The DOI matches its Crossref record.
Noninvasive evaluation of pulmonary hypertension by a pulsed Doppler technique.
Abstract
We used a pulsed Doppler technique to examine the flow velocity pattern in the right ventricular outflow tract in 33 adults. In the patients with normal pulmonary artery pressure (mean pressure less than 20 mm Hg, 16 patients), ejection flow reached a peak level at midsystole (137 +/- 24 msec, mean +/- SD), producing a domelike contour of the flow velocity pattern during systole. In contrast, the flow velocity pattern in patients with pulmonary hypertension (mean pressure greater than or equal to 20 mm Hg, 17 patients) was demonstrated to accelerate rapidly and to reach a peak level sooner (97 +/- 20 msec, p less than .01); in 10 of the pulmonary hypertensive patients a secondary slower rise in flow velocity was observed during a deceleration, resulting in the midsystolic notching. The time to peak flow (acceleration time, AcT) and right ventricular ejection time (RVET) were measured from the flow velocity pattern. Either AcT or AcT/RVET decreased with increase in mean pulmonary artery pressure, and a very high correlation (r = -.90) was found between AcT/RVET and log10 (mean pulmonary artery pressure). The use of this technique permitted the noninvasive estimation of the pulmonary artery pressure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Yock, P. G., & Popp, R. L. (1984) · Circulation · doi:10.1161/01.cir.70.4.657 · Cited by 1,640
Abman, S. H., Hansmann, G., Archer, S. L., Ivy, D. D., Adatia, I., Chung, W. K., Hanna, B. D., Rosenzweig, E. B., Raj, J. U., Cornfield, D., et al. (2015) · Circulation · doi:10.1161/cir.0000000000000329 · Cited by 1,164
Accuracy of Doppler Echocardiography in the Hemodynamic Assessment of Pulmonary Hypertension
Fisher, M. R., Forfia, P. R., Chamera, E., Housten-Harris, T., Champion, H. C., Girgis, R. E., Corretti, M. C., & Hassoun, P. M. (2009) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200811-1691oc · Cited by 1,075
Screening, Early Detection, and Diagnosis of Pulmonary Arterial Hypertension
McGoon, M., Gutterman, D., Steen, V., Barst, R., McCrory, D. C., Fortin, T. A., & Loyd, J. E. (2004) · Chest · doi:10.1378/chest.126.1_suppl.14s · Cited by 932
Berger, M., Haimowitz, A., Van Tosh, A., Berdoff, R. L., & Goldberg, E. (1985) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(85)80172-8 · Cited by 742
Tello, K., Wan, J., Dalmer, A., Vanderpool, R., Ghofrani, H. A., Naeije, R., Roller, F., Mohajerani, E., Seeger, W., Herberg, U., et al. (2019) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.119.009047 · Cited by 599
Spectrum of Cardiac Manifestations in COVID-19: A Systematic Echocardiographic Study
Szekely, Y., Lichter, Y., Taieb, P., Banai, A., Hochstadt, A., Merdler, I., Gal Oz, A., Rothschild, E., Baruch, G., Peri, Y., et al. (2020) · Circulation · doi:10.1161/circulationaha.120.047971 · Cited by 590
Pediatric Pulmonary Hypertension
Ivy, D. D., Abman, S. H., Barst, R. J., Berger, R. M. F., Bonnet, D., Fleming, T. R., Haworth, S. G., Raj, J. U., Rosenzweig, E. B., Schulze Neick, I., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.10.028 · Cited by 536
Neilan, T. G., Januzzi, J. L., Lee-Lewandrowski, E., Ton-Nu, T.-T., Yoerger, D. M., Jassal, D. S., Lewandrowski, K. B., Siegel, A. J., Marshall, J. E., Douglas, P. S., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.647461 · Cited by 519
Echocardiography in Pulmonary Arterial Hypertension: from Diagnosis to Prognosis
Bossone, E., D’Andrea, A., D’Alto, M., Citro, R., Argiento, P., Ferrara, F., Cittadini, A., Rubenfire, M., & Naeije, R. (2013) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2012.10.009 · Cited by 475
Champion, H. C., Michelakis, E. D., & Hassoun, P. M. (2009) · Circulation · doi:10.1161/circulationaha.106.674028 · Cited by 468
Comparison of three Doppler ultrasound methods in the prediction of pulmonary artery pressure
Chan, K.-L., Currie, P. J., Seward, J. B., Hagler, D. J., Mair, D. D., & Jamil Tajik, A. (1987) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(87)80047-5 · Cited by 390
Casanova, C., Celli, B. R., Tost, L., Soriano, E., Abreu, J., Velasco, V., & Santolaria, F. (2000) · Chest · doi:10.1378/chest.118.6.1582 · Cited by 350
Smiseth, O. A., Morris, D. A., Cardim, N., Cikes, M., Delgado, V., Donal, E., Flachskampf, F. A., Galderisi, M., Gerber, B. L., Gimelli, A., et al. (2022) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jeab154 · Cited by 347
Quantification of right ventricular afterload in patients with and without pulmonary hypertension
Lankhaar, J.-W., Westerhof, N., Faes, T. J. C., Marques, K. M. J., Marcus, J. T., Postmus, P. E., & Vonk-Noordegraaf, A. (2006) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00336.2006 · Cited by 338
Haemodynamic evaluation of pulmonary hypertension
Chemla, D., Castelain, V., Hervé, P., Lecarpentier, Y., & Brimioulle, S. (2002) · European Respiratory Journal · doi:10.1183/09031936.02.00068002 · Cited by 337
Augustine, D. X., Coates-Bradshaw, L. D., Willis, J., Harkness, A., Ring, L., Grapsa, J., Coghlan, G., Kaye, N., Oxborough, D., Robinson, S., et al. (2018) · Echo Research & Practice · doi:10.1530/erp-17-0071 · Cited by 333
Assessment of pulmonary artery pressure by echocardiography—A comprehensive review
Parasuraman, S., Walker, S., Loudon, B. L., Gollop, N. D., Wilson, A. M., Lowery, C., & Frenneaux, M. P. (2016) · IJC Heart & Vasculature · doi:10.1016/j.ijcha.2016.05.011 · Cited by 273
Pirat, B., McCulloch, M. L., & Zoghbi, W. A. (2006) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2006.03.056 · Cited by 272
Doppler Echocardiography: Theory, Instrumentation, Technique, and Application
NISHIMURA, R. A., MILLER, F. A., CALLAHAN, M. J., BENASSI, R. C., SEWARD, J. B., & TAJIK, A. J. (1985) · Mayo Clinic Proceedings · doi:10.1016/s0025-6196(12)60540-0 · Cited by 263
World Interactive Network Focused On Critical UltraSound ECHO-ICU Group, Price, S., Via, G., Sloth, E., Guarracino, F., Breitkreutz, R., Catena, E., & Talmor, D. (2008) · Cardiovascular Ultrasound · doi:10.1186/1476-7120-6-49 · Cited by 255
Relation of Biomarkers and Cardiac Magnetic Resonance Imaging After Marathon Running
Mousavi, N., Czarnecki, A., Kumar, K., Fallah-Rad, N., Lytwyn, M., Han, S.-Y., Francis, A., Walker, J. R., Kirkpatrick, I. D. C., Neilan, T. G., et al. (2009) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2009.01.294 · Cited by 190
Time domain analysis of the arterial pulse in clinical medicine
O’Rourke, M. F. (2009) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-008-0370-7 · Cited by 79
Metadata
- Authors
- Kitabatake, A., Inoue, M., Asao, M., Masuyama, T., Tanouchi, J., Morita, T., Mishima, M., Uematsu, M., Shimazu, T., Hori, M., & Abe, H.
- Venue
- Circulation
- Published
- 1983-08
- Volume
- 68
- Issue
- 2
- Pages
- 302-309
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1984349156
- Cited by
- 779
- References
- 0
- FWCI
- 21.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.