CoChat

Nitroglycerin Tolerance in Human Vessels: Evidence for Impaired Nitroglycerin Bioconversion

Open access
Sage, Peter R., de la Lande, Ivan S., Stafford, Irene, Bennett, Catherine L., Phillipov, George, Stubberfield, John, Horowitz, John D. · 2000 · Circulation
Cited by 143

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background—The basis for progressive attenuation of the effects of organic nitrates during long-term therapy (nitrate tolerance) remains controversial; proposed mechanisms include impaired nitrate bioconversion resulting in decreased release of nitric oxide (NO) from nitrates and/or increased NO clearance through a reaction with incrementally generated superoxide (O 2–). Methods and Results—Patients undergoing elective coronary artery bypass were randomized to receive 24 hours of intravenously infused nitroglycerin (NTG; nitrate group) or no nitrate therapy (control group). Discarded segments of the internal mammary artery and saphenous vein were used to examine (1) vascular responsiveness to NTG, sodium nitroprusside, and the calcium ionophore A23187; (2) bioconversion of NTG to 1,2- and 1,3-glyceryl dinitrate; and (3) the generation of O 2–. Responses to NTG were reduced 3- to 5-fold in vessels from the nitrate group compared with control vessels (P<0.01 for both types of segments), whereas responses to sodium nitroprusside and A23187 were unchanged. Tissue content of 1,2-glyceryl dinitrate was lower (P=0.012) in the saphenous veins from the nitrate group than in those from the control group. O 2–generation was greater (P<0.01) in internal mammary artery samples from the nitrate group than in those from the control group. However, incremental O 2–generation induced by an inhibitor of superoxide dismutase did not affect NTG responses. Conclusions—NTG tolerance in patients with coronary artery disease is nitrate-specific and is associated with evidence of impaired NTG bioconversion. Tolerance was associated with incremental O 2–generation, but short-term elevation of O 2–did not affect NTG responsiveness, suggesting increased NO clearance by O 2–has a minimal contribution to tolerance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.102.23.2810

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Sage, P. R., de la Lande, I. S., Stafford, I., Bennett, C. L., Phillipov, G., Stubberfield, J., & Horowitz, J. D.
Venue
Circulation
Published
2000-12-05
Volume
102
Issue
23
Pages
2810-2815
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1988717572
Cited by
143
References
2
FWCI
5.48
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.