Randomized Crossover Comparison of DDDR Versus VDD Pacing After Atrioventricular Junction Ablation for Prevention of Atrial Fibrillation
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background —Some clinical data suggest that atrial-based pacing prevents paroxysmal atrial fibrillation (AF). This study tested the hypothesis that DDDR pacing compared with VDD pacing prevents AF after atrioventricular (AV) junction ablation. Methods and Results —Patients were randomized to DDDR pacing (n=33) or to VDD pacing (n=34) after AV junction ablation and followed every 2 months for 6 months. Patients then crossed over to the alternate pacing mode and were followed for an additional 6 months. Primary analysis included the time to first recurrence of sustained AF (duration >5 minutes), total AF burden, and the development of permanent AF. The time to first episode of AF was similar in the DDDR group (0.37 days, 95% CI 0.1 to 1.3 days) and the VDD pacing group (0.5 days, 95% CI 0.2 to 1.7 days, P =NS). AF burden increased over time in both groups ( P <0.01). At the 6-month follow-up, AF burden was 6.93 h/d (95% CI 4.37 to 10.96 h/d) in the DDDR group and 6.30 h/d (95% CI 3.99 to 9.94 h/d) in the VDD group ( P =NS). Twelve (35%) patients in the DDDR group and 11 (32%) patients in the VDD group had permanent AF within 6 months of ablation. Within 1 year of follow-up, 43% of patients had permanent AF. Conclusions —DDDR pacing compared with VDD pacing does not prevent paroxysmal AF over the long term in patients in the absence of antiarrhythmic drug therapy after total AV junction ablation. Many patients have permanent AF within the first year after ablation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Andersen, H. R., Nielsen, J. C., Thomsen, P. E. B., Thuesen, L., Mortensen, P. T., Vesterlund, T., & Pedersen, A. K. (1997) · The Lancet · doi:10.1016/s0140-6736(97)03425-9 · Cited by 841
Cited by
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.177292 · Cited by 2,805
Joglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001193 · Cited by 2,765
2023 ACC/AHA/ACCP/HRS Guideline for the Diagnosis and Management of Atrial Fibrillation
Joglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2024) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2023.08.017 · Cited by 933
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Kay, G. N., Le Huezey, J.-Y., Lowe, J. E., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.09.013 · Cited by 924
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Kay, G. N., Le Huezey, J.-Y., Lowe, J. E., et al. (2011) · Circulation · doi:10.1161/cir.0b013e318214876d · Cited by 859
Writing Committee Members, Fuster, V., Ryden, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., et al. (2006) · Europace · doi:10.1093/europace/eul097 · Cited by 667
ACC/AHA/ESC 2006 Guidelines for the Management of Patients With Atrial Fibrillation
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.07.018 · Cited by 467
Canadian Trial of Physiological Pacing: Effects of Physiological Pacing During Long-Term Follow-Up
Kerr, C. R., Connolly, S. J., Abdollah, H., Roberts, R. S., Gent, M., Yusuf, S., Gillis, A. M., Tang, A. S. L., Talajic, M., Klein, G. J., et al. (2004) · Circulation · doi:10.1161/01.cir.0000109490.72104.ee · Cited by 194
Self-citationSaksena, S., Prakash, A., Ziegler, P., Hummel, J. D., Friedman, P., Plumb, V. J., Wyse, D. G., Johnson, E., Fitts, S., & Mehra, R. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02068-5 · Cited by 171
Self-citationPrakash, A., Saksena, S., Krol, R. B., Filipecki, A., & Philip, G. (2002) · Journal of Interventional Cardiac Electrophysiology · doi:10.1023/a:1015319618049 · Cited by 21
Metadata
- Authors
- Gillis, A. M., Connolly, S. J., Lacombe, P., Philippon, F., Dubuc, M., Kerr, C. R., Yee, R., Rose, M. S., Newman, D., Kavanagh, K. M., Gardner, M. J., Kus, T., Wyse, D. G., & (PA) Study Investigators ;
- Venue
- Circulation
- Published
- 2000-08-15
- Volume
- 102
- Issue
- 7
- Pages
- 736-741
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2077956363
- Cited by
- 109
- References
- 1
- FWCI
- 9.64
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.