The DOI matches its Crossref record.
Atrioventricular Conduction Defects in Patients with Sinus Bradycardia: Analysis by His Bundle Recordings
Abstract
A-V conduction was analyzed in 75 patients (mean age, 73 years) with sinus bradycardia (SB) by His bundle (BH) recordings. Forty-five of these patients had normal QRS complexes (≦0.10 sec) and 30 had abnormal QRS complexes (≧0.12 sec). The conduction times through the atrium (P-A), A-V node (A-H), and His-Purkinje system (H-V) were measured during normal sinus rhythm and transient right atrial pacing up to rates of 150/min. The normal range of conduction times through various regions is: P-A = 25 to 45 msec; A-H = 50 to 120 msec, and H-V = 35 to 45 msec. Overall A-V conduction was completely normal only in 25 (33%) patients. Of these 25 patients, 20 had a narrow QRS complex and five had an abnormal QRS complex. The remaining 50 patients showed abnormal A-V conduction in one or more regions (P-A in 10, A-H in five, BH in six, H-V in 10, and mixed in 19). In some patients despite normal ECGs, the H-V time was abnormal and 1:1 A-V conduction was present during atrial pacing up to 150/min. An abnormal H-V time in association with a normal QRS complex is suggestive of delay in the His bundle. Fourteen patients were restudied at intervals of 6 months to 2 years. Three of these 14 patients showed prolongation of conduction times over 1½ to 2 years. Our data demonstrate that SB is often (67%) associated with A-V conduction abnormalities. A-V conduction was abnormal in 56% of patients with normal and 83% with abnormal QRS complexes. The ECG and atrial pacing are of limited value in assessing A-V conduction. The BH recordings in symptomatic patients with sinus bradycardia may be of clinical significance in the selection of site for pacemaker implantation, that is, atrial or ventricular.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Rosenqvist, M., Brandt, J., & Schüller, H. (1988) · American Heart Journal · doi:10.1016/0002-8703(88)90244-x · Cited by 446
SASAKI, Y., SHIMOTORI, M., AKAHANE, K., YONEKURA, H., HIRANO, K., ENDOH, R., KOIKE, S., KAWA, S., FURUTA, S., & HOMMA, T. (1988) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1988.tb06277.x · Cited by 109
Sick Sinus Syndrome Treated with Permanent Pacemaker in 109 Patients: A Follow‐Up Study
Breivik, K., Ohm, O., & Segadal, L. (1979) · Acta Medica Scandinavica · doi:10.1111/j.0954-6820.1979.tb13486.x · Cited by 73
KHAYKIN, Y., MARROUCHE, N. F., MARTIN, D. O., SALIBA, W., SCHWEIKERT, R., WEXMAN, M., STRUNK, B., BEHEIRY, S., SAAD, E., BHARGAVA, M., et al. (2004) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2004.03279.x · Cited by 49
Metadata
- Authors
- NARULA, O. S.
- Venue
- Circulation
- Published
- 1971-12
- Volume
- 44
- Issue
- 6
- Pages
- 1096-1110
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2035974530
- Cited by
- 158
- References
- 0
- FWCI
- 9.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Atrioventricular Conduction Defects in Patients with Sinus Bradycardia: Analysis by His Bundle Recordings. https://app.cochat.ai/papers/10.1161/01.cir.44.6.1096
- The paper
- NARULA, O. S. (1971). Atrioventricular Conduction Defects in Patients with Sinus Bradycardia: Analysis by His Bundle Recordings. Circulation. https://doi.org/10.1161/01.cir.44.6.1096
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.