The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
In Vivo Human Brachial Artery Elastic Mechanics: Effects of Smooth Muscle Relaxation
Abstract
Background —–The effects of smooth muscle relaxation on arterial wall mechanics are controversial. We used a new, in vivo, noninvasive technique to measure brachial artery wall mechanics under baseline conditions and following smooth muscle relaxation with nitroglycerin (NTG). Methods and Results —Eight healthy, normal subjects (6 male, 2 female; age 30±3.1 years) participated in the study. The nondominant brachial artery was imaged through a water-filled blood pressure cuff using an external ultrasound wall-tracking system at baseline and following 0.4 mg sublingual NTG. Simultaneous radial artery pressure waveforms were recorded by tonometry. Transmural pressure (TP) was reduced by increasing water pressure in the cuff. Brachial artery area, unstressed area, compliance, stress, strain, incremental elastic modulus (E inc ), and pulse wave velocity (PWV) were measured over a TP range from 0 to 100 mm Hg. Baseline area versus TP curves generated 30 minutes apart were not significantly different. NTG significantly shifted area versus TP ( P <0.0001) and compliance versus TP ( P <0.001) curves upward, whereas the E inc versus TP ( P <0.05) and PWV versus TP ( P <0.01) curves were shifted downward. NTG also significantly shifted stress versus strain ( P <0.01) and E inc versus strain ( P <0.01) curves to the right. Conclusions —We conclude that brachial artery elastic mechanics can be reproducibly measured over a wide range of TP and smooth muscle tone using a new noninvasive ultrasound technique. Smooth muscle relaxation with NTG increases isobaric compliance and decreases isobaric E inc and PWV in the human brachial artery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Mechanical Properties of Arteries in Vivo
PETERSON, L. H., JENSEN, R. E., & PARNELL, J. (1960) · Circulation Research · doi:10.1161/01.res.8.3.622 · Cited by 679
Cited by
Mechanisms, Pathophysiology, and Therapy of Arterial Stiffness
Zieman, S. J., Melenovsky, V., & Kass, D. A. (2005) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.0000160548.78317.29 · Cited by 1,854
Mechanical Factors in Arterial Aging
O’Rourke, M. F., & Hashimoto, J. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.12.050 · Cited by 1,250
The Central Role of Endothelial Dysfunction in Cardiorenal Syndrome
Zhang, J., Bottiglieri, T., & McCullough, P. A. (2017) · Cardiorenal Medicine · doi:10.1159/000452283 · Cited by 1,080
Noninvasive Assessment of Arterial Stiffness and Risk of Atherosclerotic Events
Oliver, J. J., & Webb, D. J. (2003) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.0000060460.52916.d6 · Cited by 823
Brutsaert, D. L. (2003) · Physiological Reviews · doi:10.1152/physrev.00017.2002 · Cited by 697
Urbina, E. M., Williams, R. V., Alpert, B. S., Collins, R. T., Daniels, S. R., Hayman, L., Jacobson, M., Mahoney, L., Mietus-Snyder, M., Rocchini, A., et al. (2009) · Hypertension · doi:10.1161/hypertensionaha.109.192639 · Cited by 641
Clinical applications of arterial stiffness, Task Force III: recommendations for user procedures
Van Bortel, L. M., Duprez, D., Starmans-Kool, M. J., Safar, M. E., Giannattasio, C., Cockcroft, J., Kaiser, D. R., & Thuillez, C. (2002) · American Journal of Hypertension · doi:10.1016/s0895-7061(01)02326-3 · Cited by 630
Self-citationNitric Oxide Regulates Local Arterial Distensibility In Vivo
Wilkinson, I. B., Qasem, A., McEniery, C. M., Webb, D. J., Avolio, A. P., & Cockcroft, J. R. (2002) · Circulation · doi:10.1161/hc0202.101970 · Cited by 502
Endothelium-Derived Nitric Oxide Regulates Arterial Elasticity in Human Arteries In Vivo
Kinlay, S., Creager, M. A., Fukumoto, M., Hikita, H., Fang, J. C., Selwyn, A. P., & Ganz, P. (2001) · Hypertension · doi:10.1161/hy1101.095329 · Cited by 385
Kaiser, D. R., Billups, K., Mason, C., Wetterling, R., Lundberg, J. L., & Bank, A. J. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.07.042 · Cited by 362
Self-citationMethods and devices for measuring arterial compliance in humans
Pannier, B. M., Avolio, A. P., Hoeks, A., Mancia, G., & Takazawa, K. (2002) · American Journal of Hypertension · doi:10.1016/s0895-7061(02)02962-x · Cited by 343
Surrogate Markers for Cardiovascular Disease: Functional Markers
Cohn, J. N., Quyyumi, A. A., Hollenberg, N. K., & Jamerson, K. A. (2004) · Circulation · doi:10.1161/01.cir.0000133442.99186.39 · Cited by 284
Arterial stiffness or endothelial dysfunction as a surrogate marker of vascular risk
Anderson, T. J. (2006) · Canadian Journal of Cardiology · doi:10.1016/s0828-282x(06)70990-4 · Cited by 178
Metadata
- Authors
- Bank, A. J., Kaiser, D. R., Rajala, S., & Cheng, A.
- Venue
- Circulation
- Published
- 1999-07-06
- Volume
- 100
- Issue
- 1
- Pages
- 41-47
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2114098249
- Cited by
- 159
- References
- 2
- FWCI
- 2.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.