Impact of Sirolimus-Eluting Stents on Outcome in Diabetic Patients: A SIRIUS (SIRolImUS-coated Bx Velocity balloon-expandable stent in the treatment of patients with de novo coronary artery lesions) Substudy
Abstract
Background— Randomized clinical trials have shown that a sirolimus-eluting stent significantly reduces restenosis after percutaneous coronary revascularization. Diabetic patients are known to have a higher risk of restenosis compared with nondiabetic patients. The purpose of this analysis was to determine the impact of sirolimus-eluting stents on outcomes of diabetic compared with nondiabetic patients. Methods and Results— The SIRIUS (SIRolImUS-coated Bx Velocity balloon-expandable stent in the treatment of patients with de novo coronary artery lesions) trial is a randomized, double-blind study that compared sirolimus-eluting and bare metal stent implantation in 1058 patients with de novo native coronary artery lesions. Diabetes mellitus was present in 279 (26%) patients (diabetes mellitus group, 131 patients received sirolimus-eluting stents and 148 patients received bare metal stents) and was absent in 778 patients (no–diabetes mellitus group, 402 patients received sirolimus-eluting stents and 376 patients received bare metal stents). At 270 days, target lesion revascularization was reduced in diabetic patients from 22.3% with bare metal stents to 6.9% with sirolimus-eluting stents ( P <0.001) and in nondiabetic patients from 14.1% to 2.99% ( P <0.001), respectively. Major adverse cardiac events were reduced in diabetic patients from 25% with bare metal stents to 9.2% with sirolimus-eluting stents ( P <0.001) and from 16.5% to 6.5% ( P <0.001) in nondiabetic patients, respectively. Conclusions— Implantation of sirolimus-eluting stents compared with bare metal stents in de novo coronary lesions reduces major adverse cardiac events in patients with and without diabetes mellitus. However, among patients receiving sirolimus-eluting stents, there remains a trend toward a higher frequency of repeat intervention in diabetic patients compared with nondiabetic patients, particularly in the insulin-requiring patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moses, J. W., Leon, M. B., Popma, J. J., Fitzgerald, P. J., Holmes, D. R., O'Shaughnessy, C., Caputo, R. P., Kereiakes, D. J., Williams, D. O., Teirstein, P. S., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa035071 · Cited by 4,224
Self-citationMorice, M.-C., Serruys, P. W., Sousa, J. E., Fajadet, J., Ban Hayashi, E., Perin, M., Colombo, A., Schuler, G., Barragan, P., Guagliumi, G., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa012843 · Cited by 4,033
Schofer, J., Schlüter, M., Gershlick, A. H., Wijns, W., Garcia, E., Schampaert, E., & Breithardt, G. (2003) · The Lancet · doi:10.1016/s0140-6736(03)14462-5 · Cited by 955
Freeman, D. J., Norrie, J., Sattar, N., Neely, R. D. G., Cobbe, S. M., Ford, I., Isles, C., Lorimer, A. R., Macfarlane, P. W., McKillop, J. H., et al. (2001) · Circulation · doi:10.1161/01.cir.103.3.357 · Cited by 844
Stein, B., Weintraub, W. S., Gebhart, S. S. P., Cohen-Bernstein, C. L., Grosswald, R., Liberman, H. A., Douglas, J. S., Morris, D. C., & King, S. B. (1995) · Circulation · doi:10.1161/01.cir.91.4.979 · Cited by 531
Diabetes mellitus and the clinical and angiographic outcome after coronary stent placement
Elezi, S., Kastrati, A., Pache, J., Wehinger, A., Hadamitzky, M., Dirschinger, J., Neumann, F.-J., & Schömig, A. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00467-7 · Cited by 495
Abizaid, A., Kornowski, R., Mintz, G. S., Hong, M. K., Abizaid, A. S., Mehran, R., Pichard, A. D., Kent, K. M., Satler, L. F., Wu, H., et al. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00286-1 · Cited by 458
Self-citationInfluence of diabetes mellitus on early and late outcome after coronary artery bypass grafting
Thourani, V. H., Weintraub, W. S., Stein, B., Gebhart, S. S. P., Craver, J. M., Jones, E. L., & Guyton, R. A. (1999) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(99)00143-5 · Cited by 413
Restenosis after Arterial Injury Caused by Coronary Stenting in Patients with Diabetes Mellitus
Carrozza, J. P., Kuntz, R. E., Fishman, R. F., & Baim, D. S. (1993) · Annals of Internal Medicine · doi:10.7326/0003-4819-118-5-199303010-00004 · Cited by 275
Self-citationNiles, N. W., McGrath, P. D., Malenka, D., Quinton, H., Wennberg, D., Shubrooks, S. J., Tryzelaar, J. F., Clough, R., Hearne, M. J., Hernandez, F., et al. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)01205-5 · Cited by 219
Cited by
Guidelines for Percutaneous Coronary Interventions
Silber, S., Albertsson, P., Avilés, F. F., Camici, P. G., Colombo, A., Hamm, C., Jørgensen, E., Marco, J., Nordrehaug, J.-E., Ruzyllo, W., et al. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi138 · Cited by 1,609
Coronary stents: A materials perspective
Mani, G., Feldman, M. D., Patel, D., & Agrawal, C. M. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.11.042 · Cited by 866
Increasing Cardiovascular Disease Burden Due to Diabetes Mellitus: The Framingham Heart Study
Fox, C. S., Coady, S., Sorlie, P. D., D’Agostino, R. B., Pencina, M. J., Vasan, R. S., Meigs, J. B., Levy, D., & Savage, P. J. (2007) · Circulation · doi:10.1161/circulationaha.106.658948 · Cited by 656
Jagur‐Grodzinski, J. (2006) · Polymers for Advanced Technologies · doi:10.1002/pat.729 · Cited by 394
Sabaté, M., Jiménez-Quevedo, P., Angiolillo, D. J., Gómez-Hospital, J. A., Alfonso, F., Hernández-Antolín, R., Goicolea, J., Bañuelos, C., Escaned, J., Moreno, R., et al. (2005) · Circulation · doi:10.1161/circulationaha.105.562421 · Cited by 368
Metadata
- Authors
- Moussa, I., Leon, M. B., Baim, D. S., O’Neill, W. W., Popma, J. J., Buchbinder, M., Midwall, J., Simonton, C. A., Keim, E., Wang, P., Kuntz, R. E., & Moses, J. W.
- Venue
- Circulation
- Published
- 2004-05-18
- Volume
- 109
- Issue
- 19
- Pages
- 2273-2278
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2133525542
- Cited by
- 397
- References
- 13
- FWCI
- 51.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Impact of Sirolimus-Eluting Stents on Outcome in Diabetic Patients: A SIRIUS (SIRolImUS-coated Bx Velocity balloon-expandable stent in the treatment of patients with de novo coronary artery lesions) Substudy. https://app.cochat.ai/papers/10.1161/01.cir.0000129767.45513.71
- The paper
- Moussa, I., Leon, M. B., Baim, D. S., O’Neill, W. W., Popma, J. J., Buchbinder, M., Midwall, J., Simonton, C. A., Keim, E., Wang, P., Kuntz, R. E., & Moses, J. W. (2004). Impact of Sirolimus-Eluting Stents on Outcome in Diabetic Patients: A SIRIUS (SIRolImUS-coated Bx Velocity balloon-expandable stent in the treatment of patients with de novo coronary artery lesions) Substudy. Circulation. https://doi.org/10.1161/01.cir.0000129767.45513.71
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.