Pathological Mechanisms of Fatal Late Coronary Stent Thrombosis in Humans

Open access
Farb, Andrew, Burke, Allen P., Kolodgie, Frank D., Virmani, Renu·2003·Circulation

Abstract

Background— Coronary stent deployment is associated with a low incidence of acute thrombosis. However, late stent thrombosis (LST) has likely been underrecognized clinically, and pathological descriptions are lacking. Methods and Results— LST was defined as an acute thrombus within a stent that had been in place ≥30 days. Cases of LST were selected from a registry of human coronary stents submitted for analysis. Thirteen cases of LST (9 men, 4 women) were identified. The mean duration from implantation to thrombosis was 3.6±3.5 months (range, 1 to 11.9 months). The causes of death were sudden cardiac death (n=10), acute myocardial infarction (n=2), and heart failure (n=1). The pathological mechanisms of LST were as follows: (1) stenting across ostia of major arterial branches (5 cases); (2) exposure to radiation therapy (3 cases); (3) plaque disruption in the nonstented arterial segment within 2 mm of the stent margin (2 cases); (4) stenting of markedly necrotic, lipid-rich plaques with extensive plaque prolapse (2 cases); and (5) diffuse in-stent restenosis (1 case). Twelve cases demonstrated a failure to form a completely healed neointimal layer overlying stent struts. Underlying in-stent restenosis was present in only 4 (31%) of 13 cases. Conclusions— LST is a potentially fatal complication of coronary stenting. Stenting across branch ostia, disruption of adjacent vulnerable plaques, radiation therapy, and extensive plaque prolapse can precipitate LST. Impaired intimal healing (ie, the failure to form a complete neointimal layer over stent struts) extends the window during which stents are prone to thrombosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.0000091115.05480.b0

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Cited by

See all 478

Metadata

Authors
Farb, A., Burke, A. P., Kolodgie, F. D., & Virmani, R.
Venue
Circulation
Published
2003-10-07
Volume
108
Issue
14
Pages
1701-1706
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2164466909
Cited by
478
References
14
FWCI
19.43
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Pathological Mechanisms of Fatal Late Coronary Stent Thrombosis in Humans. https://app.cochat.ai/papers/10.1161/01.cir.0000091115.05480.b0
The paper
Farb, A., Burke, A. P., Kolodgie, F. D., & Virmani, R. (2003). Pathological Mechanisms of Fatal Late Coronary Stent Thrombosis in Humans. Circulation. https://doi.org/10.1161/01.cir.0000091115.05480.b0

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.