Ultrasound-Targeted Microbubble Destruction Can Repeatedly Direct Highly Specific Plasmid Expression to the Heart
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Background— Noninvasive, tissue-specific delivery of therapeutic agents would be a valuable clinical tool. We have previously shown that ultrasound-targeted microbubble destruction can direct expression of an adenoviral reporter to the heart. The present study shows that this method can be applied to selectively deliver plasmid vectors to the heart. Methods and Results— We used albumin and lipid microbubbles containing plasmids with a luciferase transgene to target the heart in rats. After 4 days, organs were harvested and analyzed for reporter gene expression. In a second set of experiments, the hearts of rats treated with plasmids were harvested at various time points during a 4-week period. Both luciferase activity and mRNA concentrations were measured. Luciferase transfection with plasmids showed highly specific gene expression in the heart, with hardly any activity in control organs. Time course evaluation showed high transgene expression in the first 4 days, with a rapid decline thereafter. Repeated treatment produced a second peak of transgene expression with similar decay. Conclusions— Ultrasound-mediated destruction of microbubbles directs plasmid transgene expression to the heart with much greater specificity than viral vectors and can be regulated by repeated treatments. This noninvasive technique is a promising method for cardiac gene therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Skyba, D. M., Price, R. J., Linka, A. Z., Skalak, T. C., & Kaul, S. (1998) · Circulation · doi:10.1161/01.cir.98.4.290 · Cited by 474
Echocardiographic Destruction of Albumin Microbubbles Directs Gene Delivery to the Myocardium
Shohet, R. V., Chen, S., Zhou, Y.-T., Wang, Z., Meidell, R. S., Unger, R. H., & Grayburn, P. A. (2000) · Circulation · doi:10.1161/01.cir.101.22.2554 · Cited by 446
Self-citationVincent, K. A., Shyu, K.-G., Luo, Y., Magner, M., Tio, R. A., Jiang, C., Goldberg, M. A., Akita, G. Y., Gregory, R. J., & Isner, J. M. (2000) · Circulation · doi:10.1161/01.cir.102.18.2255 · Cited by 317
Isner, J. M. (2002) · Nature · doi:10.1038/415234a · Cited by 309
Mercadier, J.-J., & Logeart, D. (2002) · PubMed · Cited by 305
Schwarz, E. R., Speakman, M. T., Patterson, M., Hale, S. S., Isner, J. M., Kedes, L. H., & Kloner, R. A. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00522-2 · Cited by 272
Direct in vivo gene transfer into porcine myocardium using replication-deficient adenoviral vectors.
French, B. A., Mazur, W., Geske, R. S., & Bolli, R. (1994) · Circulation · doi:10.1161/01.cir.90.5.2414 · Cited by 241
Wickham, T. J. (2000) · Gene Therapy · doi:10.1038/sj.gt.3301115 · Cited by 236
Reynolds, P. N., Nicklin, S. A., Kaliberova, L., Boatman, B. G., Grizzle, W. E., Balyasnikova, I. V., Baker, A. H., Danilov, S. M., & Curiel, D. T. (2001) · Nature Biotechnology · doi:10.1038/nbt0901-838 · Cited by 225
Chen, S., Shohet, R. V., Bekeredjian, R., Frenkel, P., & Grayburn, P. A. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00627-2 · Cited by 212
Self-citationGene Delivery Using Ultrasound Contrast Agents
Unger, E. C., Hersh, E., Vannan, M., & McCreery, T. (2001) · Echocardiography · doi:10.1046/j.1540-8175.2001.00355.x · Cited by 170
Ultrasound Enhances Gene Expression of Liposomal Transfection
UNGER, E. C., McCREERY, T. P., & SWEITZER, R. H. (1997) · INVESTIGATIVE RADIOLOGY · doi:10.1097/00004424-199712000-00001 · Cited by 160
Shah, A. S., Lilly, R. E., Kypson, A. P., Tai, O., Hata, J. A., Pippen, A. M., Silvestry, S., Lefkowitz, R. J., Glower, D. D., & Koch, W. J. (2000) · Circulation · doi:10.1161/01.cir.101.4.408 · Cited by 129
Characterization of Physiologically Regulated Vectors for the Treatment of Ischemic Disease
Boast, K., Binley, K., Iqball, S., Price, T., Spearman, H., Kingsman, S. M., Kingsman, A. J., & Naylor, S. (1999) · Human Gene Therapy · doi:10.1089/10430349950017185 · Cited by 68
Cited by
Ultrasound Microbubble Contrast Agents: Fundamentals and Application to Gene and Drug Delivery
Ferrara, K., Pollard, R., & Borden, M. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095852 · Cited by 1,288
Microbubbles in ultrasound-triggered drug and gene delivery
Hernot, S., & Klibanov, A. L. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2008.03.005 · Cited by 990
Ultrasonic drug delivery – a general review
Pitt, W. G., Husseini, G. A., & Staples, B. J. (2004) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.1.1.37 · Cited by 621
Microbubble compositions, properties and biomedical applications
Sirsi, S. R., & Borden, M. A. (2009) · Bubble Science, Engineering & Technology · doi:10.1179/175889709x446507 · Cited by 594
Gene therapy and DNA delivery systems
Ibraheem, D., Elaissari, A., & Fessi, H. (2014) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2013.11.041 · Cited by 454
Metadata
- Authors
- Bekeredjian, R., Chen, S., Frenkel, P. A., Grayburn, P. A., & Shohet, R. V.
- Venue
- Circulation
- Published
- 2003-08-26
- Volume
- 108
- Issue
- 8
- Pages
- 1022-1026
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2099781987
- Cited by
- 321
- References
- 14
- FWCI
- 15.37
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.