Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 266

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

Reproducibility and Accuracy of Quantitative Myocardial Blood Flow Assessment with 82Rb PET: Comparison with 13N-Ammonia PET

Open access
El Fakhri, Georges, Kardan, Arash, Sitek, Arkadiusz, Dorbala, Sharmila, Abi-Hatem, Nathalie, Lahoud, Youmna, Fischman, Alan, Coughlan, Martha, Yasuda, Tsunehiro, Di Carli, Marcelo F. · 2009 · Journal of Nuclear Medicine

Abstract

UNLABELLED: (82)Rb cardiac PET allows the assessment of myocardial perfusion with a column generator in clinics that lack a cyclotron. There is evidence that the quantitation of myocardial blood flow (MBF) and coronary flow reserve (CFR) with dynamic (82)Rb PET is feasible. The objectives of this study were to determine the accuracy and reproducibility of MBF estimates from dynamic (82)Rb PET by using our methodology for generalized factor analysis (generalized factor analysis of dynamic sequences [GFADS]) and compartment analysis. METHODS: Reproducibility was evaluated in 22 subjects undergoing dynamic rest and dipyridamole stress (82)Rb PET studies at a 2-wk interval. The inter- and intraobserver variability of MBF quantitation with dynamic (82)Rb PET was assessed with 4 repeated estimations by each of 4 observers. Accuracy was evaluated in 20 subjects undergoing dynamic rest and dipyridamole stress PET studies with (82)Rb and (13)N-ammonia, respectively. The left ventricular and right ventricular blood pool and left ventricular tissue time-activity curves were estimated by GFADS. MBF was estimated by fitting the blood pool and tissue time-activity curves to a 2-compartment kinetic model for (82)Rb and to a 3-compartment model for (13)N-ammonia. CFR was estimated as the ratio of peak MBF to baseline MBF. RESULTS: The reproducibility of the MBF estimates in repeated (82)Rb studies was very good at rest and during peak stress (R(2)= 0.935), as was the reproducibility of the CFR estimates (R(2) = 0.841). The slope of the correlation line was very close to one for the estimation of MBF (0.986) and CFR (0.960) in repeated (82)Rb studies. The intraobserver reliability was less than 3% for the estimation of MBF at rest and during peak stress as well as for the estimation of CFR. The interobserver reliabilities were 0.950 at rest and 0.975 at peak stress. The correlation between myocardial flow estimates obtained at rest and those obtained during peak stress in (82)Rb and (13)N-ammonia studies was very good (R(2) = 0.857). Bland-Altman plots comparing CFR estimated with (82)Rb and CFR estimated with (13)N-ammonia revealed an underestimation of CFR with (82)Rb compared with (13)N-ammonia; the underestimation was within +/-1.96 SD. CONCLUSION: MBF quantitation with GFADS and dynamic (82)Rb PET demonstrated excellent reproducibility as well as intra- and interobserver reliability. The accuracy of the absolute quantitation of MBF with factor and compartment analyses and dynamic (82)Rb PET was very good, compared with that achieved with (13)N-ammonia, for MBF of up to 2.5 mL/g/min.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2967/jnumed.104.007831

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 21 references

Cited by

See all 266

Metadata

Authors
El Fakhri, G., Kardan, A., Sitek, A., Dorbala, S., Abi-Hatem, N., Lahoud, Y., Fischman, A., Coughlan, M., Yasuda, T., & Di Carli, M. F.
Venue
Journal of Nuclear Medicine
Published
2009-06-12
Volume
50
Issue
7
Pages
1062-1071
ISSN
  • 0161-5505 (ISSN-L)
  • 2159-662X
OpenAlex
W2124144555
Cited by
266
References
21
FWCI
14.56
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reproducibility and Accuracy of Quantitative Myocardial Blood Flow Assessment with 82Rb PET: Comparison with 13N-Ammonia PET. https://app.cochat.ai/papers/10.2967/jnumed.104.007831
The paper
El Fakhri, G., Kardan, A., Sitek, A., Dorbala, S., Abi-Hatem, N., Lahoud, Y., Fischman, A., Coughlan, M., Yasuda, T., & Di Carli, M. F. (2009). Reproducibility and Accuracy of Quantitative Myocardial Blood Flow Assessment with 82Rb PET: Comparison with 13N-Ammonia PET. Journal of Nuclear Medicine. https://doi.org/10.2967/jnumed.104.007831

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.