Acute Improvement in Global and Regional Left Ventricular Systolic Function After Percutaneous Heart Valve Implantation in Patients With Symptomatic Aortic Stenosis

Open access
Bauer, Fabrice, Eltchaninoff, Hélène, Tron, Christophe, Lesault, Pierre-François, Agatiello, Carla, Nercolini, Deborah, Derumeaux, Geneviève, Cribier, Alain · 2004 · Circulation
Cited by 148

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background— The newly developed percutaneous heart valve (PHV) implantation technique decreases transaortic pressure gradient in patients with aortic stenosis. PHV replacement effects on left ventricular (LV) global and regional systolic function are currently unknown. Methods and Results— Eight patients with severe aortic stenosis had 2D echocardiography at baseline and 24 hours after PHV implantation to evaluate changes in LV volume and LV ejection fraction. Regional function, ie, both peak systolic anterior and posterior wall tissue velocity, as well as strain and strain rate imaging, were measured by tissue Doppler imaging from a short-axis view. At 24 hours, a significant reduction in transaortic mean pressure gradient (from 46±15 to 8±3 mm Hg; P <0.0001) was accompanied by an increase in aortic valve area (from 0.59±0.11 to 1.69±0.11 cm 2 ; P <0.0001). LV end-diastolic volume remained unchanged (102±36 to 101±12 mL; P =NS), whereas LV ejection fraction increased (48±18% to 57±12%; P <0.01). Improvement in posterior wall displacement (posterior wall tissue velocity increased from 2.2±0.5 to 4.4±1.0 cm/s −1 ; P =0.0003) and deformation (strain rate imaging increased from 1.0±0.3 to 1.9±0.7 s −1 , P =0.009, and strain increased from 11±5% to 17±9%; P =0.02) were observed. Conclusions— Immediately after PHV replacement, improvement of LV global and regional systolic function was evidenced by tissue Doppler imaging.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.0000134961.36773.d6

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 148

Metadata

Authors
Bauer, F., Eltchaninoff, H., Tron, C., Lesault, P.-F., Agatiello, C., Nercolini, D., Derumeaux, G., & Cribier, A.
Venue
Circulation
Published
2004-09-14
Volume
110
Issue
11
Pages
1473-1476
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2078663478
Cited by
148
References
1
FWCI
5.99
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Acute Improvement in Global and Regional Left Ventricular Systolic Function After Percutaneous Heart Valve Implantation in Patients With Symptomatic Aortic Stenosis. https://app.cochat.ai/papers/10.1161/01.cir.0000134961.36773.d6
The paper
Bauer, F., Eltchaninoff, H., Tron, C., Lesault, P.-F., Agatiello, C., Nercolini, D., Derumeaux, G., & Cribier, A. (2004). Acute Improvement in Global and Regional Left Ventricular Systolic Function After Percutaneous Heart Valve Implantation in Patients With Symptomatic Aortic Stenosis. Circulation. https://doi.org/10.1161/01.cir.0000134961.36773.d6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.