibrin conformation made of thin fibers were dissolved at a slower rate than those with a loose fibrin conformation made of thicker (coarse) fibers, although the overall fibrin content remained constant. Unexpectedly, thin fibers were cleaved at a faster rate than thick ones. A dynamic study of FITC–recombinant tissue plasminogen activator distribution within the fibrin matrix during the course of fibrinolysis showed that the binding front was broader in coarse fibrin clots and moved more rapidly than that of fine plasma fibrin clots. These dynamic and structural approaches to fibrin digestion at the network and the fiber levels reveal aspects of the physical process of clot lysis. Furthermore, these results provide a clear explanation for the hypofibrinolysis related to a defective fibrin architecture as described in venous thromboembolism and in premature coronary artery disease.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.atv.20.5.1354

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

Metadata

Authors
Collet, J. P., Park, D., Lesty, C., Soria, J., Soria, C., Montalescot, G., & Weisel, J. W.
Venue
Arteriosclerosis, Thrombosis, and Vascular Biology
Published
2000-05
Volume
20
Issue
5
Pages
1354-1361
ISSN
  • 1079-5642 (ISSN-L)
  • 1524-4636
OpenAlex
W2057007282
Cited by
492
References
13
FWCI
5.72
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.