Wearable seismocardiography: Towards a beat-by-beat assessment of cardiac mechanics in ambulant subjects
Abstract
Seismocardiogram (SCG) is the measure of the micro-vibrations produced by the heart contraction and blood ejection into the vascular tree. Over time, a large body of evidence has been collected on the ability of SCG to reflect cardiac mechanical events such as opening and closure of mitral and aortic valves, atrial filling and point of maximal aortic blood ejection. We recently developed a smart garment, named MagIC-SCG, that allows the monitoring of SCG, electrocardiogram (ECG) and respiration out of the laboratory setting in ambulant subjects. The present pilot study illustrates the results of two different experiments performed to obtain a first evaluation on whether a dynamical assessment of indexes of cardiac mechanics can be obtained from SCG recordings obtained by MagIC-SCG. In the first experiment, we evaluated the consistency of the estimates of two indexes of cardiac contractility, the pre-ejection period, PEP, and the left ventricular ejection time, LVET. This was done in the lab, by reproducing an experimental protocol well known in literature, so that our measures derived from SCG could have been compared with PEP and LVET reference values obtained by traditional techniques. Six healthy subjects worn MagIC-SCG while assuming two different postures (supine and standing); PEP was estimated as the time interval between the Q wave in ECG and the SCG wave corresponding to the opening of aortic valve; LVET was the time interval between the SCG waves corresponding to the opening and closure of the aortic valve. The shift from supine to standing posture produced a significant increase in PEP and PEP/LVET ratio, a reduction in LVET and a concomitant rise in the LF/HF ratio in the RR interval (RRI) power spectrum. These results are in line with data available in literature thus providing a first support to the validity of our estimates. In the second experiment, we evaluated in one subject the feasibility of the beat-by-beat assessment of LVET during spontaneous behavior. The subject was continuously monitored by the smart garment from 8 am to 8 pm during a workday. From the whole recording, three data segments were selected: while the subject was traveling to work (M1), during work in the office (O) and while traveling back home (M2). LVET was estimated on a beat-by-beat basis from SCG and the RRI influence was removed by regression analysis. The LVET series displayed marked beat-by-beat fluctuations at the respiratory frequency. The amplitude of these fluctuations changed in the three periods and was lower when the LF/HF RRI power ratio was higher, at O, thus suggesting a possible influence of the autonomic nervous system on LVET short-term variability. To the best of our knowledge this case report provides for the first time a representation of the beat-by-beat dynamics of a systolic time interval during daily activity. The statistical characterization of these findings remains to be explored on a larger population.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
There have been multiple previous works that have delved into using dual-mode ECG and SCG sensing for cardiac time intervals measurements.
“There have been multiple previous works that have delved into using dual-mode ECG and SCG sensing for cardiac time intervals measurements. [26-29]”
From A Chest‐Conformable, Wireless Electro‐Mechanical E‐Tattoo for Measuring Multiple Cardiac Time Intervals (2023) · cites this paper as [26]
The increase in PEP and decrease in LVET with posture change is well documented in prior literature and attributed to changes in preload, contractility, and afterload.
“The increase in PEP and the decrease in LVET is well documented in prior literature [26,47] and is attributed to changes in preload, contractility, and afterload.”
From A Chest‐Conformable, Wireless Electro‐Mechanical E‐Tattoo for Measuring Multiple Cardiac Time Intervals (2023) · cites this paper as [26]
Cites
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289 · see citing works
Systolic Time Intervals in Heart Failure in Man
WEISSLER, A. M., HARRIS, W. S., & SCHOENFELD, C. D. (1968) · Circulation · doi:10.1161/01.cir.37.2.149 · Cited by 1,217 · see citing works
New non-invasive index for combined systolic and diastolic ventricular function.
Tei, C. (1995) · PubMed · Cited by 688 · see citing works
Bedside technics for the evaluation of ventricular function in man
Weissler, A. M., Harris, W. S., & Schoenfeld, C. D. (1969) · The American Journal of Cardiology · doi:10.1016/0002-9149(69)90012-5 · Cited by 604 · see citing works
Martin, C. E., Shaver, J. A., Thompson, M. E., REDDY, P. S., & Leonard, J. J. (1971) · Circulation · doi:10.1161/01.cir.44.3.419 · Cited by 192 · see citing works
Relationship between Seismocardiogram and Echocardiogram for Events in the Cardiac Cycle
Crow, R. S., Hannan, P., Jacobs, D., Hedquist, L., & Salerno, D. M. (2017) · American Journal of Noninvasive Cardiology · doi:10.1159/000470156 · Cited by 186 · cited 2× · see citing works
“This annotation was proposed by Crow and colleagues (Crow et al., 1994) as result of a direct comparison of SCG displacements with echocardiographic images, where ATC = atrial contraction; MC = closure of mitral valve; AO = opening of aortic valve; MA = point of maximal blood acceleration in the…”
Ballistocardiography — A method worth revisiting
Giovangrandi, L., Inan, O. T., Wiard, R. M., Etemadi, M., & Kovacs, G. T. A. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091062 · Cited by 165 · see citing works
Castiglioni, P., Faini, A., Parati, G., & Rienzo, M. D. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353199 · Cited by 156 · see citing works
Self-citationSeismocardiography for Monitoring Changes in Left Ventricular Function during Ischemia
Salerno, D. M., & Zanetti, J. (1991) · Chest · doi:10.1378/chest.100.4.991 · Cited by 149 · see citing works
Computerized heart sounds analysis
Debbal, S. M. E. A., & Bereksi-Reguig, F. (2007) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2007.09.006 · Cited by 137 · see citing works
Réant, P., Dijos, M., Donal, E., Mignot, A., Ritter, P., Bordachar, P., Santos, P. D. D., Leclercq, C., Roudaut, R., Habib, G., et al. (2010) · European Journal of Echocardiography · doi:10.1093/ejechocard/jeq084 · Cited by 122 · see citing works
Effects of variation in posture and respiration on RSA and pre‐ejection period
Houtveen, J. H., Groot, P. F. C., & de Geus, E. J. C. (2005) · Psychophysiology · doi:10.1111/j.1469-8986.2005.00363.x · Cited by 88 · see citing works
Textile Technology for the Vital Signs Monitoring in Telemedicine and Extreme Environments
Rienzo, M. D., Meriggi, P., Rizzo, F., Castiglioni, P., Lombardi, C., Ferratini, M., & Parati, G. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2048921 · Cited by 88 · see citing works
Self-citationMcKusick, V. A., Webb, G. N., Humphries, J. O., & REID, J. A. (1955) · Circulation · doi:10.1161/01.cir.11.6.849 · Cited by 63 · see citing works
Wilson, R. A., Bamrah, V. S., Lindsay, J., Schwaiger, M., & Morganroth, J. (1993) · The American Journal of Cardiology · doi:10.1016/0002-9149(93)90508-a · Cited by 61 · see citing works
A wearable system for the seismocardiogram assessment in daily life conditions
Rienzo, M. D., Meriggi, P., Rizzo, F., Vaini, E., Faini, A., Merati, G., Parati, G., & Castiglioni, P. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091058 · Cited by 61 · see citing works
Self-citation[Seismocardiography--a new method in the study of functional conditions of the heart].
Bs, B. (1961) · PubMed · Cited by 60 · see citing works
The return of cardiac time intervals
Oh, J. K., & Tajik, J. A. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)01036-2 · Cited by 56 · see citing works
McKay, W. P. S., Gregson, P. H., McKay, B. W., & Militzer, J. (1999) · PubMed · Cited by 55 · see citing works
Mechanisms Underlying Isovolumic Contraction and Ejection Peaks in Seismocardiogram Morphology.
Gurev, V. (2011) · Journal of Medical and Biological Engineering · doi:10.5405/jmbe.847 · Cited by 47 · see citing works
Rienzo, M. D., Racca, V., Rizzo, F., Bordoni, B., Parati, G., Castiglioni, P., Meriggi, P., & Ferratini, M. (2012) · EP Europace · doi:10.1093/europace/eus368 · Cited by 45 · see citing works
Self-citationSystolic time intervals in clinical pharmacology
Li, Q., & Belz, G. G. (1993) · European Journal of Clinical Pharmacology · doi:10.1007/bf00315536 · Cited by 43 · see citing works
Marcus, G. M., Sorrell, V. L., Zanetti, J. M., Bosnos, M., Baweja, G., PERLICK, D., Ott, P., Indik, J. H., He, D. S., & Gear, K. (2007) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2007.00894.x · Cited by 41 · see citing works
Three-dimensional ballistocardiography and respiratory motion in sustained microgravity.
Prisk, G. K., Verhaeghe, S. T. L., Padeken, D., Hamacher, H., & Paiva, M. (2001) · PubMed · Cited by 40 · see citing works
Ballistocardiography in Cardiovascular Research.
Walker, W. J. (1968) · Archives of Internal Medicine · doi:10.1001/archinte.1968.03640040081043 · Cited by 39 · see citing works
Cardiac sounds from a wearable device for sternal seismocardiography
Castiglioni, P., Meriggi, P., Rizzo, F., Vaini, E., Faini, A., Parati, G., Merati, G., & Rienzo, M. D. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091063 · Cited by 39 · see citing works
Self-citationDeterminants of duration of left ventricular ejection in normal young men
Jones, W. B., & Foster, G. L. (1964) · Journal of Applied Physiology · doi:10.1152/jappl.1964.19.2.279 · Cited by 38 · see citing works
Three dimensional ballistocardiography: Methodology and results from microgravity and dry immersion
Migeotte, P., Tank, J., Pattyn, N., Funtova, I. I., Baevsky, R. M., Neyt, X., & Prisk, G. K. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091060 · Cited by 37 · see citing works
Skolidis, G., Clayton, R. H., & Sanguinetti, G. (2008) · CiteSeer X (The Pennsylvania State University) · Cited by 37 · see citing works
Exercise Seismocardiography for Detection of Coronary Artery Disease
Salerno, D. M., Zanetti, J. M., Poliac, L. C., Crow, R. S., Hannan, P. J., Wang, K., Goldenberg, I. F., & Tassel, R. A. V. (2017) · American Journal of Noninvasive Cardiology · doi:10.1159/000470383 · Cited by 35 · see citing works
24h seismocardiogram monitoring in ambulant subjects
Rienzo, M. D., Meriggi, P., Vaini, E., Castiglioni, P., & Rizzo, F. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6347128 · Cited by 34 · see citing works
Self-citationComparative analysis of seismocardiogram waves with the ultra-low frequency ballistocardiogram
Ngai, B., Tavakolian, K., Akhbardeh, A., Blaber, A. P., Kamińska, B., & Noordergraaf, A. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333649 · Cited by 25 · see citing works
Gemignani, V., Bianchini, E., Faita, F., Lionetti, V., Campan, M., Recchia, F. A., Picano, E., & Bombardini, T. (2010) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2009.02684.x · Cited by 19 · see citing works
Arterial pressure changes monitoring with a new precordial noninvasive sensor
Bombardini, T., Gemignani, V., Bianchini, E., Venneri, L., Petersen, C., Pasanisi, E., Pratali, L., Pianelli, M., Faita, F., Giannoni, M., et al. (2008) · Cardiovascular Ultrasound · doi:10.1186/1476-7120-6-41 · Cited by 16 · see citing works
Comparative analysis of infrasonic cardiac signals
Tavakolian, K., Ngai, B., Akhbardeh, A., Kamińska, B., & Blaber, A. P. (2009) · Computers in Cardiology Conference · Cited by 16 · see citing works
Lance, V. Q., & Spodick, D. H. (1976) · Heart · doi:10.1136/hrt.38.12.1332 · Cited by 15 · see citing works
Boudoulas, H., Barrington, W., Olson, S. M., Bashore, T. M., & Wooley, C. F. (1985) · American Heart Journal · doi:10.1016/0002-8703(85)90085-7 · Cited by 9 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Ballistocardiography and Seismocardiography: A Review of Recent Advances
Inan, O. T., Migeotte, P.-F., Park, K.-S., Etemadi, M., Tavakolian, K., Casanella, R., Zanetti, J., Tank, J., Funtova, I., Prisk, G. K., et al. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2361732 · Cited by 775 · see citing works
Chung, H. U., Rwei, A. Y., Hourlier-Fargette, A., Xu, S., Lee, K., Dunne, E. C., Xie, Z., Liu, C., Carlini, A., Kim, D. H., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-0792-9 · Cited by 482 · see citing works
Recent Advances in Seismocardiography
Taebi, A., Solar, B. E., Bomar, A. J., Sandler, R. H., & Mansy, H. A. (2019) · Vibration · doi:10.3390/vibration2010005 · Cited by 278 · see citing works
Contactless seismocardiography via deep learning radars
Ha, U., Assana, S., & Adib, F. (2020) · ACM Annual International Conference on Mobile Computing and Networking (MobiCom) · doi:10.1145/3372224.3419982 · Cited by 203 · see citing works
Tadi, M. J., Lehtonen, E., Saraste, A., Tuominen, J., Koskinen, J., Teräs, M., Airaksinen, J. K. E., Pänkäälä, M., & Koivisto, T. (2017) · Scientific Reports · doi:10.1038/s41598-017-07248-y · Cited by 175 · see citing works
Li, K. H. C., White, F. A., Tipoe, T., Liu, T., Wong, M. C. S., Jesuthasan, A., Baranchuk, A. M., Tse, G., & Yan, B. P. (2018) · JMIR mhealth and uhealth · doi:10.2196/11606 · Cited by 162 · see citing works
Advances in Respiratory Monitoring: A Comprehensive Review of Wearable and Remote Technologies
Vitazkova, D., Foltan, E., Kosnacova, H., Micjan, M., Donoval, M., Kuzma, A., Kopáni, M., & Vavrinský, E. (2024) · Biosensors · doi:10.3390/bios14020090 · Cited by 149 · see citing works
Definition of Fiducial Points in the Normal Seismocardiogram
Sørensen, K., Schmidt, S. E., Jensen, A. S., Søgaard, P., & Struijk, J. J. (2018) · Scientific Reports · doi:10.1038/s41598-018-33675-6 · Cited by 111 · see citing works
Heart monitoring systems—A review
Jain, P. K., & Tiwari, A. K. (2014) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2014.08.014 · Cited by 101 · see citing works
A real-time approach for heart rate monitoring using a Hilbert transform in seismocardiograms
Tadi, M. J., Lehtonen, E., Hurnanen, T., Koskinen, J., Eriksson, J., Pänkäälä, M., Teräs, M., & Koivisto, T. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/11/1885 · Cited by 98 · see citing works
Flexible sensors and machine learning for heart monitoring
Kwon, S. H., & Dong, L. (2022) · Nano Energy · doi:10.1016/j.nanoen.2022.107632 · Cited by 98 · see citing works
Etemadi, M., Inan, O. T., Heller, J. A., Hersek, S., Klein, L., & Roy, S. (2016) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2015.2405480 · Cited by 95 · see citing works
“Recently, several researchers have developed wearable systems for measuring SCG signals during normal activities of daily living using micromachined (MEMS) accelerometers, including a wearable vest for SCG measurement in the field and during sleep [10], [11], a flexible patch with SCG and electrocardiogram (ECG) measu…”
Surface Chest Motion Decomposition for Cardiovascular Monitoring
Shafiq, G., & Veluvolu, K. C. (2014) · Scientific Reports · doi:10.1038/srep05093 · Cited by 92 · see citing works
A multi-point heart rate monitoring using a soft wearable system based on fiber optic technology
Presti, D. L., Santucci, F., Massaroni, C., Formica, D., Setola, R., & Schena, E. (2021) · Scientific Reports · doi:10.1038/s41598-021-00574-2 · Cited by 87 · see citing works
Barvik, D., Černý, M., Penhaker, M., & Noury, N. (2021) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2021.3109643 · Cited by 85 · see citing works
Khosrow-Khavar, F., Tavakolian, K., Blaber, A. P., & Menon, C. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2616382 · Cited by 82 · see citing works
Dehkordi, P., Khosrow-Khavar, F., Rienzo, M. D., Inan, O. T., Schmidt, S. E., Blaber, A. P., Sørensen, K., Struijk, J. J., Zakeri, V., Lombardi, P., et al. (2019) · Frontiers in Physiology · doi:10.3389/fphys.2019.01057 · Cited by 82 · see citing works
A Cardiac Early Warning System with Multi Channel SCG and ECG Monitoring for Mobile Health
Sahoo, P., Thakkar, H., & Lee, M.-Y. (2017) · Sensors · doi:10.3390/s17040711 · Cited by 81 · see citing works
Klum, M., Urban, M., Tigges, T., Pielmus, A.-G., Feldheiser, A., Schmitt, T., & Orglmeister, R. (2020) · Sensors · doi:10.3390/s20072033 · Cited by 75 · see citing works
An Overview of the Sensors for Heart Rate Monitoring Used in Extramural Applications
Galli, A., Montree, R. J. H., Que, S., Peri, E., & Vullings, R. (2022) · Sensors · doi:10.3390/s22114035 · Cited by 79 · see citing works
Wang, L., Huang, K., Sun, K., Wang, W., Tian, C., Xie, L., & Gu, Q. (2018) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3264950 · Cited by 77 · see citing works
Sahoo, P. K., Thakkar, H. K., Lin, W., Chang, P., & Lee, M. (2018) · Sensors · doi:10.3390/s18020379 · Cited by 76 · see citing works
Shandhi, M. M. H., Semiz, B., Hersek, S., Goller, N., Ayazi, F., & Inan, O. T. (2019) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2895775 · Cited by 74 · see citing works
Wiens, A. D., Etemadi, M., Roy, S., Klein, L., & Inan, O. T. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2359937 · Cited by 69 · see citing works
Systolic Time Intervals and New Measurement Methods
Tavakolian, K. (2016) · Cardiovascular Engineering and Technology · doi:10.1007/s13239-016-0262-1 · Cited by 69 · see citing works
Automatic Identification of Systolic Time Intervals in Seismocardiogram
Shafiq, G., Tatinati, S., Ang, W. T., & Veluvolu, K. C. (2016) · Scientific Reports · doi:10.1038/srep37524 · Cited by 68 · see citing works
Automatic Detection of Aortic Valve Opening Using Seismocardiography in Healthy Individuals
Choudhary, T., Sharma, L. N., & Bhuyan, M. K. (2018) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2018.2829608 · Cited by 67 · see citing works
Seismocardiography: Toward heart rate variability (HRV) estimation
Tadi, M. J., Lehtonen, E., Koivisto, T., Pänkäälä, M., Paasio, A., & Teräs, M. (2015) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2015.7145210 · Cited by 62 · see citing works
Skin-interfaced wireless biosensors for perinatal and paediatric health
Kim, J., Yoo, S., Liu, C. Y., Kwak, S. S., Walter, J. R., Xu, S., & Rogers, J. A. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00090-0 · Cited by 64 · see citing works
Chest-Worn Inertial Sensors: A Survey of Applications and Methods
Rahmani, M. H., Berkvens, R., & Weyn, M. (2021) · Sensors · doi:10.3390/s21082875 · Cited by 56 · see citing works
Balali, P., Rabineau, J., Hossein, A., Tordeur, C., Debeir, O., & van de Borne, P. (2022) · Sensors · doi:10.3390/s22239565 · Cited by 49 · see citing works
A Unified Framework for Quality Indexing and Classification of Seismocardiogram Signals
Zia, J., Kimball, J., Hersek, S., Shandhi, M. M. H., Semiz, B., & Inan, O. T. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2931348 · Cited by 48 · see citing works
“A major limitation of SCG for outpatient continuous monitoring is its sensitivity to noise due to motion artifacts [6].”
BackgroundJacobs, F. E. N. B., Scheerhoorn, J., Mestrom, E. H. J., van der Stam, J. A., Bouwman, R. A., & Nienhuijs, S. W. (2021) · PLoS ONE · doi:10.1371/journal.pone.0247903 · Cited by 45 · see citing works
Rienzo, M. D., Rizzo, F., Isilay, Z. M., & Lombardi, P. (2020) · Sensors · doi:10.3390/s20030680 · Cited by 44 · see citing works
Self-citationECG-Free Heartbeat Detection in Seismocardiography Signals via Template Matching
Centracchio, J., Parlato, S. J., Esposito, D., Bifulco, P., & Andreozzi, E. (2023) · Sensors · doi:10.3390/s23104684 · Cited by 44 · see citing works
Lee, H., Lee, H., & Whang, M. (2018) · Sensors · doi:10.3390/s18010238 · Cited by 42 · see citing works
Bhattacharya, S., Nikbakht, M., Alden, A., Tan, P., Wang, J., Alhalimi, T. A., Kim, S., Wang, P., Tanaka, H., Tandon, A., et al. (2023) · Advanced Electronic Materials · doi:10.1002/aelm.202201284 · Cited by 42 · see citing works
An Independent Component Analysis Approach to Motion Noise Cancelation of Cardio-Mechanical Signals
Yang, C., & Tavassolian, N. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2856700 · Cited by 41 · see citing works
Lin, W., Ke, H.-L., Chou, W.-C., Chang, P., Tsai, T.-H., & Lee, M. (2018) · Sensors · doi:10.3390/s18103538 · Cited by 40 · see citing works
Reducing the Impact of External Vibrations on Fiducial Point Detection in Seismocardiogram Signals
Lin, D. J., Kimball, J. P., Zia, J. S., Ganti, V. G., & Inan, O. T. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3090376 · Cited by 39 · see citing works
Rienzo, M. D., Vaini, E., & Lombardi, P. (2018) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2018.02.034 · Cited by 38 · see citing works
Self-citationRienzo, M. D., Vaini, E., & Lombardi, P. (2017) · Scientific Reports · doi:10.1038/s41598-017-15829-0 · Cited by 37 · see citing works
Self-citationHeart Sound Extraction From Sternal Seismocardiographic Signal
Choudhary, T., Sharma, L. N., & Bhuyan, M. K. (2018) · IEEE Signal Processing Letters · doi:10.1109/lsp.2018.2801341 · Cited by 37 · see citing works
Romano, C., Formica, D., Schena, E., & Massaroni, C. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3245415 · Cited by 34 · see citing works
Smartphone accelerometers for the detection of heart rate
Landreani, F., & Caiani, E. G. (2017) · Expert Review of Medical Devices · doi:10.1080/17434440.2017.1407647 · Cited by 34 · see citing works
A Novel Method for Aortic Valve Opening Phase Detection Using SCG Signal
Choudhary, T., Bhuyan, M. K., & Sharma, L. N. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2944235 · Cited by 34 · see citing works
Accuracy of vital parameters measured by a wearable patch following major abdominal cancer surgery
van der Stam, J. A., Mestrom, E. H. J., Scheerhoorn, J., Jacobs, F. E. N. B., de Hingh, I. H. J. T., van Riel, N. A. W., Boer, A., Scharnhorst, V., Nienhuijs, S. W., & Bouwman, R. A. (2021) · European Journal of Surgical Oncology · doi:10.1016/j.ejso.2021.10.034 · Cited by 36 · see citing works
Smart Sleep Monitoring System via Passively Sensing Human Vibration Signals
Li, F., Valero, M., Clemente, J. M., Tse, Z. T. H., & Song, W. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3013435 · Cited by 33 · see citing works
Mohamed, R., & Youssef, M. A. (2017) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3132028 · Cited by 33 · see citing works
Automatic annotation of peaks in seismocardiogram for systolic time intervals
Shafiq, G., Tatinati, S., & Veluvolu, K. C. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591280 · Cited by 31 · see citing works
Hersek, S., Semiz, B., Shandhi, M. M. H., Orlandic, L., & Inan, O. T. (2019) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2931872 · Cited by 30 · see citing works
A Novel System Identification Technique for Improved Wearable Hemodynamics Assessment
Wiens, A. D., & Inan, O. T. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2387354 · Cited by 29 · see citing works
Non-contact heart vibration measurement using computer vision-based seismocardiography
Rahman, M. M., Cook, J., & Taebi, A. (2023) · Scientific Reports · doi:10.1038/s41598-023-38607-7 · Cited by 28 · see citing works
Fully Automated Annotation of Seismocardiogram for Noninvasive Vital Sign Measurements
Mora, N., Cocconcelli, F., Matrella, G., & Ciampolini, P. (2019) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2019.2908511 · Cited by 27 · see citing works
Multimodal chest surface motion data for respiratory and cardiovascular monitoring applications
Shafiq, G., & Veluvolu, K. C. (2017) · Scientific Data · doi:10.1038/sdata.2017.52 · Cited by 28 · see citing works
Parlato, S. J., Centracchio, J., Esposito, D., Bifulco, P., & Andreozzi, E. (2023) · Sensors · doi:10.3390/s23198114 · Cited by 27 · see citing works
Performance analysis of seismocardiography for heart sound signal recording in noisy scenarios
Jain, P. K., Tiwari, A. K., & Chourasia, V. S. (2016) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2016.1139203 · Cited by 25 · see citing works
Yao, J., Tridandapani, S., Auffermann, W. F., Wick, C. A., & Bhatti, P. T. (2018) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2018.2869141 · Cited by 24 · see citing works
Khamis, A., Chou, C. T., Kusý, B., & Hu, W. S. (2018) · EAI International Conference on Mobile and Ubiquitous Systems: Computing, Networking and Services (MobiQuitous) · doi:10.1145/3286978.3287003 · Cited by 24 · see citing works
Cuffless and Continuous Blood Pressure Monitoring Using a Single Chest-Worn Device
Park, J., Yang, S.-M., Sohn, J., Lee, J., Lee, S., Ku, Y., & Kim, H. C. (2019) · IEEE Access · doi:10.1109/access.2019.2942184 · Cited by 25 · see citing works
Hossein, A., Rabineau, J., Gorlier, D., Rio, J. I. J. D., van de Borne, P., Migeotte, P., & Nonclercq, A. (2021) · Sensors · doi:10.3390/s21030815 · Cited by 24 · see citing works
Heartbeat Detection in Gyrocardiography Signals without Concurrent ECG Tracings
Parlato, S. J., Centracchio, J., Esposito, D., Bifulco, P., & Andreozzi, E. (2023) · Sensors · doi:10.3390/s23136200 · Cited by 23 · see citing works
Isilay, Z. M., Racca, V., Pezzano, A., Tavanelli, M., & Rienzo, M. D. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.825918 · Cited by 22 · see citing works
Hoffmann, B., Dehkordi, P., Khosrow-Khavar, F., Goswami, N., Blaber, A. P., & Tavakolian, K. (2022) · npj Microgravity · doi:10.1038/s41526-022-00206-7 · Cited by 22 · see citing works
Yao, J., Tridandapani, S., Wick, C. A., & Bhatti, P. T. (2017) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2017.2708100 · Cited by 22 · see citing works
Autocorrelated Differential Algorithm for Real-Time Seismocardiography Analysis
D’Mello, Y., Skoric, J., Xu, S., Akhras, M., Roche, P. J. R., Lortie, M. A., Gagnon, S., & Plant, D. V. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2903449 · Cited by 22 · see citing works
Electrocardiogram Devices for Home Use: Technological and Clinical Scoping Review
Zepeda-Echavarria, A., van de Leur, R. R., van Sleuwen, M., Hassink, R. J., Wildbergh, T. X., Doevendans, P. A., Jaspers, J., & van Es, R. (2023) · JMIR Cardio · doi:10.2196/44003 · Cited by 24 · see citing works
Simple Heart Rate Monitoring System with a MEMS Gyroscope for Sleep Studies
Hernandez, J. E., & Cretu, E. (2018) · IEEE Annual Information Technology, Electronics and Mobile Communication Conference (IEMCON) · doi:10.1109/iemcon.2018.8614753 · Cited by 21 · see citing works
Kimball, J. P., Inan, O. T., Convertino, V. A., Cardin, S., & Sawka, M. N. (2022) · Sensors · doi:10.3390/s22020442 · Cited by 19 · see citing works
Respiratory Modulation of Sternal Motion in the Context of Seismocardiography
Skoric, J., D’Mello, Y., Aboulezz, E., Hakim, S., Clairmonte, N., Lortie, M. A., & Plant, D. V. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3173205 · Cited by 18 · see citing works
Changes in Forcecardiography Heartbeat Morphology Induced by Cardio-Respiratory Interactions
Centracchio, J., Esposito, D., Gargiulo, G. D., & Andreozzi, E. (2022) · Sensors · doi:10.3390/s22239339 · Cited by 18 · see citing works
Seismocardiography-Based Detection of Cardiac Quiescence
Wick, C. A., Inan, O. T., McClellan, J. H., & Tridandapani, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2411155 · Cited by 18 · see citing works
A textile-based wearable system for the prolonged assessment of cardiac mechanics in daily life
Rienzo, M. D., Vaini, E., Castiglioni, P., Lombardi, P., Meriggi, P., & Rizzo, F. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6945213 · Cited by 18 · see citing works
Self-citationA Wavelet-Based Approach for Motion Artifact Reduction in Ambulatory Seismocardiography
Skoric, J., D’Mello, Y., & Plant, D. V. (2024) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2024.3368291 · Cited by 20 · see citing works
High-Accuracy, Unsupervised Annotation of Seismocardiogram Traces for Heart Rate Monitoring
Cocconcelli, F., Mora, N., Matrella, G., & Ciampolini, P. (2020) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2020.2967135 · Cited by 17 · see citing works
Identification of Human Breathing-States Using Cardiac-Vibrational Signal for m-Health Applications
Choudhary, T., Sharma, L. N., Bhuyan, M. K., & Bora, K. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3025384 · Cited by 16 · see citing works
Delineation and Analysis of Seismocardiographic Systole and Diastole Profiles
Choudhary, T., Bhuyan, M. K., & Sharma, L. N. (2020) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2020.3007295 · Cited by 16 · see citing works
A Differential BCG Sensor System for Long Term Health Monitoring Experiment on the ISS
Kulau, U., Rust, J., Szafranski, D., Drobczyk, M., & Albrecht, U. (2022) · International Conference on Distributed Computing in Smart Systems and the Internet of Things (DCOSS-IoT) · doi:10.1109/dcoss54816.2022.00028 · Cited by 16 · see citing works
Heart Rate Estimated from Body Movements at Six Degrees of Freedom by Convolutional Neural Networks
Lee, H., & Whang, M. (2018) · Sensors · doi:10.3390/s18051392 · Cited by 16 · see citing works
Ebrahimkhani, M., Johnson, E., Sodhi, A., Robinson, J. D., Rigsby, C. K., Allen, B. D., & Markl, M. (2023) · Annals of Biomedical Engineering · doi:10.1007/s10439-023-03342-7 · Cited by 15 · see citing works
Javaid, A. Q., Fesmire, N. F., Weitnauer, M. A., & Inan, O. T. (2015) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2015.7299377 · Cited by 15 · see citing works
Motion noise cancellation in seismocardiographic monitoring of moving subjects
Yang, C., & Tavassolian, N. (2015) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2015.7348361 · Cited by 15 · see citing works
Motion noise cancellation in seismocardiogram of ambulant subjects with dual sensors
Yang, C., & Tavassolian, N. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7592066 · Cited by 15 · see citing works
Assessment of Fetal Development Using Cardiac Valve Intervals
Marzbanrad, F., Khandoker, A. H., Kimura, Y., Palaniswami, M. S., & Clifford, G. D. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2017.00313 · Cited by 15 · see citing works
Orthogonal subspace projection based framework to extract heart cycles from SCG signal
Choudhary, T., Bhuyan, M. K., & Sharma, L. N. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.01.005 · Cited by 15 · see citing works
A novel method for suppression of motion artifacts from the seismocardiogram signal
Jain, P. K., & Tiwari, A. K. (2016) · IEEE International Conference on Digital Signal Processing (DSP) · doi:10.1109/icdsp.2016.7868504 · Cited by 15 · see citing works
Detecting Aortic Valve-Induced Abnormal Flow with Seismocardiography and Cardiac MRI
Johnson, E. M. I., Heller, J. A., Garcia Vicente, F., Sarnari, R., Gordon, D., McCarthy, P. M., Barker, A. J., Etemadi, M., & Markl, M. (2020) · Annals of Biomedical Engineering · doi:10.1007/s10439-020-02491-3 · Cited by 14 · see citing works
An Approach of Heartbeat Segmentation in Seismocardiogram by Matched-Filtering
Li, Y., Tang, X., & Xu, Z. F. (2015) · International Conference on Intelligent Human-Machine Systems and Cybernetics · doi:10.1109/ihmsc.2015.157 · Cited by 14 · see citing works
Robust Detection of AO and IM Points in the Seismocardiogram Using CWT
Rivero-Pouymiró, I., Valdés, E., & Valdés-Pérez, F. E. (2016) · IEEE Latin America Transactions · doi:10.1109/tla.2016.7795816 · Cited by 14 · see citing works
A Precise, Parallel and Scalable Measurement System for Ballistocardiographic Research
Clausen, T., Jura, T., Jähne-Raden, N., Wolf, M. C., Wolf, L. C., & Kulau, U. (2020) · Smart Health · doi:10.1016/j.smhl.2020.100169 · Cited by 14 · see citing works
Drobczyk, M., Lübken, A., Strowik, C., Kulau, U., Rust, J., Beringer, J., & Albrecht, U. (2021) · IEEE International Conference on Wireless for Space and Extreme Environments (WiSEE) · doi:10.1109/wisee50203.2021.9613824 · Cited by 14 · see citing works
Accurate Blood Pressure Measurement Using Smartphone's Built-in Accelerometer
Wang, L., Wang, X., Zhang, Y., Ma, X., Dai, H., Zhang, Y., Li, Z., & Gu, T. (2024) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3659599 · Cited by 13 · see citing works
Hossein, A., Rabineau, J., Gorlier, D., Pinky, F., van de Borne, P., Nonclercq, A., & Migeotte, P. (2021) · BioMedical Engineering OnLine · doi:10.1186/s12938-020-00837-5 · Cited by 13 · see citing works
Systolic time intervals assessed from analysis of the carotid pressure waveform
Salvi, P., Grillo, A., Tan, I., Simon, G., Salvi, L., Gao, L., Rovina, M., Butlin, M., Yang, Y., Meneghin, E., et al. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aad51b · Cited by 13 · see citing works
Self-citationStandalone Heartbeat Extraction in SCG Signal Using Variational Mode Decomposition
Choudhary, T., Sharma, L. N., & Bhuyan, M. K. (2018) · International Conference on Wireless Communications, Signal Processing and Networking (WiSPNET) · doi:10.1109/wispnet.2018.8538723 · Cited by 13 · see citing works
Wang, J., Foster, M., Bozkurt, A. Y., & Roberts, D. L. (2022) · International Conference on Animal-Computer Interaction (ACI) · doi:10.1145/3565995.3566037 · Cited by 12 · see citing works
Chen, C., Lin, W., & Lee, M. (2020) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc42975.2020.9283120 · Cited by 12 · see citing works
Parlato, S., Centracchio, J., Esposito, D., Bifulco, P., & Andreozzi, E. (2025) · Physical and Engineering Sciences in Medicine · doi:10.1007/s13246-025-01531-3 · Cited by 11 · see citing works
Wearable seismocardiography for the beat-to-beat assessment of cardiac intervals during sleep
Rienzo, M. D., Vaini, E., Castiglioni, P., Lombardi, P., Parati, G., Lombardi, C., Meriggi, P., & Rizzo, F. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6945018 · Cited by 11 · see citing works
Self-citationDetermining Heart Rate Beat-to-Beat from Smartphone Seismocardiograms: Preliminary Studies
Sieciński, S., & Kostka, P. (2017) · Advances in intelligent systems and computing · doi:10.1007/978-3-319-70063-2_15 · Cited by 11 · see citing works
- Authors
- Di Rienzo, M., Vaini, E., Castiglioni, P., Merati, G., Meriggi, P., Parati, G., Faini, A., & Rizzo, F.
- Affiliations
- Don Carlo Gnocchi Foundation (IT)
- University of Milan (IT)
- University of Milano-Bicocca (IT)
- Venue
- Autonomic Neuroscience
- Publisher
- Elsevier BV
- Published
- 2013-11
- Volume
- 178
- Issue
- 1-2
- Pages
- 50-59
- ISSN
- 1566-0702 (ISSN-L)
- OpenAlex
- W2007729863
- Cited by
- 163
- References
- 37
- Citations by year
- 2026: 5 · 2025: 8 · 2024: 12 · 2023: 19 · 2022: 19 · 2021: 11 · 2020: 20 · 2019: 13 · 2018: 19 · 2017: 10 · 2016: 11 · 2015: 7 · 2014: 8 · 2013: 1
- FWCI
- 4.97
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Autonomic Neuroscience (publishedVersion)
- PubMed (publishedVersion)
- BOA (University of Milano-Bicocca) (submittedVersion)
- IrInSubria (University of Insubria) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Phonocardiography and Auscultation Techniques
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- seismocardiography, wearable cardiac monitoring, smart garments, cardiac contractility, pre-ejection period, left ventricular ejection time, aortic valve opening, heart rate variability, daily activity monitoring
- MeSH terms
- Acceleration, Adult, Ambulances, Ballistocardiography, Female, Heart Rate, Humans, Male, Myocardial Contraction, Plethysmography, Posture, Signal Processing, Computer-Assisted, Electrocardiography, Ambulatory, Wireless Technology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review