Localized Hypersensitivity and Late Coronary Thrombosis Secondary to a Sirolimus-Eluting Stent: Should We Be Cautious?
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
Background— The US Food and Drug Administration recently issued a warning of subacute thrombosis and hypersensitivity reactions to sirolimus-eluting stents (Cypher). The cause and incidence of these events have not been determined. Methods and Results— We present findings of a 58-year-old man who died of late stent thrombosis 18 months after receiving 2 Cypher stents for unstable angina. Although angiographic and intravascular ultrasound results at 8 months demonstrated the absence of neointimal formation, vessel enlargement was present. An autopsy showed aneurysmal dilation of the stented arterial segments with a severe localized hypersensitivity reaction consisting predominantly of T lymphocytes and eosinophils. Conclusions— The known pharmacokinetic elution profile of Cypher stents and the presence of polymer fragments surrounded by giant cells and eosinophils suggest that a reaction to the polymer may have caused late stent thrombosis. Careful long-term follow-up of patients with vessel enlargement after Cypher stent placement is recommended.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moses, J. W., Leon, M. B., Popma, J. J., Fitzgerald, P. J., Holmes, D. R., O'Shaughnessy, C., Caputo, R. P., Kereiakes, D. J., Williams, D. O., Teirstein, P. S., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa035071 · Cited by 4,224
Morice, M.-C., Serruys, P. W., Sousa, J. E., Fajadet, J., Ban Hayashi, E., Perin, M., Colombo, A., Schuler, G., Barragan, P., Guagliumi, G., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa012843 · Cited by 4,033
Self-citationRequirement for IL-13 Independently of IL-4 in Experimental Asthma
Grünig, G., Warnock, M., Wakil, A. E., Venkayya, R., Brombacher, F., Rennick, D. M., Sheppard, D., Mohrs, M., Donaldson, D. D., Locksley, R. M., et al. (1998) · Science · doi:10.1126/science.282.5397.2261 · Cited by 1,849
Schofer, J., Schlüter, M., Gershlick, A. H., Wijns, W., Garcia, E., Schampaert, E., & Breithardt, G. (2003) · The Lancet · doi:10.1016/s0140-6736(03)14462-5 · Cited by 955
van der Giessen, W. J., Lincoff, A. M., Schwartz, R. S., van Beusekom, H. M. M., Serruys, P. W., Holmes, D. R., Ellis, S. G., & Topol, E. J. (1996) · Circulation · doi:10.1161/01.cir.94.7.1690 · Cited by 852
Sousa, J. E., Costa, M. A., Abizaid, A., Abizaid, A. S., Feres, F., Pinto, I. M. F., Seixas, A. C., Staico, R., Mattos, L. A., Sousa, A. G. M. R., et al. (2001) · Circulation · doi:10.1161/01.cir.103.2.192 · Cited by 793
Stent-Based Delivery of Sirolimus Reduces Neointimal Formation in a Porcine Coronary Model
Suzuki, T., Kopia, G., Hayashi, S.-I., Bailey, L. R., Llanos, G., Wilensky, R., Klugherz, B. D., Papandreou, G., Narayan, P., Leon, M. B., et al. (2001) · Circulation · doi:10.1161/hc3601.093987 · Cited by 708
Morphological Predictors of Restenosis After Coronary Stenting in Humans
Farb, A., Weber, D. K., Kolodgie, F. D., Burke, A. P., & Virmani, R. (2002) · Circulation · doi:10.1161/01.cir.0000019071.72887.bd · Cited by 593
Self-citationNickel and molybdenum contact allergies in patients with coronary in-stent restenosis
Köster, R., Vieluf, D., Kiehn, M., Sommerauer, M., Kähler, J., Baldus, S., Meinertz, T., & Hamm, C. W. (2000) · The Lancet · doi:10.1016/s0140-6736(00)03262-1 · Cited by 530
Pathological Mechanisms of Fatal Late Coronary Stent Thrombosis in Humans
Farb, A., Burke, A. P., Kolodgie, F. D., & Virmani, R. (2003) · Circulation · doi:10.1161/01.cir.0000091115.05480.b0 · Cited by 478
Self-citationNew Frontiers in Cardiology: Drug-Eluting Stents: Part I
Sousa, J. E., Serruys, P. W., & Costa, M. A. (2003) · Circulation · doi:10.1161/01.cir.0000069330.41022.90 · Cited by 349
Toxicity of methyl methacrylate in dentistry
Leggat, P. A., & Kedjarune, U. (2003) · International Dental Journal · doi:10.1111/j.1875-595x.2003.tb00736.x · Cited by 186
Deǧertekin, M., Serruys, P. W. J. C., Tanabe, K., Lee, C., Sousa, J. E., Colombo, A., Morice, M., Ligthart, J. M. R., & de Feyter, P. J. (2003) · Circulation · doi:10.1161/01.cir.0000103666.25660.77 · Cited by 154
New Frontiers in Cardiology: Drug-Eluting Stents: Part II
Sousa, J. E., Serruys, P. W. J. C., & Costa, M. A. (2003) · Circulation · doi:10.1161/01.cir.0000069331.67148.2f · Cited by 149
Revell, P. A., Braden, M., & Freeman, M. A. R. (1998) · Biomaterials · doi:10.1016/s0142-9612(97)00118-x · Cited by 91
Sirolimus-induced leukocytoclastic vasculitis
Hardinger, K. L., Cornelius, L. A., Trulock, E. P., & Brennan, D. C. (2002) · Transplantation · doi:10.1097/00007890-200209150-00025 · Cited by 50
Niemi, S. M., Fox, J. G., Brown, L. R., & Langer, R. (1985) · PubMed · Cited by 34
Charpentier, B., Groth, C. G., Bäckman, L., Morales, J. M., Calne, R. Y., Kreis, H., Lang, P., Touraine, J. L., Claesson, K., Campistol, J. M., et al. (2003) · Transplantation Proceedings · doi:10.1016/s0041-1345(03)00213-6 · Cited by 29
Cited by
Pathology of Drug-Eluting Stents in Humans
Joner, M., Finn, A. V., Farb, A., Mont, E. K., Kolodgie, F. D., Ladich, E., Kutys, R., Skorija, K., Gold, H. K., & Virmani, R. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.03.042 · Cited by 2,744
Self-citationDaemen, J., Wenaweser, P., Tsuchida, K., Abrecht, L., Vaina, S., Morger, C., Kukreja, N., Jüni, P., Sianos, G., Hellige, G., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60314-6 · Cited by 1,757
Safety and Efficacy of Sirolimus- and Paclitaxel-Eluting Coronary Stents
Stone, G. W., Moses, J. W., Ellis, S. G., Schofer, J., Dawkins, K. D., Morice, M.-C., Colombo, A., Schampaert, E., Grube, E., Kirtane, A. J., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa067193 · Cited by 1,631
ACC/AHA 2007 Guidelines on Perioperative Cardiovascular Evaluation and Care for Noncardiac Surgery
Fleisher, L. A., Beckman, J. A., Brown, K. A., Calkins, H., Chaikof, E. L., Fleischmann, K. E., Freeman, W. K., Froehlich, J. B., Kasper, E. K., Kersten, J. R., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.09.003 · Cited by 1,428
Late Clinical Events After Clopidogrel Discontinuation May Limit the Benefit of Drug-Eluting Stents
Pfisterer, M., Brunner-La Rocca, H. P., Buser, P. T., Rickenbacher, P., Hunziker, P., Mueller, C., Jeger, R., Bader, F., Osswald, S., & Kaiser, C. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.10.026 · Cited by 1,303
Metadata
- Authors
- Virmani, R., Guagliumi, G., Farb, A., Musumeci, G., Grieco, N., Motta, T., Mihalcsik, L., Tespili, M., Valsecchi, O., & Kolodgie, F. D.
- Venue
- Circulation
- Published
- 2004-02-17
- Volume
- 109
- Issue
- 6
- Pages
- 701-705
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1968528328
- Cited by
- 1,469
- References
- 18
- FWCI
- 99.35
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.