CoChat

Circadian variation in ischemic threshold. A mechanism underlying the circadian variation in ischemic events.

Open access
Quyyumi, A A, Panza, J A, Diodati, J G, Lakatos, E, Epstein, S E · 1992 · Circulation
Cited by 119

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

BACKGROUND: There is a circadian pattern in the occurrence of cardiac events in patients with coronary artery disease. Whether changes in coronary vascular tone contribute to these phenomena is unknown. We measured the ischemic threshold, defined as either the heart rate or rate-pressure product at 1-mm ST segment depression during treadmill exercise and used it as an index of the lowest coronary vascular resistance; the premise was that when ischemic threshold became lower, coronary vascular resistance was higher, and vice versa. METHODS AND RESULTS: Fifteen patients (group A) with stable coronary artery disease underwent four identical treadmill exercise tests in 24 hours, and ischemic threshold was measured as the heart rate at the onset of 1-mm ST depression. Before each treadmill test, postischemic forearm vascular resistance was measured after 5 minutes of forearm occlusion, using strain-gauge plethysmography. Sixteen additional patients (group B) underwent two treadmill tests at 8 AM and 1 PM, and ischemic threshold was measured as the heart rate-blood pressure product at 1-mm ST depression. A circadian variation was noted: In group A, the heart rate-derived ischemic threshold was lower at 8 AM and 9 PM compared with noon and 5 PM (p less than 0.03). Also, in group B, the rate-pressure product-derived ischemic threshold was 8 +/- 2% lower at 8 AM compared with 1 PM (p = 0.008). A circadian variation parallel to the observed variation in ischemic threshold was also noted in the postischemic forearm blood flow, which was lower in the morning and at night (p less than 0.004). There was a strong correlation between postischemic forearm blood flow and ischemic threshold (p less than 0.0001), such that ischemic threshold was lower at the time of day when postischemic forearm blood flow was lower, and vice versa. CONCLUSIONS: A lower ischemic threshold in the morning suggests that the ischemia-induced coronary vascular resistance is increased at this time, a finding supported by a similar variation in postischemic forearm vascular resistance. Parallel changes in forearm and coronary resistance suggest that generalized (neural or humoral factors) rather than local factors are responsible for the observed circadian changes. Increased coronary tone in the mornings may not only contribute to the higher incidence of transient ischemia but may help trigger acute cardiac events at this time.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.86.1.22

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 119

Metadata

Authors
Quyyumi, A. A., Panza, J. A., Diodati, J. G., Lakatos, E., & Epstein, S. E.
Venue
Circulation
Published
1992-07
Volume
86
Issue
1
Pages
22-28
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2046659863
Cited by
119
References
5
FWCI
7.12
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.