Noninvasive determination of left ventricular end-systolic stress: validation of the method and initial application.

Open access
Reichek, N, Wilson, J, St John Sutton, M, Plappert, T A, Goldberg, S, Hirshfeld, J W·1982·Circulation

Abstract

End-systolic left ventricular (LV) meridional wall stress is a quantitative index of true myo- cardial afterload that can be plotted against LV end-systolic diameter to give an index of contractility independent of loading conditions.We developed a noninvasive method for estimating end-systolic LV meridional wall stress based on M-mode LV echographic end-systolic diameter (LVID) and posterior wall thickness (PWT) and cuff systolic arterial pressure and compared it to simultaneous invasive LV wall stress derived from micromanometer LV pressure recordings and continuously digitized echograms in 12 subjects (four with atypical chest pain, six with severe aortic regurgitation (AR) and two with congestive cardiomyopathy), before and after load manipulation with nitroprusside, nitroglycerin, phenylephrine or saline.Cuff systolic pressure correlated well with end-systolic LV micromanometer pressure (r = 0.89, n = 31, range 96-160 mm Hg) and noninvasive end-systolic stress (0.334 P(LVID)/PWT [1 + PWT/LVID]) correlated extremely well with in- vasive stress (r = 0.97, n = 31, range 36-213 X 109 dyn/cm2).Invasive and noninvasive slopes (r = 0.91, n = 7) and LVID intercepts (r 0.89, n = 7) of the stress-diameter plots also correlated well.Noninvasive stress- diameter plots in nine normal subjects showed a range of slopes of 50-93 X 101 dyn/cm and intercepts of 1.8-2.8cm.Mean basal end-systolic noninvasive stress in 22 normal subjects (64.8 ± 19.5 X 10W dyn/cm2) and 14 treated hypertensives (56.3 ± 26.7 X 103 dyn/cm2) was significantly lower than in nine patients with symp- tomatic aortic regurgitation who had reduced ejection fraction (142.2 ± 53.2 X 10o dyn/cm2,p < 0.01) or four patients with congestive cardiomyopathy (187.3 ± 49.8 X 103 dyn/cm2, p < 0.01), while a mild elevation of stress in symptomatic aortic regurgitation with normal ejection fraction was not statistically significant (91.1 ± 20.7 X 103 dyn/cm2, n = 6).Thus, afterload excess contributed to ejection fraction reduction.We conclude that end-systolic stress may be determined noninvasively and may be a useful approach to quantitation of LV afterload and contractility.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.65.1.99

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 655

Metadata

Authors
Reichek, N., Wilson, J., St John Sutton, M., Plappert, T. A., Goldberg, S., & Hirshfeld, J. W.
Venue
Circulation
Published
1982-01
Volume
65
Issue
1
Pages
99-108
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2027555503
Cited by
655
References
1
FWCI
12.07
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Noninvasive determination of left ventricular end-systolic stress: validation of the method and initial application. https://app.cochat.ai/papers/10.1161/01.cir.65.1.99
The paper
Reichek, N., Wilson, J., St John Sutton, M., Plappert, T. A., Goldberg, S., & Hirshfeld, J. W. (1982). Noninvasive determination of left ventricular end-systolic stress: validation of the method and initial application. Circulation. https://doi.org/10.1161/01.cir.65.1.99

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.