Relationship Between Activated Clotting Time and Ischemic or Hemorrhagic Complications: Analysis of 4 Recent Randomized Clinical Trials of Percutaneous Coronary Intervention
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Background— Unfractionated heparin (UFH) is the most widely used antithrombin during percutaneous coronary intervention (PCI). Despite significant pharmacological and mechanical advancements in PCI, uncertainty remains about the optimal activated clotting time (ACT) for prevention of ischemic or hemorrhagic complications. Methods and Results— We analyzed the outcome of all UFH-treated patients enrolled in 4 large, contemporary PCI trials with independent adjudication of ischemic and bleeding events. Of 9974 eligible patients, maximum ACT was available in 8369 (84%). The median ACT was 297 seconds (interquartile range 256 to 348 seconds). The incidence of death, myocardial infarction, or revascularization at 48 hours, by ACT quartile, was 6.2%, 6.8%, 6.0%, and 5.7%, respectively ( P =0.40 for trend). Covariate-adjusted rate of ischemic complications was not correlated with maximal procedural ACT (continuous value, P =0.29). Higher doses of UFH (>5000 U, or up to 90 U/kg) were independently associated with higher rates of events. The incidence of major or minor bleeding at 48 hours, by ACT quartile, was 2.9%, 3.5%, 3.8%, and 4.0%, respectively ( P =0.04 for trend). In a multivariable logistic model with a spline transformation for ACT, there was a linear increase in risk of bleeding as the ACT approached 365 seconds ( P =0.01), which leveled off beyond that value. Increasing UFH weight-indexed dose was independently associated with higher bleeding rates (OR 1.04 [1.02 to 1.07] for each 10 U/kg, P =0.001). Conclusions— In patients undergoing PCI with frequent stent and potent platelet inhibition use, ACT does not correlate with ischemic complications and has a modest association with bleeding complications, driven mainly by minor bleeding. Lower values do not appear to compromise efficacy while increasing safety.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Steinhubl, S. R., Berger, P. B., Mann III, J. T., Fry, E. T. A., DeLago, A., Wilmer, C., Topol, E. J., & for the CREDO Investigators (2002) · JAMA · doi:10.1001/jama.288.19.2411 · Cited by 3,078
Self-citation(1994) · New England Journal of Medicine · doi:10.1056/nejm199404073301402 · Cited by 2,589
(1997) · New England Journal of Medicine · doi:10.1056/nejm199706123362401 · Cited by 1,883
Lincoff, A. M., Bittl, J. A., Harrington, R. A., Feit, F., Kleiman, N. S., Jackman, J. D., Sarembock, I. J., Cohen, D. J., Spriggs, D., Ebrahimi, R., et al. (2003) · JAMA · doi:10.1001/jama.289.7.853 · Cited by 1,162
Self-citationTopol, E. J., Moliterno, D. J., Herrmann, H. C., Powers, E. R., Grines, C. L., Cohen, D. J., Cohen, E. A., Bertrand, M., Neumann, F.-J., Stone, G. W., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejm200106213442502 · Cited by 677
Self-citationLICHTMAN, M., SPIVAK, J., BOXER, L., SHATTIL, S., & HENDERSON, E. (2000) · Hematology · doi:10.1016/b978-012448510-5/50164-3 · Cited by 605
Landefeld, C. S., Cook, E. F., Flatley, M., Weisberg, M., & Goldman, L. (1987) · The American Journal of Medicine · doi:10.1016/0002-9343(87)90004-0 · Cited by 264
Lincoff, A. M., Bittl, J. A., Kleiman, N. S., Sarembock, I. J., Jackman, J. D., Mehta, S., Tannenbaum, M. A., Niederman, A. L., Bachinsky, W. B., Tift-Mann, J., et al. (2004) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2004.01.033 · Cited by 215
Self-citationMoliterno, D. J., Califf, R. M., Aguirre, F. V., Anderson, K. M., Sigmon, K. N., Weisman, H. F., Topol, E. J., & The EPIC Investigators (1995) · The American Journal of Cardiology · doi:10.1016/s0002-9149(99)80616-x · Cited by 142
Self-citationChew, D. P., Bhatt, D. L., Robbins, M. A., Mukherjee, D., Roffi, M., Schneider, J. P., Topol, E. J., & Ellis, S. G. (2001) · The American Journal of Cardiology · doi:10.1016/s0002-9149(01)01813-6 · Cited by 135
Self-citation
Cited by
Roffi, M., Patrono, C., Collet, J.-P., Mueller, C., Valgimigli, M., Andreotti, F., Bax, J. J., Borger, M. A., Brotons, C., Chew, D. P., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehv320 · Cited by 8,261
Writing Committee Members, Levine, G. N., Bates, E. R., Blankenship, J. C., Bailey, S. R., Bittl, J. A., Cercek, B., Chambers, C. E., Ellis, S. G., Guyton, R. A., et al. (2011) · Circulation · doi:10.1161/cir.0b013e31823ba622 · Cited by 3,289
WRITING COMMITTEE MEMBERS, Smith, S. C., Feldman, T. E., Hirshfeld, J. W., Jacobs, A. K., Kern, M. J., King, S. B., Morrison, D. A., O’Neill, W. W., Schaff, H. V., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.170815 · Cited by 2,218
2011 ACCF/AHA/SCAI Guideline for Percutaneous Coronary Intervention
Levine, G. N., Bates, E. R., Blankenship, J. C., Bailey, S. R., Bittl, J. A., Cercek, B., Chambers, C. E., Ellis, S. G., Guyton, R. A., Hollenberg, S. M., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.08.007 · Cited by 2,164
2021 ACC/AHA/SCAI Guideline for Coronary Artery Revascularization
Lawton, J. S., Tamis-Holland, J. E., Bangalore, S., Bates, E. R., Beckie, T. M., Bischoff, J. M., Bittl, J. A., Cohen, M. G., DiMaio, J. M., Don, C. W., et al. (2022) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2021.09.006 · Cited by 1,558
Lawton, J. S., Tamis-Holland, J. E., Bangalore, S., Bates, E. R., Beckie, T. M., Bischoff, J. M., Bittl, J. A., Cohen, M. G., DiMaio, J. M., Don, C. W., et al. (2022) · Circulation · doi:10.1161/cir.0000000000001038 · Cited by 829
ACC/AHA/SCAI 2005 Guideline Update for Percutaneous Coronary Intervention
Smith, S. C., Feldman, T. E., Hirshfeld, J. W., Jacobs, A. K., Kern, M. J., King, S. B., Morrison, D. A., O’Neill, W. W., Schaff, H. V., Whitlow, P. L., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.12.001 · Cited by 532
The Transradial Approach to Percutaneous Coronary Intervention
Rao, S. V., Cohen, M. G., Kandzari, D. E., Bertrand, O. F., & Gilchrist, I. C. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.01.039 · Cited by 343
Kumbhani, D. J., Cannon, C. P., Beavers, C. J., Bhatt, D. L., Cuker, A., Gluckman, T. J., Marine, J. E., Mehran, R., Messe, S. R., Patel, N. S., et al. (2021) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.09.011 · Cited by 308
2020 Clinical practice guidelines for Acute ST-segment elevation myocardial infarction
Russian Society of Cardiology, (. (2020) · Russian Journal of Cardiology · doi:10.15829/1560-4071-2020-4103 · Cited by 244
Nikolsky, E., Mehran, R., Dangas, G., Fahy, M., Na, Y., Pocock, S. J., Lincoff, A. M., & Stone, G. W. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm194 · Cited by 242
“In a prior pooled analysis from four large, contemporary PCI trials, lower weight was inversely correlated with bleeding, and greater weight-adjusted doses of unfractionated heparin were independently associated with higher bleeding rates.(15) Excess vascular complications may explain the association between thin body…”
ResultSelf-citationValgimigli, M., Campo, G., de Cesare, N., Meliga, E., Vranckx, P., Furgieri, A., Angiolillo, D. J., Sabatè, M., Hamon, M., Repetto, A., et al. (2009) · Circulation · doi:10.1161/circulationaha.108.833236 · Cited by 226
Silvain, J., Beygui, F., Barthelemy, O., Pollack, C., Cohen, M., Zeymer, U., Huber, K., Goldstein, P., Cayla, G., Collet, J.-P., et al. (2012) · BMJ · doi:10.1136/bmj.e553 · Cited by 225
Bates, S. M., & Weitz, J. I. (2005) · Circulation · doi:10.1161/circulationaha.104.478222 · Cited by 197
The FUTURA/OASIS-8 Trial Group, Steg, P. G., Jolly, S. S., Mehta, S. R., Afzal, R., Xavier, D., Rupprecht, H.-J., Lopez-Sendon, J. L., Budaj, A., Diaz, R., et al. (2010) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.2010.1320 · Cited by 191
Metadata
- Authors
- Brener, S. J., Moliterno, D. J., Lincoff, A. M., Steinhubl, S. R., Wolski, K. E., & Topol, E. J.
- Venue
- Circulation
- Published
- 2004-08-24
- Volume
- 110
- Issue
- 8
- Pages
- 994-998
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2109609988
- Cited by
- 181
- References
- 10
- FWCI
- 7.23
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.