CoChat

Left Ventricular Systolic Performance, Function, and Contractility in Patients With Diastolic Heart Failure

Baicu, Catalin F., Zile, Michael R., Aurigemma, Gerard P., Gaasch, William H. · 2005 · Circulation
Cited by 291

The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.

Abstract

Background— Patients with diastolic heart failure (DHF) have significant abnormalities in left ventricular (LV) diastolic function, including slow and delayed relaxation and increased chamber stiffness. Whether and to what extent these abnormalities in diastolic function occur in association with abnormalities in LV systolic performance, function, and contractility has not been investigated thoroughly. Methods and Results— The systolic properties of the LV were examined in 75 patients with heart failure and a normal ejection fraction (ie, DHF) and 75 normal control subjects with no evidence of cardiovascular disease. LV systolic properties were assessed with echocardiographic and cardiac catheterization data. Stroke work (an index of LV systolic performance), preload recruitable stroke work and ejection fraction (indices of LV systolic function), systolic stress-shortening relationship, end-systolic pressure-volume relationship, and peak (+)dP/dt (indices of LV contractility) were examined. The systolic properties of the LV were normal in patients with DHF. Stroke work was 8.4±2.3 in DHF versus 8.8±2.5 kg · cm in controls ( P =0.26). Preload recruitable stroke work was 99±22 in DHF versus 109±18 g/cm 2 in controls ( P =0.13). The relationship between stroke work and end-diastolic volume was similar in DHF and controls. Peak (+) dP/dt was 1596±362 in DHF versus 1664±305 mm Hg/s in controls ( P =0.54). The end-systolic pressure-volume relationship was increased in DHF. The systolic stress versus endocardial fractional shortening relationship was similar in DHF and controls. Conclusions— Patients with DHF had normal LV systolic performance, function, and contractility. The pathophysiology of DHF does not appear to be related to significant abnormalities in these systolic properties of the LV.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.0000164273.57823.26

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 291

Metadata

Authors
Baicu, C. F., Zile, M. R., Aurigemma, G. P., & Gaasch, W. H.
Venue
Circulation
Published
2005-05-10
Volume
111
Issue
18
Pages
2306-2312
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2117460265
Cited by
291
References
32
FWCI
16.55
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.