Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 293

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Application of a new phased-array ultrasound imaging catheter in the assessment of vascular dimensions. In vivo comparison to cineangiography.

Open access
Nissen, S E, Grines, C L, Gurley, J C, Sublett, K, Haynie, D, Diaz, C, Booth, D C, DeMaria, A N · 1990 · Circulation

Abstract

Tomographic imaging techniques such as ultrasound can provide important information in the evaluation of vascular anatomy. Recent technical advances have permitted fabrication of a small (1.83 mm), phased-array, intravascular ultrasonic imaging catheter capable of continuous real-time, cross-sectional imaging of blood vessels. We used this imaging catheter to compare intraluminal ultrasound with cineangiography in the measurement of vascular dimensions in animals and to assess the intraobserver and interobserver variability of the technique. Segmental deformation of vessel anatomy was produced by stenoses created with a tissue ligature or by balloon dilation. The mean value for measurements of vessel diameter was 5.6 mm by cineangiography and 5.7 mm by intravascular ultrasound. The correlation between cineangiography and ultrasound was close (r = 0.98). Mean cross-sectional area by angiography was 28.8 mm2 and 29.6 mm2 (r = 0.96) by ultrasound. Percent diameter reduction produced by the stenoses averaged 48.4% by cineangiography and 40.1% by ultrasound, and the two methods correlated closely (r = 0.89). Correlation between cineangiography and ultrasound for vessel diameter and area before balloon dilation was closer (r = 0.92 and 0.88) than after balloon dilation (r = 0.86 and 0.81). This difference reflected an increase in measured vessel eccentricity following balloon dilation. These data demonstrate that intravascular ultrasound is an accurate and reproducible method for measurement of vascular diameter and cross-sectional area in vivo. Intravascular ultrasound is capable of accurately identifying and quantifying segmental deformation of vascular dimensions produced by either stenoses or balloon dilation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.81.2.660

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 293

Metadata

Authors
Nissen, S. E., Grines, C. L., Gurley, J. C., Sublett, K., Haynie, D., Diaz, C., Booth, D. C., & DeMaria, A. N.
Venue
Circulation
Published
1990-02
Volume
81
Issue
2
Pages
660-666
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2073002905
Cited by
293
References
5
FWCI
35.89
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.