Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 270

The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.

Restenosis Rates in Diabetic Patients: A Comparison of Coronary Stenting and Balloon Angioplasty in Native Coronary Vessels

Van Belle, Eric, Bauters, Christophe, Hubert, Edouard, Bodart, Jean-Christophe, Abolmaali, Kaveh, Meurice, Thibaud, McFadden, Eugène P., Lablanche, Jean-Marc, Bertrand, Michel E.·1997·Circulation

Abstract

Background Diabetes is a major risk factor for restenosis after coronary balloon angioplasty. Recent studies have shown that coronary stenting significantly reduces restenosis compared with balloon angioplasty alone. However, limited information is available on the effect of coronary stenting in diabetic patients. Methods and Results We designed this study to analyze the effect of diabetes on restenosis in patients treated with either balloon angioplasty or coronary stenting who were enrolled in a 6-month angiographic follow-up program. Three hundred consecutive patients, 19% of whom were diabetics, who underwent coronary stent implantation during a single-vessel procedure on native coronary vessels and who had 6-month angiographic follow-up constituted the study group (stent group). Three hundred consecutive patients who underwent 6-month angiographic follow-up after single-vessel conventional balloon angioplasty served as control patients (balloon group). Preprocedural, postprocedural, and follow-up angiograms were analyzed with quantitative angiography. In the balloon group, the restenosis rate was almost twofold higher in diabetic than in nondiabetic patients (63% versus 36%; P =.0002) owing to both a greater late loss (0.79±0.70 versus 0.41±0.61 mm, respectively; P <.0001) and a higher rate of late vessel occlusion (14% versus 3%, respectively; P <.001). In the stent group, restenosis rates were similar in diabetics and nondiabetics (25% versus 27%, respectively). Furthermore, in the stent group, late loss (0.77±0.65 versus 0.79±0.57 mm, respectively) and the rate of late vessel occlusion (2% versus 1%, respectively) did not differ significantly between diabetic and nondiabetic patients. Conclusions Although diabetics have increased rates of restenosis and late vessel occlusion after simple balloon angioplasty, they have the same improved outcome with coronary stenting that has been documented in nondiabetic patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.96.5.1454

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 27 references

Cited by

See all 270

Metadata

Authors
Van Belle, E., Bauters, C., Hubert, E., Bodart, J.-C., Abolmaali, K., Meurice, T., McFadden, E. P., Lablanche, J.-M., & Bertrand, M. E.
Venue
Circulation
Published
1997-09-02
Volume
96
Issue
5
Pages
1454-1460
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1982122174
Cited by
270
References
27
FWCI
22.38
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Restenosis Rates in Diabetic Patients: A Comparison of Coronary Stenting and Balloon Angioplasty in Native Coronary Vessels. https://app.cochat.ai/papers/10.1161/01.cir.96.5.1454
The paper
Van Belle, E., Bauters, C., Hubert, E., Bodart, J.-C., Abolmaali, K., Meurice, T., McFadden, E. P., Lablanche, J.-M., & Bertrand, M. E. (1997). Restenosis Rates in Diabetic Patients: A Comparison of Coronary Stenting and Balloon Angioplasty in Native Coronary Vessels. Circulation. https://doi.org/10.1161/01.cir.96.5.1454

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.