The DOI matches its Crossref record.
Radiofrequency catheter ablation for the treatment of human type 1 atrial flutter. Identification of a critical zone in the reentrant circuit by endocardial mapping techniques.
Abstract
BACKGROUND: Recent studies of human type 1 atrial flutter demonstrated reentry in the right atrium and an area of slow conduction in the low posteroseptal right atrium. Direct-current catheter ablation of this area has been only moderately successful in preventing recurrence. Therefore, we performed endocardial activation mapping and entrainment pace mapping during atrial flutter to determine the critical site for radiofrequency ablation of this arrhythmia. METHODS AND RESULTS: Twelve consecutive patients (seven men and five women; age, 21-73 years) with type 1 atrial flutter (mean cycle length, 253 +/- 39 msec) underwent right atrial endocardial activation and entrainment pace mapping using standard transvenous catheter techniques to localize the atrial flutter reentrant circuit, the area of slow conduction, and the exit site from the area of slow conduction. Upon identifying appropriate sites, radiofrequency energy (16-29 W) was applied via a 4-mm tipped catheter. Activation mapping of atrial flutter revealed a counterclockwise reentrant wave front originating just inferior or posterior to the coronary sinus ostium, proceeding superiorly in the atrial septum to the right atrial free wall, then inferiorly toward the tricuspid annulus and finally medially between the inferior vena cava and the tricuspid annulus, where low-amplitude fragmented electrical activity was noted. Entrainment pace mapping from this area produced an exact P wave match to atrial flutter on 12-lead ECG with a long (greater than 40 msec) stimulus-to-P interval indicating slow conduction, whereas pacing just inferior or posterior to the coronary sinus ostium produced an exact P wave match with a short stimulus-to-P interval (less than 40 msec), presumably identifying the exit site from the area of slow conduction. Radiofrequency energy (one to 14 applications) was effective in terminating and preventing reinduction of atrial flutter in 10 patients. In two patients, atrial flutter was not terminated during radiofrequency energy application but during subsequent pacing attempts. Sites where ablation was successful, located just inferior or posterior to the coronary sinus ostium, were characterized by discrete electrograms with activation times of -20 to -50 msec before P wave onset and exact entrainment pace maps with a stimulus-to-P interval of 20 to 40 msec, consistent with the exit site from the area of slow conduction. Follow-up (mean, 16 +/- 9 weeks; range, 2-31 weeks) revealed recurrence of the original atrial flutter in two patients, one of whom underwent repeat ablation without further recurrence, self-limited infrequent recurrence of a new atrial flutter or atrial fibrillation in three suppressed by beta-blocker or digoxin, and no recurrence in seven. CONCLUSIONS: 1) Radiofrequency energy applied to a critical area in the atrial flutter reentrant circuit, inferior or posterior to the coronary sinus ostium, will terminate and prevent arrhythmia reinduction. 2) Long-term follow-up in a larger series of patients will be required to confirm efficacy of this technique, although short-term results look promising.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Olgin, J. E., Kalman, J. M., Fitzpatrick, A. P., & Lesh, M. D. (1995) · Circulation · doi:10.1161/01.cir.92.7.1839 · Cited by 500
Saoudi, N., Cosío, F., Waldo, A., Chen, S. A., Iesaka, Y., Lesh, M., Saksena, S., Salerno, J., & Schoels, W. (2001) · European Heart Journal · doi:10.1053/euhj.2001.2658 · Cited by 464
Natale, A., Newby, K. H., Pisanó, E., Leonelli, F., Fanelli, R., Potenza, D., Beheiry, S., & Tomassoni, G. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00635-5 · Cited by 414
Incidence and predictors of atrial flutter in the general population
Granada, J., Uribe, W., Chyou, P.-H., Maassen, K., Vierkant, R., Smith, P. N., Hayes, J., Eaker, E., & Vidaillet, H. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00982-7 · Cited by 375
The 1998 NASPE Prospective Catheter Ablation Registry
SCHEINMAN, M. M., & HUANG, S. (2000) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2000.tb00891.x · Cited by 374
Nakagawa, H., Lazzara, R., Khastgir, T., Beckman, K. J., McClelland, J. H., Imai, S., Pitha, J. V., Becker, A. E., Arruda, M., Gonzalez, M. D., et al. (1996) · Circulation · doi:10.1161/01.cir.94.3.407 · Cited by 363
Kalman, J. M., VanHare, G. F., Olgin, J. E., Saxon, L. A., Stark, S. I., & Lesh, M. D. (1996) · Circulation · doi:10.1161/01.cir.93.3.502 · Cited by 346
Kalman, J. M., Olgin, J. E., Saxon, L. A., Fisher, W. G., Lee, R. J., & Lesh, M. D. (1996) · Circulation · doi:10.1161/01.cir.94.3.398 · Cited by 344
Poty, H., Saoudi, N., Aziz, A. A., Nair, M., & Letac, B. (1995) · Circulation · doi:10.1161/01.cir.92.6.1389 · Cited by 317
Cauchemez, B., Haissaguerre, M., Fischer, B., Thomas, O., Clementy, J., & Coumel, P. (1996) · Circulation · doi:10.1161/01.cir.93.2.284 · Cited by 312
Pérez, F. J., Schubert, C. M., Parvez, B., Pathak, V., Ellenbogen, K. A., & Wood, M. A. (2009) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.109.871665 · Cited by 303
Poty, H., Saoudi, N., Nair, M., Anselme, F., & Letac, B. (1996) · Circulation · doi:10.1161/01.cir.94.12.3204 · Cited by 295
A population-based study of mortality among patients with atrial fibrillation or flutter
Vidaillet, H., Granada, J. F., Chyou, P. O.-H., Maassen, K., Ortiz, M., Pulido, J. N., Sharma, P., Smith, P. N., & Hayes, J. (2002) · The American Journal of Medicine · doi:10.1016/s0002-9343(02)01253-6 · Cited by 289
Guidelines for clinical intracardiac electrophysiological and catheter ablation procedures
Zipes, D. P., Dimarco, J. P., Gillette, P. C., Jackman, W. M., Myerburg, R. J., Rahimtoola, S. H., Ritchie, J. L., Cheitlin, M. D., Garson, A., Gibbons, R. J., et al. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)80037-h · Cited by 282
Radio-Frequency Ablation as Treatment for Cardiac Arrhythmias
Morady, F. (1999) · New England Journal of Medicine · doi:10.1056/nejm199902183400707 · Cited by 281
Novel, Magnetically Guided Catheter for Endocardial Mapping and Radiofrequency Catheter Ablation
Faddis, M. N., Blume, W., Finney, J., Hall, A., Rauch, J., Sell, J., Bae, K. T., Talcott, M., & Lindsay, B. (2002) · Circulation · doi:10.1161/01.cir.0000038704.84304.6f · Cited by 280
Differential pacing for distinguishing block from persistent conduction through an ablation line
Shah, D., Haïssaguerre, M., Takahashi, A., Jaïs, P., Hocini, M., & Clémenty, J. (2000) · Circulation · doi:10.1161/01.cir.102.13.1517 · Cited by 242
Schwartzman, D., Callans, D. J., Gottlieb, C. D., Dillon, S. M., Movsowitz, C., & Marchlinski, F. E. (1996) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(96)00345-2 · Cited by 197
Collins, K. K., Love, B. A., Walsh, E. P., Saul, J. P., Epstein, M. R., & Triedman, J. K. (2000) · The American Journal of Cardiology · doi:10.1016/s0002-9149(00)01132-2 · Cited by 194
Risk of stroke in patients with atrial flutter
Biblo, L. A., Yuan, Z., Quan, K. J., Mackall, J. A., & Rimm, A. A. (2001) · The American Journal of Cardiology · doi:10.1016/s0002-9149(00)01374-6 · Cited by 160
Right Atrial Flutter Due to Lower Loop Reentry: Mechanism and Anatomic Substrates
Cheng, J., Cabeen, W. R., & Scheinman, M. M. (1999) · Circulation · doi:10.1161/01.cir.99.13.1700 · Cited by 152
ELLIS, K., WAZNI, O., MARROUCHE, N., MARTIN, D., GILLINOV, M., McCARTHY, P., SAAD, E. B., BHARGAVA, M., SCHWEIKERT, R., SALIBA, W., et al. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.00885.x · Cited by 134
Resolution of cardiomyopathy after ablation of atrial flutter
Luchsinger, J. A., & Steinberg, J. S. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00183-1 · Cited by 121
Atrial Flutter Mapping and Ablation I: Studying Atrial Flutter Mechanisms by Mapping and Entrainment
COSIO, F. G., ARRIBAS, F., LÓPEZ‐GIL, M., & PALACIOS, J. (1996) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1996.tb03368.x · Cited by 111
Risk of thromboembolism in chronic atrial flutter
Wood, K. A., Eisenberg, S. J., Kalman, J. M., Drew, B. J., Saxon, L. A., Lee, R. J., Lesh, M. D., & Scheinman, M. M. (1997) · The American Journal of Cardiology · doi:10.1016/s0002-9149(97)00044-1 · Cited by 108
Schmieder, S. (2003) · European Heart Journal · doi:10.1016/s0195-668x(02)00846-1 · Cited by 101
Contemporary management of atrial flutter
Wellens, H. J. J. (2002) · Circulation · doi:10.1161/01.cir.0000027683.00417.9a · Cited by 87
Santucci, P. A., Varma, N., Cytron, J., Akar, J. G., Wilber, D. J., Al Chekakie, M. O., & Brysiewicz, N. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.08.010 · Cited by 42
Randomized comparison of two targets in typical atrial flutter ablation
Anselme, F., Klug, D., Scanu, P., Poty, H., Lacroix, D., Kacet, S., Cribier, A., & Saoudi, N. (2000) · The American Journal of Cardiology · doi:10.1016/s0002-9149(00)00760-8 · Cited by 33
Biviano, A., Garan, H., Hickey, K., Whang, W., Dizon, J., & Rosenbaum, M. (2010) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-010-9477-5 · Cited by 25
Radiofrequency Ablation of Atrial Flutter: A Randomized Controlled Trial of Two Anatomic Approaches
Passman, R. S., Kadish, A. H., Dibs, S. R., Engelstein, E. D., & Goldberger, J. J. (2004) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2004.00390.x · Cited by 24
AKTAS, M. K., KHAN, M. N., DI BIASE, L., ELAYI, C., MARTIN, D., SALIBA, W., CUMMINGS, J., SCHWEIKERT, R., & NATALE, A. (2010) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2009.01709.x · Cited by 20
Metadata
- Authors
- Feld, G. K., Fleck, R. P., Chen, P. S., Boyce, K., Bahnson, T. D., Stein, J. B., Calisi, C. M., & Ibarra, M.
- Venue
- Circulation
- Published
- 1992-10
- Volume
- 86
- Issue
- 4
- Pages
- 1233-1240
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2041030896
- Cited by
- 527
- References
- 0
- FWCI
- 19.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.