Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 410

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Restenosis after balloon angioplasty. A practical proliferative model in porcine coronary arteries.

Schwartz, R S, Murphy, J G, Edwards, W D, Camrud, A R, Vliestra, R E, Holmes, D R · 1990 · Circulation

Abstract

A model of proliferative human restenosis was developed in domestic pigs by using deep injury to the coronary arterial media. Metal wire coils were delivered percutaneously to the coronary arteries of 11 pigs with an oversized, high-pressure (14 atm) balloon and were left in place for times ranging from 28 to 70 days. During placement, the balloon expanded the coils and delivered them securely within the arterial lumen. Light microscopic examination of the vessels confirmed fracture of the internal elastic lamina by the coil. An extensive proliferative response occurred in 10 of the 11 pigs and was associated with a luminal area narrowing of at least 50% in all but one pig. The histopathologic features of the proliferative response were identical to those observed in human cases of restenosis after angioplasty. Immunohistochemical studies confirmed the prominence of smooth muscle cells in the proliferative tissue. A similar response was obtained in two of five porcine coronary arteries in which balloon inflation only was performed, without coil implant. This model is practical and inexpensive and closely mimics the proliferative portion of human restenosis both grossly and microscopically. Thus, it may be useful for understanding human restenosis and for testing therapies aimed at preventing restenosis after balloon angioplasty or other coronary interventional procedures.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.82.6.2190

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

See all 410

Metadata

Authors
Schwartz, R. S., Murphy, J. G., Edwards, W. D., Camrud, A. R., Vliestra, R. E., & Holmes, D. R.
Venue
Circulation
Published
1990-12
Volume
82
Issue
6
Pages
2190-2200
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2083935741
Cited by
410
References
17
FWCI
23.60
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Restenosis after balloon angioplasty. A practical proliferative model in porcine coronary arteries. https://app.cochat.ai/papers/10.1161/01.cir.82.6.2190
The paper
Schwartz, R. S., Murphy, J. G., Edwards, W. D., Camrud, A. R., Vliestra, R. E., & Holmes, D. R. (1990). Restenosis after balloon angioplasty. A practical proliferative model in porcine coronary arteries. Circulation. https://doi.org/10.1161/01.cir.82.6.2190

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.