Atrioventricular Conduction During Long-Term Follow-Up of Patients With Sick Sinus Syndrome
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Background —It has been claimed that patients with sick sinus syndrome have an increased risk of developing AV block, but this has never been assessed prospectively. The aim of the present study was to evaluate in a prospective trial AV conduction during the long-term follow-up of patients with sick sinus syndrome. Methods —Two hundred twenty-five consecutive patients with sick sinus syndrome and intact AV conduction were randomized to undergo single-chamber atrial pacing (110 patients) or single-chamber ventricular pacing (115 patients). Follow-up after 3 months and then yearly included measurement of the PQ interval and, in patients with atrial pacemakers, determination of the atrial stimulus–Q intervals at pacing rates of 100 and 120 bpm. The occurrence of AV block in the atrial group was recorded. During follow-up (mean, 5.5±2.4 years), there was no change in PQ interval in either group and no change in atrial stimulus–Q intervals or Wenckebach block point in the atrial group. Four of 110 patients in the atrial group developed grade 2 to 3 AV block that required upgrading of the pacemaker (0.6% per year). Two of these 4 patients had right bundle-branch block at pacemaker implantation. Conclusions —AV conduction, estimated as PQ interval and atrial stimulus–Q interval at atrial pacing rates of 100 and 120 bpm and the Wenckebach block point, remains stable during long-term follow-up. Thus, treatment with single-chamber atrial pacing is safe and can be recommended to patients with sick sinus syndrome without bundle-branch block.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Andersen, H. R., Nielsen, J. C., Thomsen, P. E. B., Thuesen, L., Mortensen, P. T., Vesterlund, T., & Pedersen, A. K. (1997) · The Lancet · doi:10.1016/s0140-6736(97)03425-9 · Cited by 841 · cited 4×
“In prospective randomized evaluation, single-chamber atrial pacing is superior to single-chamber ventricular pacing in patients with sick sinus syndrome due to lower overall and cardiovascular mortality rates, less atrial fibrillation, less arterial thromboembolism, and less heart failure.(1) Therefore, it has been re…”
BackgroundMethodResultInfluentialSelf-citationSick Sinus Syndrome Treated with Permanent Pacemaker in 109 Patients: A Follow‐Up Study
Breivik, K., Ohm, O., & Segadal, L. (1979) · Acta Medica Scandinavica · doi:10.1111/j.0954-6820.1979.tb13486.x · Cited by 73
Cited by
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.044 · Cited by 1,008
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000628 · Cited by 603
Minimizing Ventricular Pacing to Reduce Atrial Fibrillation in Sinus-Node Disease
Sweeney, M. O., Bank, A. J., Nsah, E., Koullick, M., Zeng, Q. C., Hettrick, D., Sheldon, T., & Lamas, G. A. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa071880 · Cited by 520
Nielsen, J. C., Kristensen, L., Andersen, H. R., Mortensen, P. T., Pedersen, O. L., & Pedersen, A. K. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00757-5 · Cited by 506
Self-citationA New Paradigm for Physiologic Ventricular Pacing
Sweeney, M. O., & Prinzen, F. W. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.09.029 · Cited by 221
Metadata
- Authors
- Andersen, H. R., Nielsen, J. C., Thomsen, P. E. B., Thuesen, L., Vesterlund, T., Pedersen, A. K., & Mortensen, P. T.
- Venue
- Circulation
- Published
- 1998-09-29
- Volume
- 98
- Issue
- 13
- Pages
- 1315-1321
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2025332400
- Cited by
- 124
- References
- 2
- FWCI
- 3.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Atrioventricular Conduction During Long-Term Follow-Up of Patients With Sick Sinus Syndrome. https://app.cochat.ai/papers/10.1161/01.cir.98.13.1315
- The paper
- Andersen, H. R., Nielsen, J. C., Thomsen, P. E. B., Thuesen, L., Vesterlund, T., Pedersen, A. K., & Mortensen, P. T. (1998). Atrioventricular Conduction During Long-Term Follow-Up of Patients With Sick Sinus Syndrome. Circulation. https://doi.org/10.1161/01.cir.98.13.1315
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.