The DOI matches its Crossref record.
Radiofrequency catheter ablation for the treatment of human type 1 atrial flutter. Identification of a critical zone in the reentrant circuit by endocardial mapping techniques.
Abstract
BACKGROUND: Recent studies of human type 1 atrial flutter demonstrated reentry in the right atrium and an area of slow conduction in the low posteroseptal right atrium. Direct-current catheter ablation of this area has been only moderately successful in preventing recurrence. Therefore, we performed endocardial activation mapping and entrainment pace mapping during atrial flutter to determine the critical site for radiofrequency ablation of this arrhythmia. METHODS AND RESULTS: Twelve consecutive patients (seven men and five women; age, 21-73 years) with type 1 atrial flutter (mean cycle length, 253 +/- 39 msec) underwent right atrial endocardial activation and entrainment pace mapping using standard transvenous catheter techniques to localize the atrial flutter reentrant circuit, the area of slow conduction, and the exit site from the area of slow conduction. Upon identifying appropriate sites, radiofrequency energy (16-29 W) was applied via a 4-mm tipped catheter. Activation mapping of atrial flutter revealed a counterclockwise reentrant wave front originating just inferior or posterior to the coronary sinus ostium, proceeding superiorly in the atrial septum to the right atrial free wall, then inferiorly toward the tricuspid annulus and finally medially between the inferior vena cava and the tricuspid annulus, where low-amplitude fragmented electrical activity was noted. Entrainment pace mapping from this area produced an exact P wave match to atrial flutter on 12-lead ECG with a long (greater than 40 msec) stimulus-to-P interval indicating slow conduction, whereas pacing just inferior or posterior to the coronary sinus ostium produced an exact P wave match with a short stimulus-to-P interval (less than 40 msec), presumably identifying the exit site from the area of slow conduction. Radiofrequency energy (one to 14 applications) was effective in terminating and preventing reinduction of atrial flutter in 10 patients. In two patients, atrial flutter was not terminated during radiofrequency energy application but during subsequent pacing attempts. Sites where ablation was successful, located just inferior or posterior to the coronary sinus ostium, were characterized by discrete electrograms with activation times of -20 to -50 msec before P wave onset and exact entrainment pace maps with a stimulus-to-P interval of 20 to 40 msec, consistent with the exit site from the area of slow conduction. Follow-up (mean, 16 +/- 9 weeks; range, 2-31 weeks) revealed recurrence of the original atrial flutter in two patients, one of whom underwent repeat ablation without further recurrence, self-limited infrequent recurrence of a new atrial flutter or atrial fibrillation in three suppressed by beta-blocker or digoxin, and no recurrence in seven. CONCLUSIONS: 1) Radiofrequency energy applied to a critical area in the atrial flutter reentrant circuit, inferior or posterior to the coronary sinus ostium, will terminate and prevent arrhythmia reinduction. 2) Long-term follow-up in a larger series of patients will be required to confirm efficacy of this technique, although short-term results look promising.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Olgin, J. E., Kalman, J. M., Fitzpatrick, A. P., & Lesh, M. D. (1995) · Circulation · doi:10.1161/01.cir.92.7.1839 · Cited by 500
Saoudi, N., Cosío, F., Waldo, A., Chen, S. A., Iesaka, Y., Lesh, M., Saksena, S., Salerno, J., & Schoels, W. (2001) · European Heart Journal · doi:10.1053/euhj.2001.2658 · Cited by 464
Natale, A., Newby, K. H., Pisanó, E., Leonelli, F., Fanelli, R., Potenza, D., Beheiry, S., & Tomassoni, G. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00635-5 · Cited by 414
Incidence and predictors of atrial flutter in the general population
Granada, J., Uribe, W., Chyou, P.-H., Maassen, K., Vierkant, R., Smith, P. N., Hayes, J., Eaker, E., & Vidaillet, H. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00982-7 · Cited by 375
Differential pacing for distinguishing block from persistent conduction through an ablation line
Shah, D., Haïssaguerre, M., Takahashi, A., Jaïs, P., Hocini, M., & Clémenty, J. (2000) · Circulation · doi:10.1161/01.cir.102.13.1517 · Cited by 242
Metadata
- Authors
- Feld, G. K., Fleck, R. P., Chen, P. S., Boyce, K., Bahnson, T. D., Stein, J. B., Calisi, C. M., & Ibarra, M.
- Venue
- Circulation
- Published
- 1992-10
- Volume
- 86
- Issue
- 4
- Pages
- 1233-1240
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2041030896
- Cited by
- 527
- References
- 0
- FWCI
- 19.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Radiofrequency catheter ablation for the treatment of human type 1 atrial flutter. Identification of a critical zone in the reentrant circuit by endocardial mapping techniques. https://app.cochat.ai/papers/10.1161/01.cir.86.4.1233
- The paper
- Feld, G. K., Fleck, R. P., Chen, P. S., Boyce, K., Bahnson, T. D., Stein, J. B., Calisi, C. M., & Ibarra, M. (1992). Radiofrequency catheter ablation for the treatment of human type 1 atrial flutter. Identification of a critical zone in the reentrant circuit by endocardial mapping techniques. Circulation. https://doi.org/10.1161/01.cir.86.4.1233
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.