The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Disparities Between Aortic and Peripheral Pulse Pressures Induced by Upright Exercise and Vasomotor Changes in Man
Abstract
Blood pressures were recorded simultaneously from the aortic arch and radial artery using two manometric systems with identical static and dynamic sensitivities. Measurements were made in four normal young men at rest and upright exercise requiring 29, 49, 78, and 100% of maximal oxygen uptake. Average radial arterial pressure rose from 133/66 mm Hg at rest to 236/58 mm Hg at maximal exercise. At the same time, average aortic pressures were 112/68 and 154/70 mm Hg, respectively. From rest to maximal exercise, pulse pressures at central and peripheral sites increased by factors of 1.95 and 2.60, respectively. Inducing reactive hyperemia in the arm abolished peripheral amplification. This amplification also diminished with time during prolonged heavy exercise. Mean pressures were nearly identical at the two sites at any oxygen uptake; mean pressures rose from 87 to 104 mm Hg from mild to maximal exercise. We conclude that estimates of stress on aortic and cerebral vessel walls and central baroreceptors would be grossly overestimated by use of peripheral pulse pressures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximal Oxygen Intake as an Objective Measure of Cardio-Respiratory Performance
Taylor, H. L., Buskirk, E., & Henschel, A. (1955) · Journal of Applied Physiology · doi:10.1152/jappl.1955.8.1.73 · Cited by 1,342
KROEKER, E. J., & WOOD, E. H. (1955) · Circulation Research · doi:10.1161/01.res.3.6.623 · Cited by 423
THE CIRCULATIORY EFFECTS OF SUSTAINED VOLUNTARY MUSCLE CONTRACTION.
LIND, A. R., Taylor, S. H., Humphreys, P. W., Kennelly, B. M., & Donald, K. W. (1964) · PubMed · Cited by 414
Burton, A. C. (1939) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1939.127.3.437 · Cited by 333
Circulatory adaptation to arm and leg exercise in supine and sitting position.
Bevegård, S., Freyschuss, U., & Strandell, T. (1966) · Journal of Applied Physiology · doi:10.1152/jappl.1966.21.1.37 · Cited by 261
Splanchnic blood flow and metabolism in heat-stressed man.
Rowell, L. B., Brengelmann, G. L., Blackmon, J. R., Twiss, R. D., & Kusumi, F. (1968) · Journal of Applied Physiology · doi:10.1152/jappl.1968.24.4.475 · Cited by 208
Self-citationReaction in man of resistance and capacity vessels in forearm and hand to leg exercise.
Bevegård, B. S., & Shepherd, J. T. (1966) · Journal of Applied Physiology · doi:10.1152/jappl.1966.21.1.123 · Cited by 206
Central circulatory responses to work in dry heat before and after acclimatization
Rowell, L. B., Kraning, K. K., Kennedy, J. W., & Evans, T. O. (1967) · Journal of Applied Physiology · doi:10.1152/jappl.1967.22.3.509 · Cited by 111
Self-citation
Cited by
Laurent, S., Boutouyrie, P., Asmar, R., Gautier, I., Laloux, B., Guize, L., Ducimetiere, P., & Benetos, A. (2001) · Hypertension · doi:10.1161/01.hyp.37.5.1236 · Cited by 3,856
Franklin, S. S., Larson, M. G., Khan, S. A., Wong, N. D., Leip, E. P., Kannel, W. B., & Levy, D. (2001) · Circulation · doi:10.1161/01.cir.103.9.1245 · Cited by 1,390
Pauca, A. L., O’Rourke, M. F., & Kon, N. D. (2001) · Hypertension · doi:10.1161/hy1001.096106 · Cited by 1,179
KARAMANOGLU, M., O'ROURKE, M. F., AVOLIO, A. P., & KELLY, R. P. (1993) · European Heart Journal · doi:10.1093/eurheartj/14.2.160 · Cited by 873
Gobel, F. L., Norstrom, L. A., Nelson, R. R., Jorgensen, C. R., & Wang, Y. (1978) · Circulation · doi:10.1161/01.cir.57.3.549 · Cited by 866
Joyner, M. J., & Casey, D. P. (2015) · Physiological Reviews · doi:10.1152/physrev.00035.2013 · Cited by 833
Noninvasive Assessment of Arterial Stiffness and Risk of Atherosclerotic Events
Oliver, J. J., & Webb, D. J. (2003) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.0000060460.52916.d6 · Cited by 823
Vascular Adaptation to Exercise in Humans: Role of Hemodynamic Stimuli
Green, D. J., Hopman, M. T. E., Padilla, J., Laughlin, M. H., & Thijssen, D. H. J. (2017) · Physiological Reviews · doi:10.1152/physrev.00014.2016 · Cited by 821
Rossi, P., Andriesse, G. I., Oey, P. L., Wieneke, G. H., Roelofs, J. M. M., & Akkermans, L. M. A. (1998) · Journal of the Neurological Sciences · doi:10.1016/s0022-510x(98)00276-7 · Cited by 767
O'Rourke, M. F., Pauca, A., & Jiang, X. (2001) · British Journal of Clinical Pharmacology · doi:10.1046/j.0306-5251.2001.01400.x · Cited by 640
Hemodynamic Predictors of Myocardial Oxygen Consumption During Static and Dynamic Exercise
NELSON, R. R., GOBEL, F. L., JORGENSEN, C. R., WANG, K., WANG, Y., & TAYLOR, H. L. (1974) · Circulation · doi:10.1161/01.cir.50.6.1179 · Cited by 500
Non‐invasive pulsatile arterial pressure and stroke volume changes from the human finger
Bogert, L. W. J., & van Lieshout, J. J. (2005) · Experimental Physiology · doi:10.1113/expphysiol.2005.030262 · Cited by 413
Mechanical Principles in Arterial Disease
O’Rourke, M. (1995) · Hypertension · doi:10.1161/01.hyp.26.1.2 · Cited by 401
Kelly, R., & Fitchett, D. (1992) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(92)90198-v · Cited by 361
Heart rate dependency of pulse pressure amplification and arterial stiffness
Wilkinson, I. B., Mohammad, N. H., Tyrrell, S., Hall, I. R., Webb, D. J., Paul, V. E., Levy, T., & Cockcroft, J. R. (2002) · American Journal of Hypertension · doi:10.1016/s0895-7061(01)02252-x · Cited by 357
JOHNSON, J. M., ROWELL, L. B., NIEDERBERGER, M., & EISMAN, M. M. (1974) · Circulation Research · doi:10.1161/01.res.34.4.515 · Cited by 340
“Methods for the optimal electronic registration of aortic pulse pressure and aortic mean pressure from the same catheter and a Statham P23Gb transducer have been previously described (11).”
Self-citationVentricular Arterial Stiffening: Integrating the Pathophysiology
Kass, D. A. (2005) · Hypertension · doi:10.1161/01.hyp.0000168053.34306.d4 · Cited by 335
Avolio, A. P., Butlin, M., & Walsh, A. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/1/r01 · Cited by 310
Sharman, J. E., Lim, R., Qasem, A. M., Coombes, J. S., Burgess, M. I., Franco, J., Garrahy, P., Wilkinson, I. B., & Marwick, T. H. (2006) · Hypertension · doi:10.1161/01.hyp.0000223013.60612.72 · Cited by 308
Pressure Amplification Explains Why Pulse Pressure Is Unrelated to Risk in Young Subjects
Wilkinson, I. B., Franklin, S. S., Hall, I. R., Tyrrell, S., & Cockcroft, J. R. (2001) · Hypertension · doi:10.1161/hy1201.097723 · Cited by 273
Sexual Activity and the Postcoronary Patient
Hellerstein, H. K. (1970) · Archives of Internal Medicine · doi:10.1001/archinte.1970.00310060065006 · Cited by 256
Sharman, J. E., Avolio, A. P., Baulmann, J., Benetos, A., Blacher, J., Blizzard, C. L., Boutouyrie, P., Chen, C.-H., Chowienczyk, P., Cockcroft, J. R., et al. (2017) · European Heart Journal · doi:10.1093/eurheartj/ehw632 · Cited by 231
Genesis of the normal and abnormal arterial pulse
Vlachopoulos, C., & O'Rourke, M. (2000) · Current Problems in Cardiology · doi:10.1067/mcd.2000.104057 · Cited by 125
Hedman, K., Cauwenberghs, N., Christle, J. W., Kuznetsova, T., Haddad, F., & Myers, J. (2020) · European Journal of Preventive Cardiology · doi:10.1177/2047487319877268 · Cited by 89
The normal response to prolonged passive head up tilt testing
Petersen, M. E. V., Williams, T. R., Gordon, C., Chamberlain-Webber, R., & Sutton, R. (2000) · Heart · doi:10.1136/heart.84.5.509 · Cited by 85
Effect of Caffeine on Aortic Elastic Properties and Wave Reflection
Vlachopoulos, C., Hirata, K., & O'Rourke, M. F. (2003) · Journal of Hypertension · doi:10.1097/00004872-200303000-00022 · Cited by 79
Blood Pressure Behaviour During Physical Activity
Palatini, P. (1988) · Sports Medicine · doi:10.2165/00007256-198805060-00002 · Cited by 77
Armstrong, M. K., Schultz, M. G., Picone, D. S., Black, J. A., Dwyer, N., Roberts-Thomson, P., & Sharman, J. E. (2019) · Hypertension · doi:10.1161/hypertensionaha.119.12674 · Cited by 59
Metadata
- Authors
- ROWELL, L. B., BRENGELMANN, G. L., BLACKMON, J. R., BRUGE, R. A., & MURRAY, J. A.
- Venue
- Circulation
- Published
- 1968-06
- Volume
- 37
- Issue
- 6
- Pages
- 954-964
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2127334473
- Cited by
- 257
- References
- 8
- FWCI
- 6.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.