Technique and Results of Linear Ablation at the Mitral Isthmus
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Background— This prospective clinical study evaluates the feasibility and efficacy of combined linear mitral isthmus ablation and pulmonary vein (PV) isolation in patients with paroxysmal atrial fibrillation (AF). Methods and Results— One hundred consecutive patients (13 women; age 55±10 years) with drug-refractory, symptomatic paroxysmal AF underwent PV isolation and linear ablation of the cavotricuspid isthmus and the mitral isthmus (lateral mitral annulus to the left inferior PV). They were compared with 100 consecutive patients (14 women; age, 52±10 years) undergoing PV isolation and cavotricuspid ablation without mitral isthmus ablation. Bidirectional mitral isthmus block was confirmed by demonstrating (1) a parallel corridor of double potentials during coronary sinus (CS) pacing, (2) an activation detour by pacing either side of the line, and (3) differential pacing techniques. Isolation of all PVs and cavotricuspid isthmus ablation were performed successfully in all. Mitral isthmus block was achieved in 92 patients after 20±10 minutes of endocardial radiofrequency application and an additional 5±4 minutes of epicardial radiofrequency application from within the CS in 68, resulting in a conduction delay of 151±26 ms during CS pacing. Thirty-two patients with mitral isthmus ablation compared with 49 without had recurrent atrial arrhythmia ( P =0.02) requiring further ablation. At 1 year after the last procedure, 87 patients with mitral isthmus ablation and 69 without ( P =0.002) were arrhythmia free without antiarrhythmic drugs, mitral isthmus ablation being the only factor associated with long-term success (RR for AF recurrence, 0.2; CI, 0.1 to 0.4; P <0.001). Conclusions— Catheter ablation of the mitral isthmus results consistently in demonstrable conduction block and is associated with a high cure rate for paroxysmal AF.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spontaneous Initiation of Atrial Fibrillation by Ectopic Beats Originating in the Pulmonary Veins
Haïssaguerre, M., Jaïs, P., Shah, D. C., Takahashi, A., Hocini, M., Quiniou, G., Garrigue, S., Le Mouroux, A., Le Métayer, P., & Clémenty, J. (1998) · New England Journal of Medicine · doi:10.1056/nejm199809033391003 · Cited by 7,975
Self-citationPulmonary Vein Isolation for Paroxysmal and Persistent Atrial Fibrillation
Oral, H., Knight, B. P., Tada, H., Özaydın, M., Chugh, A., Hassan, S., Scharf, C., Lai, S. W. K., Greenstein, R., Pelosi, F., et al. (2002) · Circulation · doi:10.1161/hc0902.104712 · Cited by 1,112
Haïssaguerre, M., Jaïs, P., Shah, D. C., Garrigue, S., Takahashi, A., Lavergne, T., Hocini, M., Peng, J. T., Roudaut, R., & Clémenty, J. (2000) · Circulation · doi:10.1161/01.cir.101.12.1409 · Cited by 922
Self-citationPappone, C., Oreto, G., Rosanio, S., Vicedomini, G., Tocchi, M., Gugliotta, F., Salvati, A., Dicandia, C., Calabrò, M. P., Mazzone, P., et al. (2001) · Circulation · doi:10.1161/hc4601.098517 · Cited by 863
Anatomy of the Left Atrium: Implications for Radiofrequency Ablation of Atrial Fibrillation
YEN HO, S., SANCHEZ‐QUINTANA, D., CABRERA, J. A., & ANDERSON, R. H. (1999) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1999.tb00211.x · Cited by 691
Circular mapping and ablation of thepulmonary vein for treatment of atrial fibrillation
Marrouche, N. F., Dresing, T., Cole, C., Bash, D., Saad, E., Balaban, K., Pavia, S. V., Schweikert, R., Saliba, W., Abdul-Karim, A., et al. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01972-1 · Cited by 399
Mapping and ablation of left atrial flutters
Jaïs, P., Shah, D. C., Haïssaguerre, M., Hocini, M., Peng, J. T., Takahashi, A., Garrigue, S., Le Métayer, P., & Clémenty, J. (2000) · Circulation · doi:10.1161/01.cir.101.25.2928 · Cited by 380
Self-citationCharacterization of Left Atrial Activation in the Intact Human Heart
Markides, V., Schilling, R. J., Yen Ho, S., Chow, A. W. C., Davies, D. W., & Peters, N. S. (2003) · Circulation · doi:10.1161/01.cir.0000048140.31785.02 · Cited by 284
Differential pacing for distinguishing block from persistent conduction through an ablation line
Shah, D., Haïssaguerre, M., Takahashi, A., Jaïs, P., Hocini, M., & Clémenty, J. (2000) · Circulation · doi:10.1161/01.cir.102.13.1517 · Cited by 242
Self-citationErnst, S., Schlüter, M., Ouyang, F., Khanedani, A., Cappato, R., Hebe, J., Volkmer, M., Antz, M., & Kuck, K.-H. (1999) · Circulation · doi:10.1161/01.cir.100.20.2085 · Cited by 205
Efficacy and safety of septal and left-atrial linear ablation for atrial fibrillation
Jaı̈s, P., Shah, D. C., Haı̈ssaguerre, M., Takahashi, A., Lavergne, T., Hocini, M., Garrigue, S., Barold, S. S., Le Métayer, P., & Clémenty, J. (1999) · The American Journal of Cardiology · doi:10.1016/s0002-9149(99)00714-6 · Cited by 173
Self-citationYamane, T., Jaı̈s, P., Shah, D. C., Hocini, M., Peng, J. T., Deisenhofer, I., Clémenty, J., & Haı̈ssaguerre, M. (2000) · Circulation · doi:10.1161/01.cir.102.21.2565 · Cited by 85
Self-citation
Cited by
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Self-citationApproaches to catheter ablation for persistent atrial fibrillation
Verma, A., Jiang, C.-Y., Betts, T. R., Chen, J., Deisenhofer, I., Mantovan, R., Macle, L., Morillo, C. A., Haverkamp, W., Weerasooriya, R., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1408288 · Cited by 2,339
Self-citationCalkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.04.005 · Cited by 1,701
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-012-9672-7 · Cited by 1,675
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.016 · Cited by 1,456
Metadata
- Authors
- Jaïs, P., Hocini, M., Hsu, L.-F., Sanders, P., Scavee, C., Weerasooriya, R., Macle, L., Raybaud, F., Garrigue, S., Shah, D. C., Le Metayer, P., Clémenty, J., & Haïssaguerre, M.
- Venue
- Circulation
- Published
- 2004-11-09
- Volume
- 110
- Issue
- 19
- Pages
- 2996-3002
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2117470639
- Cited by
- 751
- References
- 12
- FWCI
- 25.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.