Background The most important factor for improving out-of-hospital ventricular fibrillation survival rates is early defibrillation. This can be achieved if small, lightweight, inexpensive automatic external defibrillators are widely disseminated. Because automatic external defibrillator size and cost are directly affected by defibrillation waveform shape and because of the favorable experience with truncated biphasic waveforms in implantable cardioverter-defibrillators, we compared the efficacy of a truncated biphasic waveform with that of a standard damped sine monophasic waveform for transthoracic defibrillation. Methods and Results The principal goal of this multicenter, prospective, randomized, blinded study was to compare the first-shock transthoracic defibrillation efficacy of a 130-J truncated biphasic waveform with that of a standard 200-J monophasic damped sine wave pulse using anterior thoracic pads in the course of implantable cardioverter-defibrillator testing. Pad-pad ECGs were also examined after transthoracic defibrillation. After the elimination of data for 24 patients who did not meet all protocol criteria, the results from 294 patients were analyzed. The 130-J truncated biphasic pulse and the 200-J damped sine wave monophasic pulse resulted in first-shock efficacy rates of 86% and 86%, respectively ( P =.97). ST-segment levels measured 10 seconds after the shock in 151 patients in sinus rhythm were −0.26±1.58 and −1.86±1.93 mm for the 130- and 200-J shocks, respectively ( P <.0001). Conclusions We found that 130-J biphasic truncated transthoracic shocks defibrillate as well as the 200-J monophasic damped sine wave shocks that are traditionally used in standard transthoracic defibrillators and result in fewer ECG abnormalities after the shock.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A sharper Bonferroni procedure for multiple tests of significance
HOCHBERG, Y. (1988) · Biometrika · doi:10.1093/biomet/75.4.800 · Cited by 4,829
Extension of Multiple Range Tests to Group Means with Unequal Numbers of Replications
Kramer, C. Y. (1956) · Biometrics · doi:10.2307/3001469 · Cited by 3,146
Cardiac Electrophysiology: From Cell to Bedside
(1991) · Annals of Internal Medicine · doi:10.7326/0003-4819-114-12-1069_5 · Cited by 2,385
Cardiac arrest and resuscitation: A tale of 29 cities
Eisenberg, M. S., Horwood, B. T., Cummins, R. O., Reynolds-Haertle, R., & Hearne, T. R. (1990) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(05)81805-0 · Cited by 910
Outcome of CPR in a large metropolitan area — where are the survivors?
Becker, L. B., Ostrander, M. P., Barrett, J. A., & Kondos, G. T. (1991) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(05)81654-3 · Cited by 603
Guidelines for cardiopulmonary resuscitation and emergency cardiac care.
González, E. R. (1987) · PubMed · Cited by 555
Lombardi, G. (1994) · JAMA · doi:10.1001/jama.271.9.678 · Cited by 486
Use of the Automatic External Defibrillator in the Management of Out-of-Hospital Cardiac Arrest
Weaver, W. D., Hill, D., Fahrenbruch, C. E., Copass, M. K., Martin, J. S., Cobb, L. A., & Hallstrom, A. P. (1988) · New England Journal of Medicine · doi:10.1056/nejm198809153191101 · Cited by 477
Survival of out-of-hospital cardiac arrest with early initiation of cardiopulmonary resuscitation
Cummins, R. O., Eisenberg, M. S., Hallstrom, A. P., & Litwin, P. E. (1985) · The American Journal of Emergency Medicine · doi:10.1016/0735-6757(85)90032-4 · Cited by 436
Designs for group sequential tests
Fleming, T. R., Harrington, D. P., & O'Brien, P. C. (1984) · Controlled Clinical Trials · doi:10.1016/s0197-2456(84)80014-8 · Cited by 353
Cited by
Panchal, A. R., Bartos, J. A., Cabañas, J. G., Donnino, M. W., Drennan, I. R., Hirsch, K. G., Kudenchuk, P. J., Kurz, M. C., Lavonas, E. J., Morley, P. T., et al. (2020) · Circulation · doi:10.1161/cir.0000000000000916 · Cited by 2,105
Electroporation: theory and methods, perspectives for drug delivery, gene therapy and research
Gehl, J. (2003) · Acta Physiologica Scandinavica · doi:10.1046/j.1365-201x.2003.01093.x · Cited by 973
Use of Automated External Defibrillators by a U.S. Airline
Page, R. L., Joglar, J. A., Kowal, R. C., Zagrodzky, J. D., Nelson, L. L., Ramaswamy, K., Barbera, S. J., Hamdan, M. H., & McKenas, D. K. (2000) · New England Journal of Medicine · doi:10.1056/nejm200010263431702 · Cited by 632
Eisenberg, M. S., & Mengert, T. J. (2001) · New England Journal of Medicine · doi:10.1056/nejm200104263441707 · Cited by 426
Mittal, S., Ayati, S., Stein, K. M., Schwartzman, D., Cavlovich, D., Tchou, P. J., Markowitz, S. M., Slotwiner, D. J., Scheiner, M. A., & Lerman, B. B. (2000) · Circulation · doi:10.1161/01.cir.101.11.1282 · Cited by 338
Kerber, R. E., Becker, L. B., Bourland, J. D., Cummins, R. O., Hallstrom, A. P., Michos, M. B., Nichol, G., Ornato, J. P., Thies, W. H., White, R. D., et al. (1997) · Circulation · doi:10.1161/01.cir.95.6.1677 · Cited by 323
Improving Survival From Sudden Cardiac Arrest: The Role of the Automated External Defibrillator
Marenco, J. P., Wang, P. J., Link, M. S., Homoud, M. K., & Estes III, N. A. M. (2001) · JAMA · doi:10.1001/jama.285.9.1193 · Cited by 283
Cell membrane electropermeabilization by symmetrical bipolar rectangular pulses
Kotnik, T., Mir, L. M., Flisar, K., Puc, M., & Miklavčič, D. (2001) · Bioelectrochemistry · doi:10.1016/s1567-5394(01)00114-1 · Cited by 159
Metadata
- Authors
- Bardy, G. H., Marchlinski, F. E., Sharma, A. D., Worley, S. J., Luceri, R. M., Yee, R., Halperin, B. D., Fellows, C. L., Ahern, T. S., Chilson, D. A., Packer, D. L., Wilber, D. J., Mattioni, T. A., Reddy, R., Kronmal, R. A., & Lazzara, R.
- Venue
- Circulation
- Published
- 1996-11-15
- Volume
- 94
- Issue
- 10
- Pages
- 2507-2514
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2057616068
- Cited by
- 207
- References
- 32
- FWCI
- 15.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.