CoChat

Chronic N G -Nitro- l -Arginine Methyl Ester–Induced Hypertension: Novel Molecular Adaptation to Systolic Load in Absence of Hypertrophy

Open access
Bartunek, Jozef, Weinberg, Ellen O., Tajima, Minori, Rohrbach, Susanne, Katz, Sarah E., Douglas, Pamela S., Lorell, Beverly H. · 2000 · Circulation
Cited by 90

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background —Chronic N G -nitro- l -arginine methyl ester (L-NAME), which inhibits nitric oxide synthesis, causes hypertension and would therefore be expected to induce robust cardiac hypertrophy. However, L-NAME has negative metabolic effects on protein synthesis that suppress the increase in left ventricular (LV) mass in response to sustained pressure overload. In the present study, we used L-NAME–induced hypertension to test the hypothesis that adaptation to pressure overload occurs even when hypertrophy is suppressed. Methods and Results —Male rats received L-NAME (50 mg · kg −1 · d −1 ) or no drug for 6 weeks. Rats with L-NAME–induced hypertension had levels of systolic wall stress similar to those of rats with aortic stenosis (85±19 versus 92±16 kdyne/cm). Rats with aortic stenosis developed a nearly 2-fold increase in LV mass compared with controls. In contrast, in the L-NAME rats, no increase in LV mass (1.00±0.03 versus 1.04±0.04 g) or hypertrophy of isolated myocytes occurred (3586±129 versus 3756±135 μm 2 ) compared with controls. Nevertheless, chronic pressure overload was not accompanied by the development of heart failure. LV systolic performance was maintained by mechanisms of concentric remodeling (decrease of in vivo LV chamber dimension relative to wall thickness) and augmented myocardial calcium–dependent contractile reserve associated with preserved expression of α- and β-myosin heavy chain isoforms and sarcoplasmic reticulum Ca 2+ ATPase (SERCA-2). Conclusions —When the expected compensatory hypertrophic response is suppressed during L-NAME–induced hypertension, severe chronic pressure overload is associated with a successful adaptation to maintain systolic performance; this adaptation depends on both LV remodeling and enhanced contractility in response to calcium.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.101.4.423

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 90

Metadata

Authors
Bartunek, J., Weinberg, E. O., Tajima, M., Rohrbach, S., Katz, S. E., Douglas, P. S., & Lorell, B. H.
Venue
Circulation
Published
2000-02
Volume
101
Issue
4
Pages
423-429
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2061518671
Cited by
90
References
2
FWCI
6.82
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.