Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 717

The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.

Tight Glycemic Control in Diabetic Coronary Artery Bypass Graft Patients Improves Perioperative Outcomes and Decreases Recurrent Ischemic Events

Lazar, Harold L., Chipkin, Stuart R., Fitzgerald, Carmel A., Bao, Yusheng, Cabral, Howard, Apstein, Carl S.·2004·Circulation

Abstract

Background— This study sought to determine whether tight glycemic control with a modified glucose-insulin-potassium (GIK) solution in diabetic coronary artery bypass graft (CABG) patients would improve perioperative outcomes. Methods and Results— One hundred forty-one diabetic patients undergoing CABG were prospectively randomized to tight glycemic control (serum glucose, 125 to 200 mg/dL) with GIK or standard therapy (serum glucose <250 mg/dL) using intermittent subcutaneous insulin beginning before anesthesia and continuing for 12 hours after surgery. GIK patients had lower serum glucose levels (138±4 versus 260±6 mg/dL; P <0.0001), a lower incidence of atrial fibrillation (16.6% versus 42%; P =0.0017), and a shorter postoperative length of stay (6.5±0.1 versus 9.2±0.3 days; P =0.003). GIK patients also showed a survival advantage over the initial 2 years after surgery ( P =0.04) and decreased episodes of recurrent ischemia (5% versus 19%; P =0.01) and developed fewer recurrent wound infections (1% versus 10%, P =0.03). Conclusions— Tight glycemic control with GIK in diabetic CABG patients improves perioperative outcomes, enhances survival, and decreases the incidence of ischemic events and wound complications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.0000121747.71054.79

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 26 references

Cited by

See all 717

Metadata

Authors
Lazar, H. L., Chipkin, S. R., Fitzgerald, C. A., Bao, Y., Cabral, H., & Apstein, C. S.
Venue
Circulation
Published
2004-03-30
Volume
109
Issue
12
Pages
1497-1502
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2074745934
Cited by
717
References
26
FWCI
31.29
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Tight Glycemic Control in Diabetic Coronary Artery Bypass Graft Patients Improves Perioperative Outcomes and Decreases Recurrent Ischemic Events. https://app.cochat.ai/papers/10.1161/01.cir.0000121747.71054.79
The paper
Lazar, H. L., Chipkin, S. R., Fitzgerald, C. A., Bao, Y., Cabral, H., & Apstein, C. S. (2004). Tight Glycemic Control in Diabetic Coronary Artery Bypass Graft Patients Improves Perioperative Outcomes and Decreases Recurrent Ischemic Events. Circulation. https://doi.org/10.1161/01.cir.0000121747.71054.79

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.