The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Electrical Impedance Plethysmography: A Physical and Physiologic Approach to Peripheral Vascular Study
Open accessAbstract
The quantity of blood measured by electrical impedance plethysmography is defined by its resistive effect in parallel to the resistance of other tissue of the segment. By substitution of this parallel resistive value, together with data relative to the resistivity of blood and the length of the segment in the formula for the volume of an electrical conductor, we are able to derive the volume of the pulse in cubic centimeters. It follows that the volume displaced from the venous reservoir and the rate of refilling of the venous reservoir of an extremity may also be determined quantitatively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new sensitive portable plethysmograph
Burch, G. E. (1947) · American Heart Journal · doi:10.1016/0002-8703(47)90424-9 · Cited by 64
THERMAL GRADIENTS IN THE VASCULAR SYSTEM
Horvath, S. M., RUBIN, A. M., & Foltz, E. L. (1950) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1950.161.2.316 · Cited by 39
Cited by
Bioelectrical impedance analysis?part I: review of principles and methods
KYLE, U. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.06.004 · Cited by 3,200
Assessment of fat-free mass using bioelectrical impedance measurements of the human body
Lukaski, H., Johnson, P., Bolonchuk, W., & Lykken, G. (1985) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/41.4.810 · Cited by 1,896
Geddes, L. A., & Baker, L. E. (1967) · Medical & Biological Engineering · doi:10.1007/bf02474537 · Cited by 1,610
Toward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935
“One path is cylindrical and represents the pulsatile blood (ac impedance component), while the other path represents all other tissues including bone, fat, muscle, and nonpulsatile fluids (dc impedance component) [85], [86].”
BackgroundMethodEstimation of total body water by bioelectrical impedance analysis
Kushner, R., & Schoeller, D. (1986) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/44.3.417 · Cited by 772
Metadata
- Authors
- NYBOER, J., Kreider, M. M., & Hannapel, L.
- Venue
- Circulation
- Published
- 1950-12
- Volume
- 2
- Issue
- 6
- Pages
- 811-821
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2005002475
- Cited by
- 490
- References
- 2
- FWCI
- 2.48
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.