The DOI matches its Crossref record.
Ultrasound Enhances Reporter Gene Expression After Transfection of Vascular Cells In Vitro
Open accessAbstract
Background —Restenosis after percutaneous coronary intervention remains a serious clinical problem. Progress in local gene therapy to prevent restenosis has been hindered by concerns over the safety and efficacy of viral vectors and the limited efficiency of nonviral techniques. This study investigates the use of adjunctive ultrasound to enhance nonviral gene delivery. Methods and Results —Cultured porcine vascular smooth muscle cells (VSMCs) and endothelial cells (ECs) were transfected with naked or liposome-complexed luciferase reporter plasmid for 3 hours. Ultrasound exposure (USE) for 60 seconds at 1 MHz, 0.4 W/cm 2 , 30 minutes into this transfection period enhanced luciferase activity 48 hours later by 7.5-fold and 2.4-fold, respectively. Luciferase activity after lipofection of ECs was similarly enhanced 3.3-fold by adjunctive USE. USE had no effect on cell viability, although it inhibited VSMC but not EC proliferation. Conclusions —Adjunctive USE was associated with enhanced transgene expression in VSMCs and ECs and reduced VSMC but not EC proliferation in vitro, which suggests that ultrasound-assisted local gene therapy has potential as an antirestenotic therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Smart micro/nanoparticles in stimulus-responsive drug/gene delivery systems
Karimi, M., Ghasemi, A., Sahandi Zangabad, P., Rahighi, R., Moosavi Basri, S. M., Mirshekari, H., Amiri, M., Shafaei Pishabad, Z., Aslani, A., Bozorgomid, M., et al. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00798d · Cited by 1,519
Weissleder, R., & Mahmood, U. (2001) · Radiology · doi:10.1148/radiology.219.2.r01ma19316 · Cited by 1,315
Microbubbles in ultrasound-triggered drug and gene delivery
Hernot, S., & Klibanov, A. L. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2008.03.005 · Cited by 990
Therapeutic applications of ultrasound
ter Haar, G. (2007) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2006.07.005 · Cited by 721
Ultrasonic drug delivery – a general review
Pitt, W. G., Husseini, G. A., & Staples, B. J. (2004) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.1.1.37 · Cited by 621
Therapeutic applications of lipid-coated microbubbles
Unger, E. C., Porter, T., Culp, W., Labell, R., Matsunaga, T., & Zutshi, R. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.12.006 · Cited by 591
Intramembrane cavitation as a unifying mechanism for ultrasound-induced bioeffects
Krasovitski, B., Frenkel, V., Shoham, S., & Kimmel, E. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1015771108 · Cited by 550
Micelles and nanoparticles for ultrasonic drug and gene delivery
Husseini, G. A., & Pitt, W. G. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2008.03.008 · Cited by 468
Microbubbles and ultrasound: from diagnosis to therapy
DIJKMANS, P., JUFFERMANS, L., MUSTERS, R., VANWAMEL, A., TENCATE, F., VANGILST, W., VISSER, C., DEJONG, N., & KAMP, O. (2004) · European Journal of Echocardiography · doi:10.1016/j.euje.2004.02.001 · Cited by 420
Coronary in-stent restenosis: Current status and future strategies
Lowe, H. C., Oesterle, S. N., & Khachigian, L. M. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01742-9 · Cited by 414
Ylä-Herttuala, S., & Martin, J. F. (2000) · The Lancet · doi:10.1016/s0140-6736(99)04180-x · Cited by 375
Lan, H. Y., Mu, W., Tomita, N., Huang, X. R., Li, J. H., Zhu, H.-J., Morishita, R., & Johnson, R. J. (2003) · Journal of the American Society of Nephrology · doi:10.1097/01.asn.0000067632.04658.b8 · Cited by 344
Microbubble-enhanced ultrasound for vascular gene delivery
Lawrie, A., Brisken, A., Francis, S., Cumberland, D., Crossman, D., & Newman, C. (2000) · Gene Therapy · doi:10.1038/sj.gt.3301339 · Cited by 343
Self-citationSinn, P. L., Sauter, S. L., & McCray, P. B. (2005) · Gene Therapy · doi:10.1038/sj.gt.3302570 · Cited by 322
Encapsulated ultrasound microbubbles: Therapeutic application in drug/gene delivery
Liu, Y., Miyoshi, H., & Nakamura, M. (2006) · Journal of Controlled Release · doi:10.1016/j.jconrel.2006.05.018 · Cited by 319
Gene therapy for ocular diseases meditated by ultrasound and microbubbles (Review)
WAN, C., LI, F., & LI, H. (2015) · Molecular Medicine Reports · doi:10.3892/mmr.2015.4054 · Cited by 36
“Studies have reported that microbubbles enhanced gene delivery efficiency by lowering the cavitation threshold and enhance cavitation erosion (52), and the ‘spillover space’ on the cell membrane after the microbubble cavitation lasted for 24 h, which is sufficient for gene entry and expression (53).”
Metadata
- Authors
- Lawrie, A., Brisken, A. F., Francis, S. E., Tayler, D. I., Chamberlain, J., Crossman, D. C., Cumberland, D. C., & Newman, C. M.
- Venue
- Circulation
- Published
- 1999-05-25
- Volume
- 99
- Issue
- 20
- Pages
- 2617-2620
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2149492643
- Cited by
- 187
- References
- 0
- FWCI
- 12.26
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.