Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 383

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Single-Beat Estimation of End-Systolic Pressure-Volume Relation in Humans: A New Method With the Potential for Noninvasive Application

Senzaki, Hideaki, Chen, Chen-Huan, Kass, David A.·1996·Circulation

Abstract

Background The end-systolic pressure-volume relation (ESPVR) provides a useful measure of contractile function. However, the need to acquire multiple cardiac cycles at varying loads limits its applicability. We therefore developed and tested a novel single-beat estimation method that is based on normalized human time-varying elastance curves [E N (t N )]. Methods and Results Pressure-volume (PV) data were measured by conductance catheter in 87 patients with normal or myopathic hearts. Time-varying elastance curves were generated from 72 PV loops (52 patients) and normalized both by amplitude and time to peak amplitude. The resulting E N (t N ) curves were remarkably consistent despite variations in underlying cardiac disease, contractility, loading, and heart rate, with minimal interloop variance during the first 25% to 35% of contraction. On the basis of this finding and assuming ESPVR linearity and constant volume-intercept, ESPVRs were estimated from one beat with the use of PV data measured at normalized time (t N ) and end systole (t max ) to predict intercept: V o(SB) =[E N (t N )×P(t max )×V(t N )−P(t N )×V(t max )]/[E N (t N )×P(t max )−P(t N )] and slope E max(SB) =P es /[V es −V o(SB) ]. Single-beat estimates were highly correlated with measured ESPVR values obtained by standard multiple-beat analysis (including data from 35 additional patients). E max(SB) accurately reflected acute inotropic change and was influenced little by loading. The new estimation method also predicted measured ESPVRs better than prior techniques and was applicable to noninvasive analysis. Conclusions ESPVRs can be reliably estimated in humans from single cardiac cycles by a new method that has a potential for noninvasive application.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.94.10.2497

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 24 references

Cited by

See all 383

Metadata

Authors
Senzaki, H., Chen, C.-H., & Kass, D. A.
Venue
Circulation
Published
1996-11-15
Volume
94
Issue
10
Pages
2497-2506
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2082258689
Cited by
383
References
24
FWCI
2.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Single-Beat Estimation of End-Systolic Pressure-Volume Relation in Humans: A New Method With the Potential for Noninvasive Application. https://app.cochat.ai/papers/10.1161/01.cir.94.10.2497
The paper
Senzaki, H., Chen, C.-H., & Kass, D. A. (1996). Single-Beat Estimation of End-Systolic Pressure-Volume Relation in Humans: A New Method With the Potential for Noninvasive Application. Circulation. https://doi.org/10.1161/01.cir.94.10.2497

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.