The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Molecular Imaging of Angiogenesis in Early-Stage Atherosclerosis With α v β 3 -Integrin–Targeted Nanoparticles
Open accessAbstract
Background— Angiogenesis is a critical feature of plaque development in atherosclerosis and might play a key role in both the initiation and later rupture of plaques that lead to myocardial infarction and stroke. The precursory molecular or cellular events that initiate plaque growth and that ultimately contribute to plaque instability, however, cannot be detected directly with any current diagnostic modality. Methods and Results— Atherosclerosis was induced in New Zealand White rabbits fed 1% cholesterol for ≈80 days. α v β 3 -Integrin–targeted, paramagnetic nanoparticles were injected intravenously and provided specific detection of the neovasculature within 2 hours by routine magnetic resonance imaging (MRI) at a clinically relevant field strength (1.5 T). Increased angiogenesis was detected as a 47±5% enhancement in MRI signal averaged throughout the abdominal aortic wall among rabbits that received α v β 3 -targeted, paramagnetic nanoparticles. Pretreatment of atherosclerotic rabbits with α v β 3 -targeted, nonparamagnetic nanoparticles competitively blocked specific contrast enhancement of the α v β 3 -targeted paramagnetic agent. MRI revealed a pattern of increased α v β 3 -integrin distribution within the atherosclerotic wall that was spatially heterogeneous along both transverse and longitudinal planes of the abdominal aorta. Histology and immunohistochemistry confirmed marked proliferation of angiogenic vessels within the aortic adventitia, coincident with prominent, neointimal proliferation among cholesterol-fed, atherosclerotic rabbits in comparison with sparse incidence of neovasculature in the control animals. Conclusions— This molecular imaging approach might provide a method for defining the burden and evolution of atherosclerosis in susceptible individuals as well as responsiveness of individual patients to antiatherosclerotic therapies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“nanoemulsions functionalized to detect plaque neovascularization133 (FIG. 5d)”
From Perspectives and opportunities for nanomedicine in the management of atherosclerosis (2011) · cites this paper as [133]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Integrin αvβ3 antagonists promote tumor regression by inducing apoptosis of angiogenic blood vessels
Brooks, P. C., Montgomery, A. M. P., Rosenfeld, M., Reisfeld, R. A., Hu, T., Klier, G., & Cheresh, D. A. (1994) · Cell · doi:10.1016/0092-8674(94)90007-8 · Cited by 2,262
Sudden Cardiac Death in the United States, 1989 to 1998
Zheng, Z., Croft, J. B., Giles, W. H., & Mensah, G. A. (2001) · Circulation · doi:10.1161/hc4301.098254 · Cited by 1,597
Moulton, K. S., Heller, E., Konerding, M. A., Flynn, E., Palinski, W., & Folkman, J. (1999) · Circulation · doi:10.1161/01.cir.99.13.1726 · Cited by 688
Ruehm, S. G., Corot, C., VOGT, P. R., Kolb, S., & Debatin, J. F. (2001) · Circulation · doi:10.1161/01.cir.103.3.415 · Cited by 606
Flacke, S., Fischer, S., Scott, M. J., Fuhrhop, R. J., Allen, J. S., McLean, M., Winter, P., Sicard, G. A., Gaffney, P. J., Wickline, S. A., et al. (2001) · Circulation · doi:10.1161/hc3601.094303 · Cited by 515
Self-citationWater diffusion compartmentation and anisotropy at high b values in the human brain
Clark, C. A., & Bihan, D. L. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200012)44:6 · Cited by 432
Self-citationContrast‐enhanced high resolution MRI for atherosclerotic carotid artery tissue characterization
Yuan, C., Kerwin, W. S., Ferguson, M. S., Polissar, N. L., Zhang, S., Cai, J., & Hatsukami, T. S. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10030 · Cited by 422
A Novel Site-Targeted Ultrasonic Contrast Agent With Broad Biomedical Application
Lanza, G. M., Wallace, K. D., Scott, M. J., Cacheris, W. P., Abendschein, D. R., Christy, D. H., Sharkey, A. M., Miller, J. G., Gaffney, P. J., & Wickline, S. A. (1996) · Circulation · doi:10.1161/01.cir.94.12.3334 · Cited by 406
Self-citationKerwin, W. S., Hooker, A. C., Spilker, M. E., Vicini, P., Ferguson, M. S., Hatsukami, T. S., & Yuan, C. (2003) · Circulation · doi:10.1161/01.cir.0000048145.52309.31 · Cited by 353
Lanza, G. M., Yu, X., Winter, P. M., Abendschein, D. R., Karukstis, K. K., Scott, M. J., Chinen, L. K., Fuhrhop, R. W., Scherrer, D. E., & Wickline, S. A. (2002) · Circulation · doi:10.1161/01.cir.0000044020.27990.32 · Cited by 288
Self-citation
Research works printed but not linked: 9
Cited by
Sorted by citations
Items 101–200 of 697
Brott, T. G., Halperin, J. L., Abbara, S., Bacharach, J. M., Barr, J. D., Bush, R. L., Cates, C. U., Creager, M. A., Fowler, S. A., Friday, G. H., et al. (2011) · Circulation · doi:10.1161/cir.0b013e31820d8c98 · Cited by 119
Cell labeling and tracking for experimental models using Magnetic Resonance Imaging
Himmelreich, U., & Dresselaers, T. (2009) · Methods · doi:10.1016/j.ymeth.2009.03.020 · Cited by 117
Matter, C. M., Schuler, P. K., Alessi, P., Meier, P., Ricci, R., Zhang, D., Halin, C., Castellani, P., Zardi, L., Hofer, C. K., et al. (2004) · Circulation Research · doi:10.1161/01.res.0000150373.15149.ff · Cited by 117
Mushenkova, N. V., Summerhill, V. I., Zhang, D., Romanenko, E. B., Grechko, A. V., & Orekhov, A. N. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21082992 · Cited by 122
Vasa vasorum imaging: A new window to the clinical detection of vulnerable atherosclerotic plaques
CARLIER, S. G., Kakadiaris, I. A., Dib, N., Vavuranakis, M., O’Malley, S. M., Gul, K. M., Hartley, C. J., Metcalfe, R. W., Mehran, R., Stefanadis, C., et al. (2005) · Current Atherosclerosis Reports · doi:10.1007/s11883-005-0040-2 · Cited by 116
Dayton, P. A., Pearson, D., Clark, J., Simon, S. I., Schumann, P. A., Zutshi, R., Matsunaga, T. O., & Ferrara, K. W. (2004) · Molecular Imaging · doi:10.1162/1535350041464883 · Cited by 116
Molecular imaging of cardiac remodelling after myocardial infarction
Curley, D., Lavín, B., Shah, A. M., & Botnar, R. M. (2018) · Basic Research in Cardiology · doi:10.1007/s00395-018-0668-z · Cited by 112
Leuschner, F., & Nahrendorf, M. (2011) · Circulation Research · doi:10.1161/circresaha.110.232678 · Cited by 110
Contrast Harmonic Intravascular Ultrasound
Goertz, D. E., Frijlink, M. E., Tempel, D., van Damme, L. C. A., Krams, R., Schaar, J. A., ten Cate, F. J., Serruys, P. W. J. C., de Jong, N., & van der Steen, A. F. W. (2006) · Investigative Radiology · doi:10.1097/01.rli.0000229773.11715.da · Cited by 109
Targeting Integrins in Cancer Nanomedicine: Applications in Cancer Diagnosis and Therapy
Wu, P., Opadele, A. E., Onodera, Y., & Nam, J. (2019) · Cancers · doi:10.3390/cancers11111783 · Cited by 110
van Tilborg, G. A. F., Vucic, E., Strijkers, G. J., Cormode, D. P., Mani, V., Skajaa, T., Reutelingsperger, C. P. M., Fayad, Z. A., Mulder, W. J. M., & Nicolay, K. (2010) · Bioconjugate Chemistry · doi:10.1021/bc100091q · Cited by 114
Low-Density Lipoprotein Nanoparticles as Magnetic Resonance Imaging Contrast Agents
Corbin, I. R., Li, H., Chen, J., Lund‐Katz, S., Zhou, R., Glickson, J. D., & Zheng, G. (2006) · Neoplasia · doi:10.1593/neo.05835 · Cited by 108
Nanotechnology-mediated targeting of tumor angiogenesis
Banerjee, D., Harfouche, R., & Sengupta, S. (2011) · Vascular Cell · doi:10.1186/2045-824x-3-3 · Cited by 108
Small Animal Imaging with Magnetic Resonance Microscopy
Driehuys, B., Nouls, J. C., Badea, A., Bucholz, E., Ghaghada, K. B., Petiet, A., & Hedlund, L. W. (2008) · ILAR Journal · doi:10.1093/ilar.49.1.35 · Cited by 106
Simnick, A. J., Valencia, C. A., Liu, R., & Chilkoti, A. (2010) · ACS Nano · doi:10.1021/nn901732h · Cited by 106
Ferumoxtran-10–Enhanced MRI of the Hypercholesterolemic Rabbit Aorta
Hyafil, F., Laissy, J., Mazighi, M., Tchétché, D., Louedec, L., Adle‐Biassette, H., Chillon, S., Hénin, D., Jacob, M., Letourneur, D., et al. (2005) · Arteriosclerosis Thrombosis and Vascular Biology · doi:10.1161/01.atv.0000194098.82677.57 · Cited by 106
Kosuge, H., Sherlock, S. P., Kitagawa, T., Dash, R., Robinson, J. T., Dai, H., & McConnell, M. V. (2012) · Journal of the American Heart Association · doi:10.1161/jaha.112.002568 · Cited by 106
Atherosclerotic plaque development and instability: A dual role for VEGF
Holm, P. W., Slart, R. H. J. A., Zeebregts, C. J., Hillebrands, J., & Tio, R. A. (2008) · Annals of Medicine · doi:10.1080/07853890802516507 · Cited by 106
Quantitative magnetic resonance fluorine imaging: today and tomorrow
Chen, J., Lanza, G. M., & Wickline, S. A. (2010) · Wiley Interdisciplinary Reviews Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.87 · Cited by 106
Self-citationNon-invasive anatomic and functional imaging of vascular inflammation and unstable plaque
Camici, P. G., Rimoldi, O. E., Gaemperli, O., & Libby, P. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs067 · Cited by 105
Vulnerable Plaque: Definition, Diagnosis, and Treatment
Moreno, P. (2009) · Cardiology Clinics · doi:10.1016/j.ccl.2009.09.008 · Cited by 106
Single nanoparticle detection using photonic crystal enhanced microscopy
Zhuo, Y., Hu, H., Chen, W., Lu, M., Tian, L., Yu, H., Long, K. D., Chow, E. K. C., King, W. P., Singamaneni, S., et al. (2014) · The Analyst · doi:10.1039/c3an02295a · Cited by 102
Molecular Imaging in Atherosclerosis, Thrombosis, and Vascular Inflammation
Choudhury, R. P., & Fisher, E. A. A. (2009) · Arteriosclerosis Thrombosis and Vascular Biology · doi:10.1161/atvbaha.108.165498 · Cited by 105
Molecular targeting with peptides or peptide-polymer conjugates: just a question of size?
Wester, H., & Kessler, H. (2005) · PubMed · Cited by 102
Nanoparticle-Based Systems for T1-Weighted Magnetic Resonance Imaging Contrast Agents
Zhu, D., Liu, F., Ma, L., Liu, D., & Wang, Z. (2013) · International Journal of Molecular Sciences · doi:10.3390/ijms140510591 · Cited by 103
Tran, T. D., Caruthers, S. D., Hughes, M. S., Marsh, J. N., Cyrus, T., Winter, P. M., Neubauer, A. M., Wickline, S. A., & Lanza, G. M. (2007) · PubMed Central · Cited by 100
Self-citationImaging Atherosclerosis and Vulnerable Plaque
Sadeghi, M. M., Glover, D. K., Lanza, G. M., Fayad, Z. A., & Johnson, L. L. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.068163 · Cited by 99
Self-citationCaruthers, S. D., Neubauer, A. M., Hockett, F. D., Lamerichs, R. M. J. N., Winter, P. M., Scott, M. J., Gaffney, P. J., Wickline, S. A., & Lanza, G. M. (2006) · Investigative Radiology · doi:10.1097/01.rli.0000199281.60135.6a · Cited by 98
Self-citationNear-Infrared Fluorescence Imaging of Tumor Integrin αvβ3 Expression with Cy7-Labeled RGD Multimers
Wu, Y., Cai, W., & Chen, X. S. (2006) · Molecular Imaging and Biology · doi:10.1007/s11307-006-0041-8 · Cited by 101
Park, K., Hong, H.-Y., Moon, H. J., Lee, B.-H., Kim, I., Kwon, I. C., & Rhee, K. (2008) · Journal of Controlled Release · doi:10.1016/j.jconrel.2008.03.019 · Cited by 97
MYERSON, J., HE, L., LANZA, G., TOLLEFSEN, D., & WICKLINE, S. (2011) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2011.04339.x · Cited by 96
Self-citationImaging of stem cells using MRI
Kraitchman, D. L., & Bulte, J. W. M. (2008) · Basic Research in Cardiology · doi:10.1007/s00395-008-0704-5 · Cited by 94
Burtéa, C., Laurent, S., Murariu, O., Rattat, D., Toubeau, G., Verbruggen, A., Vansthertem, D., Elst, L. V., & Müller, R. N. (2008) · Cardiovascular Research · doi:10.1093/cvr/cvm115 · Cited by 93
The Role of Periadventitial Fat in Atherosclerosis
Vela, D. C., Buja, L. M., Madjid, M., Burke, A., Naghavi, M., Willerson, J. T., Casscells, S. W., & Litovsky, S. H. (2007) · Archives of Pathology & Laboratory Medicine · doi:10.5858/2007-131-481-tropfi · Cited by 93
Nanomedicine Strategies for Molecular Targets with Mri and Optical Imaging
Pan, D., Caruthers, S. D., Chen, J., Winter, P. M., Senpan, A., Schmieder, A. H., Wickline, S. A., & Lanza, G. M. (2010) · Future Medicinal Chemistry · doi:10.4155/fmc.10.5 · Cited by 92
Self-citationNeubauer, A. M., Myerson, J. W., Caruthers, S. D., Hockett, F. D., Winter, P. M., Chen, J., Gaffney, P. J., Robertson, J. D., Lanza, G. M., & Wickline, S. A. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21750 · Cited by 92
Self-citationTheragnostics for tumor and plaque angiogenesis with perfluorocarbon nanoemulsions
Lanza, G., Winter, P. M., Caruthers, S. D., Hughes, M. S., Hu, G., Schmieder, A. H., & Wickline, S. A. (2010) · Angiogenesis · doi:10.1007/s10456-010-9166-0 · Cited by 91
Self-citationFan, Z., Sun, Y., Chen, D., Tay, D., Chen, W., Deng, C. X., & Fu, J. (2013) · Scientific Reports · doi:10.1038/srep02176 · Cited by 91
Islam, T., & Josephson, L. (2009) · Cancer Biomarkers · doi:10.3233/cbm-2009-0615 · Cited by 89
Imaging of Angiogenesis: Clinical Techniques and Novel Imaging Methods
Provenzale, J. M. (2006) · American Journal of Roentgenology · doi:10.2214/ajr.06.0280 · Cited by 88
Xue, S., Yang, H., Qiao, J., Pu, F., Jiang, J., Hubbard, K., Hekmatyar, K., Langley, J. A., Salarian, M., Long, R. C., et al. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1423021112 · Cited by 87
Chen, W., Cormode, D. P., Vengrenyuk, Y., Herránz, B., Feig, J. E., Klink, A., Mulder, W. J. M., Fisher, E. A. A., & Fayad, Z. A. (2013) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2012.06.016 · Cited by 87
Vascular endothelial growth factors in cardiovascular medicine
Testa, U., Pannitteri, G., & Condorelli, G. (2008) · Journal of Cardiovascular Medicine · doi:10.2459/jcm.0b013e3283117d37 · Cited by 88
Chen, W., Vucic, E., Leupold, E., Mulder, W. J. M., Cormode, D. P., Briley-Saebo, K. C., Barazza, A., Fisher, E. A. A., Dathe, M., & Fayad, Z. A. (2008) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.257 · Cited by 86
Fan, Z., Chen, D., & Deng, C. X. (2013) · Journal of Controlled Release · doi:10.1016/j.jconrel.2013.05.039 · Cited by 88
Cardiovascular molecular imaging: an overview
Saraste, A., Nekolla, S. G., & Schwaiger, M. (2009) · Cardiovascular Research · doi:10.1093/cvr/cvp209 · Cited by 89
Atherosclerosis and Matrix Metalloproteinases: Experimental Molecular MR Imaging in Vivo
Amirbekian, V., Aguinaldo, J. G. S., Amirbekian, S., Hyafil, F., Vucic, E., Sirol, M., Weinreb, D. B., Greneur, S. L., Lancelot, E., Corot, C., et al. (2009) · Radiology · doi:10.1148/radiol.2511080539 · Cited by 86
Hindy, G., Tyrrell, D. J., Vasbinder, A. L., Wei, C., Presswalla, F., Wang, H., Blakely, P. K., Ozel, A. B., Graham, S. E., Holton, G. H., et al. (2022) · Journal of Clinical Investigation · doi:10.1172/jci158788 · Cited by 89
Cai, W. (2007) · Frontiers in bioscience · doi:10.2741/2386 · Cited by 86
α v β 3 –Targeted nanotherapy suppresses inflammatory arthritis in mice
Zhou, H.-F., Chan, H., Wickline, S. A., Lanza, G. M., & Pham, C. T. N. (2009) · The FASEB Journal · doi:10.1096/fj.09-129874 · Cited by 86
Self-citationApplication of nanoparticles on diagnosis and therapy in gliomas.
Hernández-Pedro, N. Y., Rangel-López, E., Magaña-Maldonado, R., de la Cruz, V. P., Santamaría del Angel, A., Pineda, B., & Sotelo, J. (2013) · BioMed Research International · doi:10.1155/2013/351031 · Cited by 84
Zhang, Y., Güallar, E., Qiao, Y., & Wasserman, B. A. (2014) · Arteriosclerosis Thrombosis and Vascular Biology · doi:10.1161/atvbaha.113.302075 · Cited by 83
Leary, S. P., Liu, C. Y., & Apuzzo, M. L. J. (2006) · Neurosurgery · doi:10.1227/01.neu.0000216793.45952.ed · Cited by 81
Vascular targeting of nanoparticles for molecular imaging of diseased endothelium
Atukorale, P. U., Covarrubias, G., Bauer, L., & Karathanasis, E. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.09.006 · Cited by 82
Pereira, G. A. L., Peters, J. A., Paz, F. A. A., Rocha, J., & Geraldes, C. F. G. C. (2010) · Inorganic Chemistry · doi:10.1021/ic9025014 · Cited by 78
Kim, M., Sahu, A., Kim, G. B., Nam, G., Um, W., Shin, S., Jeong, Y. Y., Kim, I., Kim, K., Kwon, I. C., et al. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.11.033 · Cited by 80
Waters, E. A., & Wickline, S. A. (2008) · Basic Research in Cardiology · doi:10.1007/s00395-008-0711-6 · Cited by 77
Self-citationEarly in vivo assessment of angiostatic therapy efficacy by molecular MRI
Mulder, W. J. M., van der Schaft, D. W. J., Hautvast, P. A. I., Strijkers, G. J., Koning, G. A., Storm, G., Mayo, K. H., Griffioen, A. W., & Nicolay, K. (2007) · The FASEB Journal · doi:10.1096/fj.06-6791com · Cited by 76
Wilensky, R. L., Song, H. K., & Ferrari, V. A. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.11.048 · Cited by 75
Theranostics and contrast agents for magnetic resonance imaging
Jeong, Y., Hwang, H. S., & Na, K. (2018) · Biomaterials Research · doi:10.1186/s40824-018-0130-1 · Cited by 76
Polymer‐based therapeutics: nanoassemblies and nanoparticles for management of atherosclerosis
Lewis, D. R., Kamisoglu, K., York, A. W., & Moghe, P. V. (2011) · Wiley Interdisciplinary Reviews Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.145 · Cited by 74
Significance of intraplaque neovascularisation for vulnerability: optical coherence tomography study
Tian, J., Hou, J., Xing, L., Kim, S., Yonetsu, T., Kato, K., Lee, H., Zhang, S., Yu, B., & Jang, I. (2012) · Heart · doi:10.1136/heartjnl-2012-302445 · Cited by 73
1H/19F Magnetic Resonance Molecular Imaging with Perfluorocarbon Nanoparticles
Lanza, G. M., Winter, P. M., Neubauer, A. M., Caruthers, S. D., Hockett, F. D., & Wickline, S. A. (2005) · Current topics in developmental biology/Current Topics in Developmental Biology · doi:10.1016/s0070-2153(05)70003-x · Cited by 73
Self-citationRademakers, T., Douma, K., Hackeng, T. M., Post, M. J., Sluimer, J. C., Daemen, M. J. A. P., Biessen, E. A. L., Heeneman, S., & van Zandvoort, M. A. M. J. (2012) · Arteriosclerosis Thrombosis and Vascular Biology · doi:10.1161/atvbaha.112.300087 · Cited by 72
Mühlen, C. V. Z., Peter, K., Ali, Z. A., Schneider, J. E., McAteer, M. A., Neubauer, S., Channon, K. M., Bode, C., & Choudhury, R. P. (2008) · Journal of Vascular Research · doi:10.1159/000135660 · Cited by 71
Molecular Body Imaging: MR Imaging, CT, and US. Part II. Applications
Kircher, M. F., & Willmann, J. K. (2012) · Radiology · doi:10.1148/radiol.12111703 · Cited by 76
Nanoparticles for Optical Molecular Imaging of Atherosclerosis
Douma, K., Prinzen, L., Slaaf, D. W., Reutelingsperger, C. P. M., Biessen, E. A. L., Hackeng, T. M., Post, M. J., & van Zandvoort, M. A. M. J. (2009) · Small · doi:10.1002/smll.200801079 · Cited by 72
Emerging nanomedicine opportunities with perfluorocarbon nanoparticles
Winter, P. M., Cai, K., Caruthers, S. D., Wickline, S. A., & Lanza, G. M. (2007) · Expert Review of Medical Devices · doi:10.1586/17434440.4.2.137 · Cited by 70
Self-citationWaters, E. A., Chen, J., Allen, J. S., Zhang, H., Lanza, G. M., & Wickline, S. A. (2008) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-10-43 · Cited by 71
Self-citationFluorine polymer probes for magnetic resonance imaging: quo vadis?
Jirák, D., Gálisová, A., Kolouchová, K., Babuka, D., & Hrubý, M. (2018) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-018-0724-6 · Cited by 69
Multifunctional agents for concurrent imaging and therapy in cardiovascular disease
McCarthy, J. R. (2010) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2010.07.004 · Cited by 73
Keupp, J., Rahmer, J., Graesslin, I., Mazurkewitz, P., Schaeffter, T., Lanza, G. M., Wickline, S. A., & Caruthers, S. D. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22877 · Cited by 68
Self-citationNMR Transversal Relaxivity of Suspensions of Lanthanide Oxide Nanoparticles
Norek, M., Pereira, G. A. L., Geraldes, C. F. G. C., Denkova, A. G., Zhou, W., & Peters, J. A. (2007) · The Journal of Physical Chemistry C · doi:10.1021/jp072288l · Cited by 68
Nanoparticle pharmacokinetic profiling in vivo using magnetic resonance imaging
Neubauer, A. M., Sim, H., Winter, P. M., Caruthers, S. D., Williams, T. A., Robertson, J. D., Sept, D., Lanza, G. M., & Wickline, S. A. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21795 · Cited by 68
Self-citationNanoparticles as magnetic resonance imaging contrast agents for vascular and cardiac diseases
Chen, W., Cormode, D. P., Fayad, Z. A., & Mulder, W. J. M. (2010) · Wiley Interdisciplinary Reviews Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.114 · Cited by 67
Gibbons, R. J., & Araoz, P. A. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.08.050 · Cited by 68
High-performance nanostructured MR contrast probes
Hu, F., Joshi, H. M., Dravid, V. P., & Meade, T. J. (2010) · Nanoscale · doi:10.1039/c0nr00173b · Cited by 67
Non-invasive assessment of vessel morphology and function in tumors by magnetic resonance imaging
Kiessling, F. M., Jugold, M., Woenne, E. C., & Brix, G. (2007) · European Radiology · doi:10.1007/s00330-006-0566-x · Cited by 67
Razavian, M., Tavakoli, S., Zhang, J., Nie, L., Dobrucki, L. W., Sinusas, A. J., Azure, M. T., Robinson, S. P., & Sadeghi, M. M. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.092379 · Cited by 67
Nanomedicine Opportunities for Cardiovascular Disease with Perfluorocarbon Nanoparticles
Lanza, G. M., Winter, P. M., Caruthers, S. D., Hughes, M. S., Cyrus, T., Marsh, J. N., Neubauer, A. M., Partlow, K. C., & Wickline, S. A. (2006) · Nanomedicine · doi:10.2217/17435889.1.3.321 · Cited by 67
Self-citationRecent Advances in 19 Fluorine Magnetic Resonance Imaging with Perfluorocarbon Emulsions
Schmieder, A. H., Caruthers, S. D., Keupp, J., Wickline, S. A., & Lanza, G. M. (2015) · Engineering · doi:10.15302/j-eng-2015103 · Cited by 67
Self-citationImaging Biomarkers in Atherosclerosis Trials
Tardif, J., Lesage, F., Harel, F., Roméo, P., & Pressacco, J. (2011) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.110.962001 · Cited by 68
Gd nanoparticulates: from magnetic resonance imaging to neutron capture therapy
Sharma, P., Brown, S. C., Walter, G. A., Santra, S., Scott, E. W., Ichikawa, H., Fukumori, Y., & Moudgil, B. M. (2007) · Advanced Powder Technology · doi:10.1163/156855207782515030 · Cited by 66
Studies of nanoparticle delivery with in vitro bio-engineered microtissues
Sun, M., Lee, J., Chen, Y., & Hoshino, K. (2020) · Bioactive Materials · doi:10.1016/j.bioactmat.2020.06.016 · Cited by 67
Liposome‐enhanced MRI of neointimal lesions in the ApoE‐KO mouse
Mulder, W. J. M., Douma, K., Koning, G. A., van Zandvoort, M. A. M. J., Lutgens, E., Daemen, M. J. A. P., Nicolay, K., & Strijkers, G. J. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20883 · Cited by 66
Self-Assembled Thermoresponsive Polymeric Nanogels for 19F MR Imaging
Kolouchová, K., Sedláček, O., Jirák, D., Babuka, D., Blahut, J., Kotek, J., Vít, M., Trousil, J., Konefał, R., Janoušková, O., et al. (2018) · Biomacromolecules · doi:10.1021/acs.biomac.8b00812 · Cited by 65
Magnetic Nanoparticles for Early Detection of Cancer by Magnetic Resonance Imaging
Lin, W., Hyeon, T., Lanza, G. M., Zhang, M., & Meade, T. J. (2009) · MRS Bulletin · doi:10.1557/mrs2009.120 · Cited by 66
Self-citationFabrication of RNA 3D Nanoprisms for Loading and Protection of Small RNAs and Model Drugs
Khisamutdinov, E. F., Jasinski, D. L., Li, H. Z., Zhang, K., Chiu, W., & Guo, P. (2016) · Advanced Materials · doi:10.1002/adma.201603180 · Cited by 65
Recent advances on nanoparticle-based therapies for cardiovascular diseases
Soumya, R. S., & Raghu, K. G. (2022) · Journal of Cardiology · doi:10.1016/j.jjcc.2022.02.009 · Cited by 68
Yang, X., Zhu, M. J., Sreejayan, N., Ren, J. T., & Du, . (2005) · Molecules and Cells · doi:10.1016/s1016-8478(23)13226-2 · Cited by 64
Cerebrovascular MRI: a review of state‐of‐the‐art approaches, methods and techniques
MacDonald, M. E., & Frayne, R. (2015) · NMR in Biomedicine · doi:10.1002/nbm.3322 · Cited by 63
Multimodality Tumor Imaging Targeting Integrin α v β 3
Cai, W., Gambhir, S. S., & Chen, X. S. (2005) · BioTechniques · doi:10.2144/000112091 · Cited by 63
Kitagawa, T., Kosuge, H., Uchida, M., Dua, M. M., 飯田, 泰., Dalman, R. L., Douglas, T., & McConnell, M. V. (2011) · Molecular Imaging and Biology · doi:10.1007/s11307-011-0495-1 · Cited by 62
Doiron, A. L., Chu, K. S., Ali, A., & Brannon‐Peppas, L. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0710205105 · Cited by 62
Tsiapa, I., Efthimiadou, E. Κ., Fragogeorgi, E. A., Loudos, G. K., Varvarigou, A. D., Bouziotis, P., Kordas, G. C., Mihailidis, D. N., Nikiforidis, G. C., Xanthopoulos, S., et al. (2014) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2014.07.032 · Cited by 63
Nanoimmunotherapy to treat ischaemic heart disease
Duivenvoorden, R., Senders, M. L., van Leent, M. M. T., Pérez‐Medina, C., Nahrendorf, M., Fayad, Z. A., & Mulder, W. J. M. (2018) · Nature Reviews Cardiology · doi:10.1038/s41569-018-0073-1 · Cited by 62
Sirol, M., Moreno, P., Purushothaman, K., Vucic, E., Amirbekian, V., Weinmann, H., Muntner, P., Fuster, V., & Fayad, Z. A. (2009) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.108.801712 · Cited by 61
Southworth, R., Kaneda, M. M., Chen, J., Zhang, L., Zhang, H., Yang, X., Razavi, R., Lanza, G. M., & Wickline, S. A. (2009) · Nanomedicine Nanotechnology Biology and Medicine · doi:10.1016/j.nano.2008.12.002 · Cited by 61
Self-citationC-MALISA (cellular magnetic-linked immunosorbent assay), a new application of cellular ELISA for MRI
Burtéa, C., Laurent, S., Roch, A., Elst, L. V., & Müller, R. N. (2005) · Journal of Inorganic Biochemistry · doi:10.1016/j.jinorgbio.2005.02.009 · Cited by 61
Zhou, H.-F., Yan, H., Senpan, A., Wickline, S. A., Pan, D., Lanza, G. M., & Pham, C. T. N. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.08.005 · Cited by 61
Self-citation
Metadata
- Authors
- Winter, P. M., Morawski, A. M., Caruthers, S. D., Fuhrhop, R. W., Zhang, H., Williams, T. A., Allen, J. S., Lacy, E. K., Robertson, J. D., Lanza, G. M., & Wickline, S. A.
- Affiliations
- Washington University in St. Louis (US)
- ORCID
- Venue
- Circulation
- Published
- 2003-11-04
- Volume
- 108
- Issue
- 18
- Pages
- 2270-2274
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2101681003
- Cited by
- 696
- References
- 24
- Citations by year
- 2026: 3 · 2025: 1 · 2024: 4 · 2023: 10 · 2022: 8 · 2021: 10 · 2020: 17 · 2019: 24 · 2018: 19 · 2017: 17 · 2016: 22 · 2015: 30 · 2014: 44 · 2013: 36 · 2012: 47
- FWCI
- 31.66
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Circulation (publishedVersion)
- PubMed (publishedVersion)
- Funders
- American Heart Association
- Bristol-Myers Squibb
- University of Bristol
- National Institutes of Health (5r01hl042950-17)
- U.S. Public Health Service (N01-C0-07121)
- National Heart, Lung, and Blood Institute (HL 59865, R01HL059865, HL 42950)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
- Life Sciences › Immunology and Microbiology › Immunology › Atherosclerosis and Cardiovascular Diseases
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cerebrovascular and Carotid Artery Diseases
- Keywords
- atherosclerosis, angiogenesis, alpha v beta 3 integrin, molecular imaging, paramagnetic nanoparticles, neovasculature, aortic plaque, neointimal proliferation, plaque vulnerability, cholesterol-fed rabbits, MRI contrast agents
- MeSH terms
- Animals, Aorta, Arteriosclerosis, Cholesterol, Dietary, Contrast Media, Disease Models, Animal, Immunohistochemistry, Magnetic Resonance Imaging, Male, Neovascularization, Pathologic, Particle Size, Rabbits, Sensitivity and Specificity, Integrin alphaVbeta3
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review