Direct Correlation of External Systolic Time Intervals with Internal Indices of Left Ventricular Function in Man
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Direct correlation of externally measured systolic time intervals with internally measured indices was obtained using catheter-tip micromanometers in six patients who had normal coronary arteriograms. Simultaneous recordings were made of central aorta and left ventricular pressure, maximum rate of rise in left ventricular pressure (dp/dt), external carotid pulse, external and internal sound, and electrocardiogram. Acute interventions were used to vary the indices by a variety of mechanisms including changes in contractility, preload, afterload, and heart rate. The initial values and the changes in these values produced by acute interventions are identical for left ventricular ejection time (LVET) whether measured externally (range 175 to 385 msec) or internally (range 169 to 392), r = 0.99. Although the absolute values differed for internally measured isovolumic contraction time (internal ICT), externally measured ICT, and preejection time (PEP), there was good linear correlation between the changes observed in these values following the interventions. Changes in PEP and internal ICT showed excellent linear correlation (r = 0.94) and were also alike in absolute value following the interventions. The interval from the Q wave of the electrocardiogram to rise in left ventricular pressure (electrical-mechanical delay) did not change significantly during these interventions. During a period of spontaneous isorhythmic dissociation there was close tracking between beat-to-beat changes in PEP and internal ICT and between externally and internally measured LVET. Following acute interventions PEP and left ventricular dp/dt changed inversely. Externally measured systolic time intervals have therefore been shown in man to correlate well with directly measured internal indices, both in steady-state conditions and during a series of acute interventions. This convenient and atraumatic method has been shown to be a valid and sensitive measure of myocardial performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bedside technics for the evaluation of ventricular function in man
Weissler, A. M., Harris, W. S., & Schoenfeld, C. D. (1969) · The American Journal of Cardiology · doi:10.1016/0002-9149(69)90012-5 · Cited by 599
Mason, D. T. (1969) · The American Journal of Cardiology · doi:10.1016/0002-9149(69)90005-8 · Cited by 459
GARRARD, C. L., WEISSLER, A. M., & DODGE, H. T. (1970) · Circulation · doi:10.1161/01.cir.42.3.455 · Cited by 450
Weissler, A. M., Peeler, R. G., & Roehll, W. H. (1961) · American Heart Journal · doi:10.1016/0002-8703(61)90403-3 · Cited by 439
The Pharmacological Basis of Therapeutics.
Gemmill, C. L. (1966) · Journal of Medicinal Chemistry · doi:10.1021/jm00324a062 · Cited by 436
STUDIES ON THE FIRST DERIVATIVE OF THE VENTRICULAR PRESSURE PULSE IN MAN
Gleason, W. L., & Braunwald, E. (1962) · Journal of Clinical Investigation · doi:10.1172/jci104469 · Cited by 409 · cited 1×
“The following mean values were calculated for each group of complexes: (1) R-R and P-R interval of the electrocardiogram; (2) external left ventricular ejection time, measured from the rapid upstroke to the nadir of the incisura of the external carotid pulse tracing, with only carotid tracings shown on the oscilloscop…”
MethodHemodynamic determinants of the maximal rate of rise of left ventricular pressure
Wallace, A. G., Skinner, N. S., & Mitchell, J. H. (1963) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1963.205.1.30 · Cited by 318
Harris, W. S., Schoenfeld, C. D., & Weissler, A. M. (1967) · Journal of Clinical Investigation · doi:10.1172/jci105661 · Cited by 266
Duration of the Phases of Left Ventricular Systole
WALLACE, A. G., MITCHELL, J. H., SKINNER, N. S., & SARNOFF, S. J. (1963) · Circulation Research · doi:10.1161/01.res.12.6.611 · Cited by 204
Lind, A. R., & McNicol, G. W. (1967) · The Journal of Physiology · doi:10.1113/jphysiol.1967.sp008319 · Cited by 196
Cited by
Methodological Guidelines for Impedance Cardiography
Sherwood(Chair), A., Allen, M. T., Fahrenberg, J., Kelsey, R. M., Lovallo, W. R., & van Doornen, L. J. P. (1990) · Psychophysiology · doi:10.1111/j.1469-8986.1990.tb02171.x · Cited by 1,169
AHMED, S. S., LEVINSON, G. E., SCHWARTZ, C. J., & ETTINGER, P. O. (1972) · Circulation · doi:10.1161/01.cir.46.3.559 · Cited by 241
Autonomic Mechanisms in Hemodynamic Responses to Isometric Exercise
Martin, C. E., Shaver, J. A., Leon, D. F., Thompson, M. E., Reddy, P. S., & Leonard, J. J. (1974) · Journal of Clinical Investigation · doi:10.1172/jci107731 · Cited by 227
Self-citationBorow, K. M., Neumann, A., & Wynne, J. (1982) · Circulation · doi:10.1161/01.cir.65.5.988 · Cited by 215
Di Rienzo, M., Vaini, E., Castiglioni, P., Merati, G., Meriggi, P., Parati, G., Faini, A., & Rizzo, F. (2013) · Autonomic Neuroscience · doi:10.1016/j.autneu.2013.04.005 · Cited by 163
Metadata
- Authors
- MARTIN, C. E., SHAVER, J. A., THOMPSON, M. E., REDDY, P. S., & LEONARD, J. J.
- Venue
- Circulation
- Published
- 1971-09
- Volume
- 44
- Issue
- 3
- Pages
- 419-431
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2094920763
- Cited by
- 192
- References
- 19
- FWCI
- 12.24
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Direct Correlation of External Systolic Time Intervals with Internal Indices of Left Ventricular Function in Man. https://app.cochat.ai/papers/10.1161/01.cir.44.3.419
- The paper
- MARTIN, C. E., SHAVER, J. A., THOMPSON, M. E., REDDY, P. S., & LEONARD, J. J. (1971). Direct Correlation of External Systolic Time Intervals with Internal Indices of Left Ventricular Function in Man. Circulation. https://doi.org/10.1161/01.cir.44.3.419
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.