The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Tissue Engineering of Pulmonary Heart Valves on Allogenic Acellular Matrix Conduits : In Vivo Restoration of Valve Tissue
Abstract
BACKGROUND: Tissue engineering using in vitro-cultivated autologous vascular wall cells is a new approach to biological heart valve replacement. In the present study, we analyzed a new concept to process allogenic acellular matrix scaffolds of pulmonary heart valves after in vitro seeding with the use of autologous cells in a sheep model. METHODS AND RESULTS: Allogenic heart valve conduits were acellularized by a 48-hour trypsin/EDTA incubation to extract endothelial cells and myofibroblasts. The acellularization procedure resulted in an almost complete removal of cells. After that procedure, a static reseeding of the upper surface of the valve was performed sequentially with autologous myofibroblasts for 6 days and endothelial cells for 2 days, resulting in a patchy cellular restitution on the valve surface. The in vivo function was tested in a sheep model of orthotopic pulmonary valve conduit transplantation. Three of 4 unseeded control valves and 5 of 6 tissue-engineered valves showed normal function up to 3 months. Unseeded allogenic acellular control valves showed partial degeneration (2 of 4 valves) and no interstitial valve tissue reconstitution. Tissue-engineered valves showed complete histological restitution of valve tissue and confluent endothelial surface coverage in all cases. Immunohistological analysis revealed cellular reconstitution of endothelial cells (von Willebrand factor), myofibroblasts (alpha-actin), and matrix synthesis (procollagen I). There were histological signs of inflammatory reactions to subvalvar muscle leading to calcifications, but these were not found in valve and pulmonary artery tissue. CONCLUSIONS: The in vitro tissue-engineering approach using acellular matrix conduits leads to the in vivo reconstitution of viable heart valve tissue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Langer, R., & Vacanti, J. P. (1993) · Science · doi:10.1126/science.8493529 · Cited by 9,893
Functional Arteries Grown in Vitro
Niklason, L. E., Gao, J., Abbott, W. M., Hirschi, K. K., Houser, S., Marini, R., & Langer, R. (1999) · Science · doi:10.1126/science.284.5413.489 · Cited by 1,766
Gabbiani, G., Schmid, E., Winter, S., Chaponnier, C., de Ckhastonay, C., Vandekerckhove, J., Weber, K., & Franke, W. W. (1981) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.78.1.298 · Cited by 484
Tissue engineering heart valves: Valve leaflet replacement study in a lamb model
Shinoka, T., Breuer, C. K., Tanel, R. E., Zund, G., Miura, T., Ma, P. X., Langer, R., Vacanti, J. P., & Mayer, J. E. (1995) · The Annals of Thoracic Surgery · doi:10.1016/0003-4975(95)00733-4 · Cited by 449
Creation Of Viable Pulmonary Artery Autografts Through Tissue Engineering
Shinoka, T., Shum-Tim, D., Ma, P. X., Tanel, R. E., Isogai, N., Langer, R., Vacanti, J. P., & Mayer, J. E. (1998) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(98)70315-0 · Cited by 444
Bader, A., Schilling, T., Teebken, O. E., Brandes, G., Herden, T., Steinhoff, G., & Haverich, A. (1998) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/s1010-7940(98)00171-7 · Cited by 340
Self-citationCheresh, D. A., Berliner, S. A., Vicente, V., & Ruggeri, Z. M. (1989) · Cell · doi:10.1016/0092-8674(89)90946-x · Cited by 335
Martin, U., Kiessig, V., Blusch, J. H., Haverich, A., von der Helm, K., Herden, T., & Steinhoff, G. (1998) · The Lancet · doi:10.1016/s0140-6736(98)07144-x · Cited by 311
Self-citationGALIS, Z. S., MUSZYNSKI, M., SUKHOVA, G. K., SIMON‐MORRISSEY, E., & LIBBY, P. (1994) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1994.tb17348.x · Cited by 274
Tissue-engineered valved conduits in the pulmonary circulation
Stock, U. A., Nagashima, M., Khalil, P. N., Nollert, G. D., Herdena, T., Sperling, J. S., Moran, A., Lien, J., Martin, D. P., Schoen, F. J., et al. (2000) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(00)70008-0 · Cited by 251
Self-citation
Cited by
Polymeric Scaffolds in Tissue Engineering Application: A Review
Dhandayuthapani, B., Yoshida, Y., Maekawa, T., & Kumar, D. S. (2011) · International Journal of Polymer Science · doi:10.1155/2011/290602 · Cited by 1,773
Electrospun scaffolds for tissue engineering of vascular grafts
Hasan, A., Memic, A., Annabi, N., Hossain, M., Paul, A., Dokmeci, M. R., Dehghani, F., & Khademhosseini, A. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.08.022 · Cited by 742
Mikos, A. G., Herring, S. W., Ochareon, P., Elisseeff, J., Lu, H. H., Kandel, R., Schoen, F. J., Toner, M., Mooney, D., Atala, A., et al. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.3307 · Cited by 598
Alternatives to animal testing: a review
Doke, S. K., & Dhawale, S. C. (2015) · Saudi Pharmaceutical Journal · doi:10.1016/j.jsps.2013.11.002 · Cited by 564
Rieder, E., Kasimir, M.-T., Silberhumer, G., Seebacher, G., Wolner, E., Simon, P., & Weigel, G. (2004) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2003.06.017 · Cited by 430
Metadata
- Authors
- Steinhoff, G., Stock, U., Karim, N., Mertsching, H., Timke, A., Meliss, R. R., Pethig, K., Haverich, A., & Bader, A.
- Venue
- Circulation
- Published
- 2000-11-07
- Volume
- 102
- Issue
- Supplement 3
- Pages
- III-50-III-55
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2038425254
- Cited by
- 352
- References
- 15
- FWCI
- 14.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tissue Engineering of Pulmonary Heart Valves on Allogenic Acellular Matrix Conduits : In Vivo Restoration of Valve Tissue. https://app.cochat.ai/papers/10.1161/01.cir.102.suppl_3.iii-50
- The paper
- Steinhoff, G., Stock, U., Karim, N., Mertsching, H., Timke, A., Meliss, R. R., Pethig, K., Haverich, A., & Bader, A. (2000). Tissue Engineering of Pulmonary Heart Valves on Allogenic Acellular Matrix Conduits : In Vivo Restoration of Valve Tissue. Circulation. https://doi.org/10.1161/01.cir.102.suppl_3.iii-50
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.