Initiation of Atrial Fibrillation by Ectopic Beats Originating From the Pulmonary Veins: Electrophysiological Characteristics, Pharmacological Responses, and Effects of Radiofrequency Ablation
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
Background —Atrial fibrillation (AF) can be initiated by ectopic beats originating from the atrial or great venous tissues. This study investigated the anatomic characteristics and electrophysiological properties of pulmonary veins (PVs), as well as the possible mechanisms and response to drugs of ectopic foci, and assessed the effects of radiofrequency (RF) ablation on AF initiated by ectopic beats originating from PVs. Methods and Results —Seventy-nine patients with frequent episodes of paroxysmal AF and 10 control patients were included. Distal PVs showed the shortest effective refractory periods (ERPs), and right superior PVs showed a higher incidence of intra-PV conduction block than left superior PVs. Superior and left PVs had longer myocardial sleeves than inferior and right PVs, respectively. These electrophysiological characteristics were similar between AF and control patients. Propranolol, verapamil, and procainamide suppressed ectopic beats that originated from the PVs. Of 116 ectopic foci that initiated AF, 103 (88.8%) originated from PVs. A mean of 7±3 RF applications completely eliminated 110 ectopic foci (94.8%). During the 6±2-month follow-up period, 68 patients (86.1%) were free of AF without any antiarrhythmic drugs. Follow-up transesophageal echocardiogram showed 42.4% of ablated PVs had focal stenosis. One patient had mild exertional dyspnea after ablation, but it resolved 3 months later; 1 patient had onset of mild exertional dyspnea 5 months after ablation. Conclusions —Electrophysiological characteristics of PVs are different from those in the atria. Ectopic beats from PVs can initiate AF, and β-adrenergic receptor blocker, calcium channel blockers, and sodium channel blockers can suppress these ectopic beats. Careful mapping and elimination of these ectopic foci can cure paroxysmal AF.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spontaneous Initiation of Atrial Fibrillation by Ectopic Beats Originating in the Pulmonary Veins
Haïssaguerre, M., Jaïs, P., Shah, D. C., Takahashi, A., Hocini, M., Quiniou, G., Garrigue, S., Le Mouroux, A., Le Métayer, P., & Clémenty, J. (1998) · New England Journal of Medicine · doi:10.1056/nejm199809033391003 · Cited by 7,975
A Focal Source of Atrial Fibrillation Treated by Discrete Radiofrequency Ablation
Jai¨s, P., Hai¨ssaguerre, M., Shah, D. C., Chouairi, S., Gencel, L., Hocini, M., & Cle´menty, J. (1997) · Circulation · doi:10.1161/01.cir.95.3.572 · Cited by 1,117
High-density mapping of electrically induced atrial fibrillation in humans.
Konings, K. T., Kirchhof, C. J., Smeets, J. R., Wellens, H. J., Penn, O. C., & Allessie, M. A. (1994) · Circulation · doi:10.1161/01.cir.89.4.1665 · Cited by 962
Rensma, P. L., Allessie, M. A., Lammers, W. J., Bonke, F. I., & Schalij, M. J. (1988) · Circulation Research · doi:10.1161/01.res.62.2.395 · Cited by 640
Right and Left Atrial Radiofrequency Catheter Therapy of Paroxysmal Atrial Fibrillation
HAÍSSAGUERRE, M., JAÍS, P., SHAH, D. C., GENCEL, L., PRADEAU, V., GARRIGUES, S., CHOUAIRI, S., HOCINI, M., LE MÉTAYER, P., ROUDAUT, R., et al. (1996) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1996.tb00492.x · Cited by 577
Konings, K. T. S., Smeets, J. L. R. M., Penn, O. C., Wellens, H. J. J., & Allessie, M. A. (1997) · Circulation · doi:10.1161/01.cir.95.5.1231 · Cited by 452
Pulmonary Vein Stenosis After Catheter Ablation of Atrial Fibrillation
Robbins, I. M., Colvin, E. V., Doyle, T. P., Kemp, W. E., Loyd, J. E., McMahon, W. S., & Kay, G. N. (1998) · Circulation · doi:10.1161/01.cir.98.17.1769 · Cited by 443
The Junction Between the Left Atrium and the Pulmonary Veins: An Anatomic Study of Human Hearts
NATHAN, H., & Eliakim, M. (1966) · Circulation · doi:10.1161/01.cir.34.3.412 · Cited by 437
Chen, S. A., Chiang, C. E., Yang, C. J., Cheng, C. C., Wu, T. J., Wang, S. P., Chiang, B. N., & Chang, M. S. (1994) · Circulation · doi:10.1161/01.cir.90.3.1262 · Cited by 371
Self-citationElectrophysiologic studies in atrial fibrillation
Cosio, F. G., Palacios, J., Vidal, J. M., Cocina, E. G., Gómez-Sánchez, M. A., & Tamargo, L. (1983) · The American Journal of Cardiology · doi:10.1016/s0002-9149(83)80022-8 · Cited by 311
Studies on Auricular Tachycardia Caused by Aconitine Administration
Scherf, D. (1947) · Experimental Biology and Medicine · doi:10.3181/00379727-64-15754 · Cited by 278
Schuessler, R. B., Grayson, T. M., Bromberg, B. I., Cox, J. L., & Boineau, J. P. (1992) · Circulation Research · doi:10.1161/01.res.71.5.1254 · Cited by 265
Atrial conduction: Effects of extrastimuli with and without atrial dysrhythmias
Buxton, A. E., Waxman, H. L., Marchlinski, F. E., & Josephson, M. E. (1984) · The American Journal of Cardiology · doi:10.1016/s0002-9149(84)80203-9 · Cited by 226
Failure in the rate adaptation of the atrial refractory period: its relationship to vulnerability
Attuel, P., Childers, R., Cauchemez, B., Poveda, J., Mugica, J., & Coumel, P. (1982) · International Journal of Cardiology · doi:10.1016/0167-5273(82)90032-8 · Cited by 215
Cheung, D. W. (1981) · The Journal of Physiology · doi:10.1113/jphysiol.1981.sp013718 · Cited by 213
Conduction through a Narrow Isthmus in Isolated Canine Atrial Tissue: A Model of the W-P-W Syndrome
DE LA FUENTE, D., SASYNIUK, B., & MOE, G. K. (1971) · Circulation · doi:10.1161/01.cir.44.5.803 · Cited by 189
CHEN, S., TAI, C., YU, W., CHEN, Y., TSAI, C., HSIEH, M., CHEN, C., PRAKASH, V. S., DING, Y., & CHANG, M. (1999) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1999.tb00679.x · Cited by 179
Self-citationYu, W.-C., Chen, S.-A., Lee, S.-H., Tai, C.-T., Feng, A.-N., Kuo, B. I.-T., Ding, Y.-A., & Chang, M.-S. (1998) · Circulation · doi:10.1161/01.cir.97.23.2331 · Cited by 160
Self-citationAtrial excitability and conduction in patients with interatrial conduction defects
Simpson, R. J., Foster, J. R., & Gettes, L. S. (1982) · The American Journal of Cardiology · doi:10.1016/0002-9149(82)90471-4 · Cited by 136
Pulmonary vein as an ectopic focus in digitalis-induced arrhythmia
Cheung, D. W. (1981) · Nature · doi:10.1038/294582a0 · Cited by 121
Holm, M., Johansson, R., Brandt, J., Lührs, C., & Olsson, S. B. (1997) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a015233 · Cited by 104
HSIEH, M., Chen, S., TAI, C., TSAI, C., PRAKASH, V. S., YU, W., Liu, C. J., Ding, Y., & Chang, M.-S. (1999) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1999.tb00654.x · Cited by 103
Self-citationThe cardiac muscle in the pulmonary vein of the rat: A morphological and electrophysiological study
de Almeida, O. P., Böhm, G. M., Carvalho, M. D. P., & de Carvalho, A. P. (1975) · Journal of Morphology · doi:10.1002/jmor.1051450403 · Cited by 97
Tai, C.-T., Chen, S.-A., Chiang, C.-E., Lee, S.-H., Ueng, K.-C., Wen, Z.-C., Huang, J.-L., Chen, Y.-J., Yu, W.-C., Feng, A.-N., et al. (1997) · Circulation · doi:10.1161/01.cir.96.8.2601 · Cited by 82
Self-citationLee, S., Lin, F., Yu, W., Cheng, J.-J., Kuan, P., Hung, C., Chang, M.-S., & Chen, S. (1999) · Circulation · doi:10.1161/01.cir.99.9.1255 · Cited by 77
Self-citationAtrial refractoriness and spontaneous or induced atrial fibrillation.
Michelucci, A., Padeletti, L., & Fradella, G. A. (1982) · PubMed · Cited by 62
Li, H., HARE, J. W., Mughal, K., Krum, D. P., Biehl, M. L., DESHPANDE, S., Dhala, A. A., Blanck, Z., Sra, J. S., Jazayeri, M., et al. (1996) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(96)00068-x · Cited by 52
Cited by
Cappato, R., Calkins, H., Chen, S.-A., Davies, W., Iesaka, Y., Kalman, J., Kim, Y.-H., Klein, G., Natale, A., Packer, D., et al. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.859116 · Cited by 2,852
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.177292 · Cited by 2,805
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Self-citationNademanee, K., McKenzie, J., Kosar, E., Schwab, M., Sunsaneewitayakul, B., Vasavakul, T., Khunnawat, C., & Ngarmukos, T. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.12.054 · Cited by 2,002
Calkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.04.005 · Cited by 1,701
Self-citation
Metadata
- Authors
- Chen, S.-A., Hsieh, M.-H., Tai, C.-T., Tsai, C.-F., Prakash, V. S., Yu, W.-C., Hsu, T.-L., Ding, Y.-A., & Chang, M.-S.
- Venue
- Circulation
- Published
- 1999-11-02
- Volume
- 100
- Issue
- 18
- Pages
- 1879-1886
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2105450637
- Cited by
- 1,446
- References
- 27
- FWCI
- 36.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.