Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 556

The DOI matches its Crossref record.

Three-dimensional echocardiographic reconstruction of the mitral valve, with implications for the diagnosis of mitral valve prolapse.

Levine, R A, Handschumacher, M D, Sanfilippo, A J, Hagege, A A, Harrigan, P, Marshall, J E, Weyman, A E·1989·Circulation

Abstract

Mitral valve prolapse has been diagnosed by two-dimensional echocardiographic criteria with surprising frequency in the general population, even when preselected normal subjects are examined. In most of these individuals, however, prolapse appears in the apical four-chamber view and is absent in roughly orthogonal long-axis views. Previous studies of in vitro models with nonplanar rings have shown that systolic mitral annular nonplanarity can potentially produce this discrepancy. However, to prove directly that apparent leaflet displacement in a two-dimensional view does not constitute true displacement above the three-dimensional annulus requires reconstruction of the entire mitral valve, including leaflets and annulus. Such reconstruction would also be necessary to explore the complex geometry of the valve and to derive volumetric measures of superior leaflet displacement. A technique was therefore developed and validated in vitro for three-dimensional reconstruction of the entire mitral valve. In this technique, simultaneous real-time acquisition of images and their spatial locations permits reconstruction of a localized structure by minimizing the effects of patient motion and respiration. By applying this method to 15 normal subjects, a coherent mitral valve surface could be reconstructed from intersecting scans. The results confirm mitral annular nonplanarity in systole, with a maximum deviation of 1.4 +/- 0.3 cm from planarity. They directly show that leaflets can appear to ascend above the mitral annulus in the apical four-chamber view, as they did in at least one view in all subjects, without actual leaflet displacement above the entire mitral valve in three dimensions, thereby challenging the diagnosis of prolapse by isolated four-chamber view displacement in otherwise normal individuals. This technique allows us to address a uniquely three-dimensional problem with high resolution and provide new information previously unavailable from the two-dimensional images. This new appreciation should enhance our ability to ask appropriate clinical questions relating mitral valve shape and leaflet displacement to clinical and pathologic consequences.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.80.3.589

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 556

Metadata

Authors
Levine, R. A., Handschumacher, M. D., Sanfilippo, A. J., Hagege, A. A., Harrigan, P., Marshall, J. E., & Weyman, A. E.
Venue
Circulation
Published
1989-09
Volume
80
Issue
3
Pages
589-598
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2049626582
Cited by
556
References
0
FWCI
2.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Three-dimensional echocardiographic reconstruction of the mitral valve, with implications for the diagnosis of mitral valve prolapse. https://app.cochat.ai/papers/10.1161/01.cir.80.3.589
The paper
Levine, R. A., Handschumacher, M. D., Sanfilippo, A. J., Hagege, A. A., Harrigan, P., Marshall, J. E., & Weyman, A. E. (1989). Three-dimensional echocardiographic reconstruction of the mitral valve, with implications for the diagnosis of mitral valve prolapse. Circulation. https://doi.org/10.1161/01.cir.80.3.589

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.