Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 207

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Impaired Flow-Mediated Dilation and Risk of Restenosis in Patients Undergoing Coronary Stent Implantation

Open access
Patti, Giuseppe, Pasceri, Vincenzo, Melfi, Rosetta, Goffredo, Costanza, Chello, Massimo, D’Ambrosio, Andrea, Montesanti, Rosamaria, Di Sciascio, Germano · 2005 · Circulation

Abstract

Background— Impaired endothelial function is a key event in the atherosclerosis process and predicts future cardiovascular events in subjects with and without coronary artery disease (CAD). We performed the first prospective study evaluating whether early measurement of brachial artery endothelium-dependent dilation (flow-mediated dilation [FMD]) after coronary stenting could predict occurrence of in-stent-restenosis. Methods and Results— The study population included 136 patients with single-vessel CAD undergoing percutaneous coronary intervention (PCI) with stenting and at least 6 months of follow-up. All patients underwent ultrasound detection of brachial artery reactivity 30 days after PCI; FMD was investigated before and after 5 minutes of occlusion of the brachial artery, and nitroglycerin-mediated dilation was investigated before and after administration of sublingual nitrates. Clinical in-stent restenosis was demonstrated in 20 patients (15%), whereas 116 patients (85%) remained free of signs or symptoms of recurrent ischemia. FMD was significantly impaired in patients with restenosis versus those without restenosis (percent diameter variation 4.6±5.8% versus 9.5±6.6%, P =0.002); moreover, 4% of patients with FMD ≥7% (median value) developed in-stent restenosis versus 28% of those with FMD <7% ( P =0.0001). On multivariate analysis, FMD was the strongest predictor of restenosis (OR 4.5, 95% CI 2.4 to 12.0); conversely, nitroglycerin-mediated dilation did not independently predict the risk of restenosis (OR 2.4, 95% CI 0.8 to 6.3). Conclusions— This is the first prospective study indicating that impaired FMD independently predicts occurrence of in-stent restenosis in patients undergoing PCI. Early evaluation of endothelial function after stenting may represent a useful screening tool to stratify patients according to future risk of restenosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.0000151308.06673.d2

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 207

Metadata

Authors
Patti, G., Pasceri, V., Melfi, R., Goffredo, C., Chello, M., D’Ambrosio, A., Montesanti, R., & Di Sciascio, G.
Venue
Circulation
Published
2005-01-04
Volume
111
Issue
1
Pages
70-75
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1977889061
Cited by
207
References
3
FWCI
12.06
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Impaired Flow-Mediated Dilation and Risk of Restenosis in Patients Undergoing Coronary Stent Implantation. https://app.cochat.ai/papers/10.1161/01.cir.0000151308.06673.d2
The paper
Patti, G., Pasceri, V., Melfi, R., Goffredo, C., Chello, M., D’Ambrosio, A., Montesanti, R., & Di Sciascio, G. (2005). Impaired Flow-Mediated Dilation and Risk of Restenosis in Patients Undergoing Coronary Stent Implantation. Circulation. https://doi.org/10.1161/01.cir.0000151308.06673.d2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.