The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Molecular Imaging of Angiogenesis in Early-Stage Atherosclerosis With α v β 3 -Integrin–Targeted Nanoparticles
Open accessAbstract
Background— Angiogenesis is a critical feature of plaque development in atherosclerosis and might play a key role in both the initiation and later rupture of plaques that lead to myocardial infarction and stroke. The precursory molecular or cellular events that initiate plaque growth and that ultimately contribute to plaque instability, however, cannot be detected directly with any current diagnostic modality. Methods and Results— Atherosclerosis was induced in New Zealand White rabbits fed 1% cholesterol for ≈80 days. α v β 3 -Integrin–targeted, paramagnetic nanoparticles were injected intravenously and provided specific detection of the neovasculature within 2 hours by routine magnetic resonance imaging (MRI) at a clinically relevant field strength (1.5 T). Increased angiogenesis was detected as a 47±5% enhancement in MRI signal averaged throughout the abdominal aortic wall among rabbits that received α v β 3 -targeted, paramagnetic nanoparticles. Pretreatment of atherosclerotic rabbits with α v β 3 -targeted, nonparamagnetic nanoparticles competitively blocked specific contrast enhancement of the α v β 3 -targeted paramagnetic agent. MRI revealed a pattern of increased α v β 3 -integrin distribution within the atherosclerotic wall that was spatially heterogeneous along both transverse and longitudinal planes of the abdominal aorta. Histology and immunohistochemistry confirmed marked proliferation of angiogenic vessels within the aortic adventitia, coincident with prominent, neointimal proliferation among cholesterol-fed, atherosclerotic rabbits in comparison with sparse incidence of neovasculature in the control animals. Conclusions— This molecular imaging approach might provide a method for defining the burden and evolution of atherosclerosis in susceptible individuals as well as responsiveness of individual patients to antiatherosclerotic therapies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“nanoemulsions functionalized to detect plaque neovascularization133 (FIG. 5d)”
From Perspectives and opportunities for nanomedicine in the management of atherosclerosis (2011) · cites this paper as [133]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Integrin αvβ3 antagonists promote tumor regression by inducing apoptosis of angiogenic blood vessels
Brooks, P. C., Montgomery, A. M. P., Rosenfeld, M., Reisfeld, R. A., Hu, T., Klier, G., & Cheresh, D. A. (1994) · Cell · doi:10.1016/0092-8674(94)90007-8 · Cited by 2,262
Sudden Cardiac Death in the United States, 1989 to 1998
Zheng, Z., Croft, J. B., Giles, W. H., & Mensah, G. A. (2001) · Circulation · doi:10.1161/hc4301.098254 · Cited by 1,597
Moulton, K. S., Heller, E., Konerding, M. A., Flynn, E., Palinski, W., & Folkman, J. (1999) · Circulation · doi:10.1161/01.cir.99.13.1726 · Cited by 688
Ruehm, S. G., Corot, C., VOGT, P. R., Kolb, S., & Debatin, J. F. (2001) · Circulation · doi:10.1161/01.cir.103.3.415 · Cited by 606
Flacke, S., Fischer, S., Scott, M. J., Fuhrhop, R. J., Allen, J. S., McLean, M., Winter, P., Sicard, G. A., Gaffney, P. J., Wickline, S. A., et al. (2001) · Circulation · doi:10.1161/hc3601.094303 · Cited by 515
Self-citationWater diffusion compartmentation and anisotropy at high b values in the human brain
Clark, C. A., & Bihan, D. L. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200012)44:6 · Cited by 432
Self-citationContrast‐enhanced high resolution MRI for atherosclerotic carotid artery tissue characterization
Yuan, C., Kerwin, W. S., Ferguson, M. S., Polissar, N. L., Zhang, S., Cai, J., & Hatsukami, T. S. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10030 · Cited by 422
A Novel Site-Targeted Ultrasonic Contrast Agent With Broad Biomedical Application
Lanza, G. M., Wallace, K. D., Scott, M. J., Cacheris, W. P., Abendschein, D. R., Christy, D. H., Sharkey, A. M., Miller, J. G., Gaffney, P. J., & Wickline, S. A. (1996) · Circulation · doi:10.1161/01.cir.94.12.3334 · Cited by 406
Self-citationKerwin, W. S., Hooker, A. C., Spilker, M. E., Vicini, P., Ferguson, M. S., Hatsukami, T. S., & Yuan, C. (2003) · Circulation · doi:10.1161/01.cir.0000048145.52309.31 · Cited by 353
Lanza, G. M., Yu, X., Winter, P. M., Abendschein, D. R., Karukstis, K. K., Scott, M. J., Chinen, L. K., Fuhrhop, R. W., Scherrer, D. E., & Wickline, S. A. (2002) · Circulation · doi:10.1161/01.cir.0000044020.27990.32 · Cited by 288
Self-citation
Research works printed but not linked: 9
Cited by
Sorted by citations
Items 401–500 of 697
Lee, S.-J., Olsen, B. N., Schlesinger, P. H., & Baker, N. (2010) · The Journal of Physical Chemistry B · doi:10.1021/jp103228c · Cited by 17
Lavín, B., Phinikaridou, A., Lorrio, S., Zaragoza, C., & Botnar, R. M. (2015) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.114.002417 · Cited by 17
Hémadou, A., Laroche‐Traineau, J., Antoine, S., Mondon, P., Fontayne, A., Priol, Y. L., Claverol, S., Sanchez, S., Cérutti, M., Ottonès, F., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-33382-2 · Cited by 19
Gertz, S. D., Cherukuri, P., Bodmann, B. G., Gladish, G. W., Wilner, W. T., Conyers, J. L., Aboshady, I., Madjid, M., Vela, D. C., Lukovenkov, S., et al. (2005) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2005.08.034 · Cited by 17
Cardiovascular Molecular Imaging With Fluorine-19 MRI: The Road to the Clinic
van Heeswijk, R. B., Bauer, W. R., Bönner, F., Janjic, J. M., Mulder, W. J. M., Schreiber, W., Schwitter, J., & Flögel, U. (2023) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.123.014742 · Cited by 16
Molecular magnetic resonance imaging of atherosclerotic vessel wall disease
Nörenberg, D., Ebersberger, H. U., Diederichs, G., Hamm, B., Botnar, R. M., & Makowski, M. R. (2015) · European Radiology · doi:10.1007/s00330-015-3881-2 · Cited by 16
Dobrucki, L. W., Meoli, D. F., Hu, J., Sadeghi, M. M., & Sinusas, A. J. (2009) · PubMed · Cited by 16
Molecular and Nonmolecular Magnetic Resonance Coronary and Carotid Imaging
Hajhosseiny, R., Bahaei, T. S., Prieto, C., & Botnar, R. M. (2019) · Arteriosclerosis Thrombosis and Vascular Biology · doi:10.1161/atvbaha.118.311754 · Cited by 16
Graf, K., Dietrich, T., Tachezy, M., Scholle, F.-D., Licha, K., Stawowy, P., Gräfe, M., Hauff, P., & Fleck, E. (2008) · Molecular Imaging · doi:10.2310/7290.2008.0009 · Cited by 16
Héroux, J., Gharib, A. M., Danthi, N. S., Cecchini, S., Jacques Ohayon, A., & Pettigrew, R. I. (2009) · Molecular Imaging and Biology · doi:10.1007/s11307-009-0242-z · Cited by 15
Li, Z., Huang, H., Huang, L., Du, L., Sun, Y., & Duan, Y. (2017) · International Journal of Molecular Sciences · doi:10.3390/ijms18040815 · Cited by 15
Galis, Z. S., & Lessner, S. M. (2009) · Trends in Cardiovascular Medicine · doi:10.1016/j.tcm.2009.06.001 · Cited by 15
Quantifying progression and regression of thrombotic risk in experimental atherosclerosis
Palekar, R. U., Jallouk, A. P., Goette, M., Chen, J., Myerson, J. W., Allen, J. S., Akk, A. M., Yang, L., Tu, Y., Miller, M. J., et al. (2015) · The FASEB Journal · doi:10.1096/fj.14-269084 · Cited by 15
Self-citationLenz, T., Nicol, P., Castellanos, M. I., Engel, L., Lahmann, A. L., Alexiou, C., & Joner, M. (2020) · Molecules · doi:10.3390/molecules25051029 · Cited by 16
Cardiovascular Magnetic Resonance Imaging in Small Animals
Botnar, R. M., & Makowski, M. R. (2011) · Progress in molecular biology and translational science · doi:10.1016/b978-0-12-394596-9.00008-1 · Cited by 15
Iwaki, S., Hokamura, K., Ogawa, M., Takehara, Y., Muramatsu, Y., Yamane, T., Hirabayashi, K., Morimoto, Y., Hagisawa, K., Nakahara, K., et al. (2014) · Organic & Biomolecular Chemistry · doi:10.1039/c4ob01270d · Cited by 16
Novel Imaging Techniques for Quantifying Overall Atherosclerotic Burden
Ibáñez, B., Pinero, A., Orejas, M., & Badimón, J. J. (2007) · Revista Española de Cardiología (English Edition) · doi:10.1016/s1885-5857(07)60154-6 · Cited by 15
Coronary Computed Tomography and Magnetic Resonance Imaging
Kantor, B., Nagel, E. C., Schoenhagen, P., Barkhausen, J., & Gerber, T. C. (2009) · Current Problems in Cardiology · doi:10.1016/j.cpcardiol.2008.12.002 · Cited by 14
Du, X., Zhang, Y., Chen, L., Mi, B., You, Q., Xu, Y., Pan, D., Wan, W., Yang, M., & Yu, C. (2018) · Contrast Media & Molecular Imaging · doi:10.1155/2018/8194678 · Cited by 14
Design of Nanovectors for Therapy and Imaging of Cardiovascular Diseases
Eniola‐Adefeso, O., Heslinga, M. J., & Porter, T. M. (2012) · Methodist DeBakey Cardiovascular Journal · doi:10.14797/mdcj-8-1-13 · Cited by 14
The role of noninvasive imaging in promoting cardiovascular health
Fuster, V., & Vahl, T. P. (2010) · Journal of Nuclear Cardiology · doi:10.1007/s12350-010-9264-9 · Cited by 14
Strategies to reverse atherosclerosis: An imaging perspective
Thompson, J. B., Blaha, M. J., Resar, J. R., Blumenthal, R. S., & Desai, M. Y. (2008) · Current Treatment Options in Cardiovascular Medicine · doi:10.1007/s11936-008-0049-2 · Cited by 14
Engineering imaging probes and molecular machines for nanomedicine
Tong, S., Cradick, T. J., Ma, Y., Dai, Z., & Bao, G. (2012) · Science China Life Sciences · doi:10.1007/s11427-012-4380-1 · Cited by 15
Reflection from bound microbubbles at high ultrasound frequencies
Couture, O., Sprague, M., Chérin, E., Burns, P. N., & Foster, F. S. (2009) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2009.1070 · Cited by 14
Baroldi, G., Bigi, R., & Cortigiani, L. (2004) · Cardiovascular Ultrasound · doi:10.1186/1476-7120-2-29 · Cited by 14
Molecular cardiovascular imaging
Dobrucki, L. W., & Sinusas, A. J. (2005) · Current Cardiology Reports · doi:10.1007/s11886-005-0025-3 · Cited by 14
Hughes, M. S., Marsh, J. N., Arbeit, J. M., Neumann, R., Fuhrhop, R. W., Lanza, G., & Wickline, S. A. (2006) · Proceedings/Proceedings - IEEE Ultrasonics Symposium · doi:10.1109/ultsym.2005.1602928 · Cited by 14
Self-citationKorystova, A. F., Emel’yanov, M. O., Kublik, L. N., Levitman, M. K., Shaposhnikova, V. V., Kim, Y. A., & Korystov, Y. N. (2011) · AGE · doi:10.1007/s11357-011-9282-9 · Cited by 13
Efficacy of Pt-modified TiO(2) nanoparticles in cardiac cells.
Mallik, A., Bryan, S., Puukila, S., Chen, A., & Khaper, N. (2011) · Europe PMC (PubMed Central) · Cited by 12
Improved quantitative19F MR molecular imaging with flip angle calibration andB1-mapping compensation
Goette, M., Lanza, G. M., Caruthers, S. D., & Wickline, S. A. (2014) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24812 · Cited by 13
Self-citationAmsallem, M., Saito, T., Tada, Y., Dash, R., & McConnell, M. V. (2016) · Circulation Journal · doi:10.1253/circj.cj-16-0224 · Cited by 14
Li, Z., Wang, Q., Jing, H., Luo, X., Du, L., & Duan, Y. (2021) · ACS Applied Nano Materials · doi:10.1021/acsanm.1c02009 · Cited by 12
Marjanović, M., Nguyen, F. T., Ahmad, A., Huang, P., Suslick, K. S., & Boppart, S. A. (2018) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2018.2856582 · Cited by 12
Ju, Y. (2020) · Optical and Quantum Electronics · doi:10.1007/s11082-020-02574-4 · Cited by 12
Nijdam, A. J., Nicholson, T. R., Shapiro, J. P., Smith, B. R., Heverhagen, J. T., Schmalbrock, P., Knopp, M. V., Kebbel, A., Wang, D., & Lee, S. (2009) · Current Nanoscience · doi:10.2174/157341309787314601 · Cited by 12
“Endothelial Progenitor Cells” as a Therapeutic Strategy in Cardiovascular Disease
Kränkel, N., Lüscher, T. F., & Landmesser, U. (2011) · Current Vascular Pharmacology · doi:10.2174/157016112798829832 · Cited by 13
Hu, L., Zhang, L., Chen, J., Lanza, G. M., & Wickline, S. A. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22656 · Cited by 12
Self-citationWick, M. C., Chemelli-Steingruber, I. E., & Kremser, C. (2011) · Springer eBooks · doi:10.1007/978-3-7091-0338-8_29 · Cited by 12
Analysis of in situ and ex vivo αVß3 integrin expression during experimental carotid atherogenesis
Liu, N., & Yao, Y. (2012) · International Journal of Nanomedicine · doi:10.2147/ijn.s28065 · Cited by 12
Soman, N. R., Marsh, J. N., Hughes, M. S., Lanza, G., & Wickline, S. A. (2006) · IEEE Transactions on NanoBioscience · doi:10.1109/tnb.2006.875052 · Cited by 12
Self-citationAa, A., Thurner, G. C., Wallnöfer, E. A., Klammsteiner, N., Kremser, C., Talasz, H., Mrakovcic, M., Fröhlich, E., Jaschke, W. R., & Debbage, P. L. (2010) · Histochemistry and Cell Biology · doi:10.1007/s00418-010-0726-6 · Cited by 12
Imaging the Cellular Biology of the Carotid Plaque
U‐King‐Im, J. M., Tang, T. Y., Moustafa, R. R., Baron, J., Warburton, E. A., & Gillard, J. H. (2007) · International Journal of Stroke · doi:10.1111/j.1747-4949.2007.00123.x · Cited by 12
Non-invasive detection of vulnerable coronary plaque
Sharif, F. (2011) · World Journal of Cardiology · doi:10.4330/wjc.v3.i7.219 · Cited by 11
Liu, X., Gao, R., Chen, C., Li, X., Chen, Y., Chen, Y., Liang, H., Xiao, M., Dai, L., Qiu, S., et al. (2022) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-022-05911-9 · Cited by 11
Structural and functional imaging by MRI
Botnar, R. M., & Nagel, E. C. (2008) · Basic Research in Cardiology · doi:10.1007/s00395-008-0706-3 · Cited by 11
Maleimidyl magnetic nanoplatform for facile molecular MRI
Heo, D., Lee, E., Ku, M., Hwang, S., Kim, B., Park, Y., Lee, Y. H., Huh, Y., Haam, S., Cheong, J., et al. (2014) · Nanotechnology · doi:10.1088/0957-4484/25/27/275102 · Cited by 11
Nanotechnology and its Relationship to Interventional Radiology. Part I: Imaging
Power, S., Slattery, M. M., & Lee, M. J. (2010) · CardioVascular and Interventional Radiology · doi:10.1007/s00270-010-9961-4 · Cited by 11
Sun, G., Chen, J., Ding, Y., Wren, J. D., Xu, F., Lu, L., Wang, Y., Wang, D., & Zhang, X. A. (2021) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2021.630471 · Cited by 10
Effects of 1-year tofacitinib therapy on angiogenic biomarkers in rheumatoid arthritis
Kerekes, G., Czókolyová, M., Hamar, A., Pusztai, A., Tajti, G., Katkó, M., Végh, E., Pethő, Z., Bodnár, N., Horváth, Á., et al. (2023) · Rheumatology · doi:10.1093/rheumatology/kead502 · Cited by 10
MR Contrast Agents for Cardiac Imaging
Ni, Y. (2011) · Medical radiology · doi:10.1007/174_2011_360 · Cited by 10
Multifunctional Polymeric Nanosystems for Tumor-Targeted Delivery
Magadala, P., van Vlerken, L. E., Shahiwala, A., & Amiji, M. M. (2008) · Fundamental biomedical technologies · doi:10.1007/978-0-387-76554-9_2 · Cited by 11
Wang, K., Pan, D., Schmieder, A. H., Senpan, A., Caruthers, S. D., Cui, G., Allen, J. S., Zhang, H., Shen, B., & Lanza, G. M. (2015) · Nanomedicine Nanotechnology Biology and Medicine · doi:10.1016/j.nano.2014.12.008 · Cited by 10
Self-citationChemically modifiable fluorinated copolymer nanoparticles for 19F‐MRI contrast enhancement
Bailey, M. M., Kline, S. R., Anderson, M. D., Staymates, J. L., & Berkland, C. J. (2012) · Journal of Applied Polymer Science · doi:10.1002/app.36889 · Cited by 10
Will Molecular Optical Imaging Have Clinically Important Roles in Stroke Management, and How?
Lee, D. K., Nahrendorf, M., Schellingerhout, D., & Kim, D. (2010) · Journal of Clinical Neurology · doi:10.3988/jcn.2010.6.1.10 · Cited by 10
Peptides, Multimers and Polymers
Dijkraaf, I., & Wester, H. J. (2008) · Handbook of experimental pharmacology · doi:10.1007/978-3-540-77496-9_4 · Cited by 10
Hughes, M. S., Marsh, J. N., Woodson, A. K., Lacey, E. K., Carradine, C., Lanza, G., & Wickline, S. A. (2006) · Proceedings/Proceedings - IEEE Ultrasonics Symposium · doi:10.1109/ultsym.2005.1602872 · Cited by 10
Self-citationSmall, G. R., & Ruddy, T. D. (2011) · Journal of Nuclear Cardiology · doi:10.1007/s12350-011-9385-9 · Cited by 9
In vivo molecular imaging of vascular stress
Wick, M. C., Kremser, C., Frischauf, S., & Wick, G. (2008) · Cell Stress and Chaperones · doi:10.1007/s12192-008-0043-3 · Cited by 9
Identification of interleukin-2 for imaging atherosclerotic inflammation
Fayad, Z. A., Amirbekian, V., Toussaint, J., & Fuster, V. (2005) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-005-1981-y · Cited by 9
MR molecular imaging of angiogenesis using targeted perfluorocarbon nanoparticles.
Caruthers, S. D., Winter, P. M., Wickline, S. A., Lanza, G. M., & Keupp, J. (2010) · PubMed · Cited by 8
Self-citationReview Article on Targeted Polymeric Nanoparticles: An Overview
Kumar, G., Dhyani, A., & Kothiyal, P. (2015) · American Journal of Advanced Drug Delivery · Cited by 8
Aguirre, M. Á., Long, K. D., Li, N., Manoto, S. L., & Cunningham, B. T. (2018) · Chemosensors · doi:10.3390/chemosensors6020013 · Cited by 8
Pathobiology and Mechanisms of Atherosclerosis
Quillard, T., & Croce, K. (2014) · Springer eBooks · doi:10.1007/978-3-319-09268-3_1 · Cited by 8
Molecular MRI of atherosclerotic plaque with targeted contrast agents
Sosnovik, D. E., & Caravan, P. D. (2009) · Current Cardiovascular Imaging Reports · doi:10.1007/s12410-009-0012-y · Cited by 8
Modern methods for imaging carotid atheroma
Trivedi, R. A., Gillard, J. H., & Kirkpatrick, P. J. (2008) · British Journal of Neurosurgery · doi:10.1080/02688690802007891 · Cited by 8
Mahmood, U., & Josephson, L. (2005) · Proceedings of the IEEE · doi:10.1109/jproc.2005.844264 · Cited by 8
Recent advances in targeted nanoparticle drug delivery systems for ischaemic stroke
Li, X., Wang, Q., Fang, Q., Xu, J., Han, B., Chen, Y. Q., Yao, W., Ye, S., & Wang, B. (2023) · Materials Advances · doi:10.1039/d3ma00472d · Cited by 7
Nanoparticles as Contrast Agents for MRI of Atherosclerotic Lesions
Frias, J. C., Lipinski, M. J., Albelda, M. T., Ibáñez, B., Soriano, C., García‐España, E., Jiménez‐Borreguero, L. J., & Badimón, J. J. (2008) · Clinical medicine Cardiology · doi:10.4137/cmc.s642 · Cited by 7
Emerging Molecular Targets for Intravascular Imaging of High-Risk Plaques
Kim, J. W., & Jaffer, F. A. (2010) · Current Cardiovascular Imaging Reports · doi:10.1007/s12410-010-9028-6 · Cited by 7
Atherosclerosis and Thrombosis
Choudhury, R. P. (2007) · Topics in Magnetic Resonance Imaging · doi:10.1097/rmr.0b013e3181598dd8 · Cited by 7
Noninvasive Imaging of Plaque Inflammation
Kerwin, W. S. (2010) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2010.09.004 · Cited by 7
Molecular Imaging of the Heart
Boutagy, N. E., Fehér, A., Alkhalil, I., Umoh, N., & Sinusas, A. J. (2019) · Comprehensive physiology · doi:10.1002/cphy.c180007 · Cited by 8
Fluorine (19F) MRI to Measure Renal Oxygen Tension and Blood Volume: Experimental Protocol
Hu, L., Pan, H., & Wickline, S. A. (2021) · Methods in molecular biology · doi:10.1007/978-1-0716-0978-1_31 · Cited by 6
Self-citationMolecular Imaging: A Primer for Interventionalists and Imagers
Wang, D. S., Dake, M. D., Park, J. M., & Kuo, M. (2009) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2009.04.042 · Cited by 6
Cardiovascular Nanomedicine: Challenges and Opportunities
Godin, B., Hu, Y., Francesca, S. L., & Mauro Ferrari, B. (2012) · Humana Press eBooks · doi:10.1007/978-1-61779-906-8_9 · Cited by 6
Boekhorst, B. C. M. T., Bovens, S. M., van de Kolk, C. W. A., Cramer, M. J., Doevendans, P. A., ten Hove, M., van der Weerd, L., Poelmann, R. E., Strijkers, G. J., Pasterkamp, G., et al. (2010) · NMR in Biomedicine · doi:10.1002/nbm.1514 · Cited by 6
Identification of a cytoplasmic linker protein as a potential target for neovascularization
Xie, S., Dong, B., Sun, X., Tala, He, X., Zhou, J., Liu, M., & Li, D. (2014) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2014.01.009 · Cited by 6
Recent Advances in Visualizing Vulnerable Plaque: Focus on Noninvasive Molecular Imaging
Bala, G., & Cosyns, B. (2014) · Current Cardiology Reports · doi:10.1007/s11886-014-0520-5 · Cited by 6
Montet-Abou, K., Viallon, M., Hyacinthe, J., Delattre, B. M. A., Vallée, J., Didier, D., Croisille, P., & Montet, X. (2010) · International Journal of Obesity · doi:10.1038/ijo.2010.242 · Cited by 5
Nanomaterial based Magnetic Resonance Imaging of Cancer
Asampille, G., Brahmkhatri, V. P., & Atreya, H. S. (2014) · NOT FOUND REPOSITORY (Indian Institute of Science Bangalore) · Cited by 6
Molecular Imaging of Coronary Atherosclerosis
Jaffer, F. A., & Libby, P. (2014) · Contemporary cardiology · doi:10.1007/978-1-4939-0572-0_14 · Cited by 6
Chemokine and Chemokine Receptor Analysis
Islam, S. A., Medoff, B. D., & Luster, A. D. (2016) · ASM Press eBooks · doi:10.1128/9781555818722.ch37 · Cited by 6
Vargas, I., Grabau, R. P., Chen, J., Weinheimer, C. J., Kovács, A. D., Dominguez‐Viqueira, W., Mitchell, A., Wickline, S. A., & Pan, H. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms24087333 · Cited by 5
Self-citationMR and Targeted Molecular MRI of Vulnerable Plaques
Yang, J., Yang, H., Cao, L., & Li, S. (2012) · Interventional Neurology · doi:10.1159/000346767 · Cited by 5
Magnetic resonance imaging in vascular biology☆
Voehringer, M. C., Sechtem, U. P., & Friedrich, M. G. (2008) · Artery Research · doi:10.1016/j.artres.2008.01.002 · Cited by 5
Cardiovascular Molecular Imaging with Contrast Ultrasound: Principles and Applications
Shim, C. Y., & Lindner, J. R. (2014) · Korean Circulation Journal · doi:10.4070/kcj.2014.44.1.1 · Cited by 5
Chapter 4 Active Targeting of Perfluorocarbon Nanoemulsions
Temme, S., Grapentin, C., Güden-Silber, T., & Flögel, U. (2016) · Pan Stanford Publishing eBooks · doi:10.1201/9781315364605-5 · Cited by 5
Fuster, V., & Sanz, J. (2007) · Journal of the American Society of Hypertension · doi:10.1016/j.jash.2006.11.005 · Cited by 5
Advances in contrast media for vascular imaging of atherosclerosis
Young, V. E. L., Degnan, A. J., & Gillard, J. H. (2011) · Imaging in Medicine · doi:10.2217/iim.11.23 · Cited by 5
Activated αvβ3 Integrin Targeting in Injury-Induced Vascular Remodeling
Sadeghi, M. M., & Bender, J. R. (2007) · Trends in Cardiovascular Medicine · doi:10.1016/j.tcm.2006.07.003 · Cited by 5
Ismail, M. Y., Hossain, M. F., Karim, M. F., & Shekhar, H. U. (2015) · Advances in Bioscience and Biotechnology · doi:10.4236/abb.2015.69064 · Cited by 5
Importance of Receptor-targeted Systems in the Battle Against Atherosclerosis
Rosàs, E., Sobenin, I. A., Orekhov, A. N., Edelman, E. R., & Balcells, M. (2013) · Current Pharmaceutical Design · doi:10.2174/1381612811319330010 · Cited by 5
Molecular Cardiovascular Magnetic Resonance: Current Status and Future Prospects
Bender, Y. Y., Pfeifer, A., Ebersberger, H. U., Diederichs, G., Höppe, P., Hamm, B., Botnar, R. M., & Makowski, M. R. (2016) · Current Cardiology Reports · doi:10.1007/s11886-016-0719-8 · Cited by 5
Noninvasive Molecular Imaging of Mouse Atherosclerosis
McAteer, M. A., & Choudhury, R. P. (2015) · Methods in molecular biology · doi:10.1007/978-1-4939-2929-0_4 · Cited by 5
Gibbons, R. J., & Araoz, P. A. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.05.065 · Cited by 5
Miserus, R.-J. J. H. M., Heeneman, S., van Engelshoven, J. M. A., Kooi, M. E., & Daemen, M. J. A. P. (2006) · Drug Discovery Today Technologies · doi:10.1016/j.ddtec.2006.06.008 · Cited by 5
Imaging after vascular gene therapy
Manninen, H. I., & Yang, X. (2005) · European Journal of Radiology · doi:10.1016/j.ejrad.2005.03.019 · Cited by 5
Wickline, S. A. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.01.009 · Cited by 5
Self-citationPolymeric Nanoencapsulation of Indocyanine green for Photodynamic Therapy Technique
Saboktakin, M. R. (2019) · American Journal of Biomedical Science & Research · doi:10.34297/ajbsr.2019.03.000630 · Cited by 4
Mangarova, D. B., Kaufmann, J. O., Brangsch, J., Kader, A., Möckel, J., Heyl, J. L., Verlemann, C., Adams, L. C., Ludwig, A., Reimann, C., et al. (2025) · Investigative Radiology · doi:10.1097/rli.0000000000001152 · Cited by 4
Metadata
- Authors
- Winter, P. M., Morawski, A. M., Caruthers, S. D., Fuhrhop, R. W., Zhang, H., Williams, T. A., Allen, J. S., Lacy, E. K., Robertson, J. D., Lanza, G. M., & Wickline, S. A.
- Affiliations
- Washington University in St. Louis (US)
- ORCID
- Venue
- Circulation
- Published
- 2003-11-04
- Volume
- 108
- Issue
- 18
- Pages
- 2270-2274
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2101681003
- Cited by
- 696
- References
- 24
- Citations by year
- 2026: 3 · 2025: 1 · 2024: 4 · 2023: 10 · 2022: 8 · 2021: 10 · 2020: 17 · 2019: 24 · 2018: 19 · 2017: 17 · 2016: 22 · 2015: 30 · 2014: 44 · 2013: 36 · 2012: 47
- FWCI
- 31.66
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Circulation (publishedVersion)
- PubMed (publishedVersion)
- Funders
- American Heart Association
- Bristol-Myers Squibb
- University of Bristol
- National Institutes of Health (5r01hl042950-17)
- U.S. Public Health Service (N01-C0-07121)
- National Heart, Lung, and Blood Institute (HL 59865, R01HL059865, HL 42950)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
- Life Sciences › Immunology and Microbiology › Immunology › Atherosclerosis and Cardiovascular Diseases
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cerebrovascular and Carotid Artery Diseases
- Keywords
- atherosclerosis, angiogenesis, alpha v beta 3 integrin, molecular imaging, paramagnetic nanoparticles, neovasculature, aortic plaque, neointimal proliferation, plaque vulnerability, cholesterol-fed rabbits, MRI contrast agents
- MeSH terms
- Animals, Aorta, Arteriosclerosis, Cholesterol, Dietary, Contrast Media, Disease Models, Animal, Immunohistochemistry, Magnetic Resonance Imaging, Male, Neovascularization, Pathologic, Particle Size, Rabbits, Sensitivity and Specificity, Integrin alphaVbeta3
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review