The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Restenosis Rates in Diabetic Patients: A Comparison of Coronary Stenting and Balloon Angioplasty in Native Coronary Vessels
Abstract
Background Diabetes is a major risk factor for restenosis after coronary balloon angioplasty. Recent studies have shown that coronary stenting significantly reduces restenosis compared with balloon angioplasty alone. However, limited information is available on the effect of coronary stenting in diabetic patients. Methods and Results We designed this study to analyze the effect of diabetes on restenosis in patients treated with either balloon angioplasty or coronary stenting who were enrolled in a 6-month angiographic follow-up program. Three hundred consecutive patients, 19% of whom were diabetics, who underwent coronary stent implantation during a single-vessel procedure on native coronary vessels and who had 6-month angiographic follow-up constituted the study group (stent group). Three hundred consecutive patients who underwent 6-month angiographic follow-up after single-vessel conventional balloon angioplasty served as control patients (balloon group). Preprocedural, postprocedural, and follow-up angiograms were analyzed with quantitative angiography. In the balloon group, the restenosis rate was almost twofold higher in diabetic than in nondiabetic patients (63% versus 36%; P =.0002) owing to both a greater late loss (0.79±0.70 versus 0.41±0.61 mm, respectively; P <.0001) and a higher rate of late vessel occlusion (14% versus 3%, respectively; P <.001). In the stent group, restenosis rates were similar in diabetics and nondiabetics (25% versus 27%, respectively). Furthermore, in the stent group, late loss (0.77±0.65 versus 0.79±0.57 mm, respectively) and the rate of late vessel occlusion (2% versus 1%, respectively) did not differ significantly between diabetic and nondiabetic patients. Conclusions Although diabetics have increased rates of restenosis and late vessel occlusion after simple balloon angioplasty, they have the same improved outcome with coronary stenting that has been documented in nondiabetic patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Serruys, P. W., de Jaegere, P., Kiemeneij, F., Macaya, C., Rutsch, W., Heyndrickx, G., Emanuelsson, H., Marco, J., Legrand, V., Materne, P., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310801 · Cited by 4,556
Fischman, D. L., Leon, M. B., Baim, D. S., Schatz, R. A., Savage, M. P., Penn, I., Detre, K., Veltri, L., Ricci, D., Nobuyoshi, M., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310802 · Cited by 4,271
The Thrombolysis in Myocardial Infarction (TIMI) Trial: Phase I Findings
The TIMI Study Group* (1985) · New England Journal of Medicine · doi:10.1056/nejm198504043121437 · Cited by 3,188
Schömig, A., Neumann, F.-J., Kastrati, A., Schühlen, H., Blasini, R., Hadamitzky, M., Walter, H., Zitzmann-Roth, E.-M., Richardt, G., Alt, E., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199604253341702 · Cited by 2,028
Comparison of Coronary Bypass Surgery with Angioplasty in Patients with Multivessel Disease
(1996) · New England Journal of Medicine · doi:10.1056/nejm199607253350401 · Cited by 1,531
The Thrombolysis in Myocardial Infarction (TIMI) Trial
(1985) · New England Journal of Medicine · doi:10.1056/nejm198510173131611 · Cited by 1,319
Patterns and Mechanisms of In-Stent Restenosis: A Serial Intravascular Ultrasound Study
Hoffmann, R., Mintz, G. S., Dussaillant, G. R., Popma, J. J., Pichard, A. D., Satler, L. F., Kent, K. M., Griffin, J., & Leon, M. B. (1996) · Circulation · doi:10.1161/01.cir.94.6.1247 · Cited by 1,247
Holmes, D. R., Vlietstra, R. E., Smith, H. C., Vetrovec, G. W., Kent, K. M., Cowley, M. J., Faxon, D. P., Gruentzig, A. R., Kelsey, S. F., Detre, K. M., et al. (1984) · The American Journal of Cardiology · doi:10.1016/0002-9149(84)90752-5 · Cited by 1,113
Guidelines for percutaneous transluminal coronary angioplasty
Ryan, T. J. (1988) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(88)90431-7 · Cited by 1,029
Appointment of New Associate Editor for Circulation
Willerson, J. T. (1996) · Circulation · doi:10.1161/01.cir.94.6.1193 · Cited by 954
Arterial Remodeling After Coronary Angioplasty: A Serial Intravascular Ultrasound Study
Mintz, G. S., Popma, J. J., Pichard, A. D., Kent, K. M., Satler, L. F., Chiu Wong, S., Hong, M. K., Kovach, J. A., & Leon, M. B. (1996) · Circulation · doi:10.1161/01.cir.94.1.35 · Cited by 889
Thromboxane Biosynthesis and Platelet Function in Type II Diabetes Mellitus
Davì, G., Catalano, I., Averna, M., Notarbartolo, A., Strano, A., Ciabattoni, G., & Patrono, C. (1990) · New England Journal of Medicine · doi:10.1056/nejm199006213222503 · Cited by 597
Kip, K. E., Faxon, D. P., Detre, K. M., Yeh, W., Kelsey, S. F., & Currier, J. W. (1996) · Circulation · doi:10.1161/01.cir.94.8.1818 · Cited by 452
Post, M. J., Borst, C., & Kuntz, R. E. (1994) · Circulation · doi:10.1161/01.cir.89.6.2816 · Cited by 409
Potential mechanisms promoting restenosis in diabetic patients
Aronson, D., Bloomgarden, Z., & Rayfield, E. J. (1996) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00496-3 · Cited by 327
Kakuta, T., Currier, J. W., Haudenschild, C. C., Ryan, T. J., & Faxon, D. P. (1994) · Circulation · doi:10.1161/01.cir.89.6.2809 · Cited by 311
Lafont, A., Guzman, L. A., Whitlow, P. L., Goormastic, M., Cornhill, J. F., & Chisolm, G. M. (1995) · Circulation Research · doi:10.1161/01.res.76.6.996 · Cited by 310
Restenosis after Arterial Injury Caused by Coronary Stenting in Patients with Diabetes Mellitus
Carrozza, J. P., Kuntz, R. E., Fishman, R. F., & Baim, D. S. (1993) · Annals of Internal Medicine · doi:10.7326/0003-4819-118-5-199303010-00004 · Cited by 275
Unstable Angina: A Comparison of Angioscopic Findings Between Diabetic and Nondiabetic Patients
Silva, J. A., Escobar, A., Collins, T. J., Ramee, S. R., & White, C. J. (1995) · Circulation · doi:10.1161/01.cir.92.7.1731 · Cited by 230
Can restenosis after coronary angioplasty be predicted from clinical variables?
Weintraub, W. S., Kosinski, A. S., Brown, C. L., & King, S. B. (1993) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(93)90711-9 · Cited by 187
Rensing, B. J. W. M., Hermans, W. R. M., Vos, J., Tijssen, J. G. P., Rutch, W., Danchin, N., Heyndrickx, G. R., Mast, E. G., Wijns, W. C., & Serruys, P. W. J. C. (1993) · Circulation · doi:10.1161/01.cir.88.3.975 · Cited by 163
Factors of the Hemostatic System in Diabetic Patients
Ostermann, H., & van de Loo, J. (1986) · Pathophysiology of Haemostasis and Thrombosis · doi:10.1159/000215317 · Cited by 159
Repeat percutaneous transluminal coronary angioplasty and predictors of recurrent restenosis
Quigley, P. J., Hlatky, M. A., Hinohara, T., Rendall, D. S., Perez, J. A. R., Phillips, H. R., Califf, R. M., & Stack, R. S. (1989) · The American Journal of Cardiology · doi:10.1016/0002-9149(89)90309-3 · Cited by 123
Thrombosis and restenosis after stenting in failed angioplasty: comparison with elective stenting.
Foley, J. B., Brown, R. I. G., & Penn, I. (1994) · American Heart Journal · doi:10.1016/0002-8703(94)90004-3 · Cited by 94
Ellenberg and Rifkin's Diabetes Mellitus: Theory and Practice
Rifkin, H., Porte, D., & Gallon, D. J. (1990) · Medical Entomology and Zoology · Cited by 85
Fein, F. S., & Scheuer, J. (1990) · Cited by 58
Hamon, M., Bauters, C., Amant, C., McFadden, E. P., Helbecque, N., Lablanche, J., Bertrand, M. E., & Amouyel, P. (1995) · Circulation · doi:10.1161/01.cir.92.3.296 · Cited by 53
Self-citation
Cited by
Diabetes and Vascular Disease: Pathophysiology, Clinical Consequences, and Medical Therapy: Part I
Creager, M. A., Lüscher, T. F., of, P. W. T. A., Cosentino, F., & Beckman, J. A. (2003) · Circulation · doi:10.1161/01.cir.0000091257.27563.32 · Cited by 1,650
Diabetes mellitus and the clinical and angiographic outcome after coronary stent placement
Elezi, S., Kastrati, A., Pache, J., Wehinger, A., Hadamitzky, M., Dirschinger, J., Neumann, F.-J., & Schömig, A. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00467-7 · Cited by 495
Abizaid, A., Kornowski, R., Mintz, G. S., Hong, M. K., Abizaid, A. S., Mehran, R., Pichard, A. D., Kent, K. M., Satler, L. F., Wu, H., et al. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00286-1 · Cited by 458
(2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00533-7 · Cited by 443
Abizaid, A., Costa, M. A., Centemero, M., Abizaid, A. S., Legrand, V. M. G., Limet, R. V., Schuler, G., Mohr, F. W., Lindeboom, W., Sousa, A. G. M. R., et al. (2001) · Circulation · doi:10.1161/hc3101.093700 · Cited by 337
Metadata
- Authors
- Van Belle, E., Bauters, C., Hubert, E., Bodart, J.-C., Abolmaali, K., Meurice, T., McFadden, E. P., Lablanche, J.-M., & Bertrand, M. E.
- Venue
- Circulation
- Published
- 1997-09-02
- Volume
- 96
- Issue
- 5
- Pages
- 1454-1460
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1982122174
- Cited by
- 270
- References
- 27
- FWCI
- 22.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.