Covered Stent Septal Ablation for Hypertrophic Obstruction Cardiomyopathy
The DOI matches its Crossref record.
Abstract
Fifer et al 1 report a case of hypertrophic obstructive cardiomyopathy in which a covered stent was implanted in the left anterior descending artery to occlude the first septal branch after an unsuccessful attempt to cannulate it.Recurrence of symptoms was associated with collateralization from the right coronary artery of the occluded septal branch.We think this case is of special interest to the interventional cardiologist because it can be analogized to treatment of the complex bifurcation lesion.First, it demonstrates that the myocardium supplied by an occluded side branch during intervention may be protected by a collateral. 2 Second, it raises the concern, especially with the use of GpIIb/IIIa inhibitor, that in the rare case of a side branch perforation after percutaneous coronary intervention in a patient in whom the bulky covered stent cannot be implanted in the side branch, covering the main branch may be ineffective in preventing tamponade, specifically because of the collateral, which in this scenario, is clearly not "protective." 3,4Finally, we have a serious concern about the use of a covered stent to treat hypertrophic obstructive cardiomyopathy.There is probably a 20% risk of stent site stenosis, which, in the setting of hypertrophy, might place the patient at high risk for severe and possibly life-threatening ischemia.As such, this type of therapy must be viewed with extreme caution unless scientific data validate this approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Endothelial Function and Dysfunction: Testing and Clinical Relevance
Deanfield, J. E., Halcox, J. P., & Rabelink, T. J. (2007) · Circulation · doi:10.1161/circulationaha.106.652859 · Cited by 2,710
Biomarkers of Cardiovascular Disease: Molecular Basis and Practical Considerations
Vasan, R. S. (2006) · Circulation · doi:10.1161/circulationaha.104.482570 · Cited by 1,212
A systematic review and meta‐analyses on C‐reactive protein in relation to periodontitis
Paraskevas, S., Huizinga, J. D., & Loos, B. G. (2008) · Journal of Clinical Periodontology · doi:10.1111/j.1600-051x.2007.01173.x · Cited by 757
Endothelial and Antithrombotic Actions of HDL
Mineo, C., Deguchi, H., Griffin, J. H., & Shaul, P. W. (2006) · Circulation Research · doi:10.1161/01.res.0000225982.01988.93 · Cited by 655
Salpeter, S. R., Walsh, J. M. E., Ormiston, T. M., Greyber, E., Buckley, N. S., & Salpeter, E. E. (2006) · Diabetes, Obesity and Metabolism · doi:10.1111/j.1463-1326.2005.00545.x · Cited by 640
Metadata
- Authors
- Anzuini, A., & Uretsky, B. F.
- Venue
- Circulation
- Published
- 2004-01-20
- Volume
- 109
- Issue
- 2
- Pages
- e6-e6
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1975476120
- Cited by
- 82
- References
- 0
- FWCI
- 10.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Covered Stent Septal Ablation for Hypertrophic Obstruction Cardiomyopathy. https://app.cochat.ai/papers/10.1161/01.cir.0000111127.49988.79
- The paper
- Anzuini, A., & Uretsky, B. F. (2004). Covered Stent Septal Ablation for Hypertrophic Obstruction Cardiomyopathy. Circulation. https://doi.org/10.1161/01.cir.0000111127.49988.79
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.