The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Use of an Extended Monitoring Strategy in Patients With Problematic Syncope
Open accessAbstract
Background —The conventional investigation of patients who present with syncope involves short-term ECG monitoring or provocative testing with head-up tilt and electrophysiological testing. A symptom-rhythm correlation is often difficult to obtain during spontaneous syncope because of its sporadic, infrequent, and unpredictable nature. Methods and Results —We used a prolonged monitoring strategy to determine the cause of syncope in 85 patients (age, 59±18 years; 44 men) with recurrent undiagnosed syncope with an implantable loop recorder capable of cardiac monitoring for up to 18 months. During a mean of 10.5±4.0 months of follow-up, symptoms recurred in 58 patients (68%) 71±79 days (2.3±2.6 months) after implantable loop recorder insertion. An arrhythmia was detected in 42% of patients who recorded a rhythm during recurrent symptoms, with bradycardia present in 18 and tachycardia in 3. Five of the 18 bradycardic patients and 2 additional sinus rhythm patients received a clinical diagnosis of neurally mediated syncope. Patients who experienced presyncope were much less likely to record an arrhythmia during symptoms compared with recurrence of syncope (24% versus 70%, P =0.0005). There were no adverse events associated with recurrent symptoms, and there were no sudden deaths. Inability to freeze after an event occurred in 8 patients, and pocket infection occurred in 3. Conclusions —The strategy of prolonged monitoring is effective and safe in patients with problematic syncope.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“However, the devices have been shown to improve care in only the subset of patients who are older, have asystole documented on the ILR, and whose tilt test results were negative, probably because many of the diagnoses are of vasovagal syncope.”
From 2015 Heart Rhythm Society Expert Consensus Statement on the Diagnosis and Treatment of Postural Tachycardia Syndrome, Inappropriate Sinus Tachycardia, and Vasovagal Syncope (2015) · cites this paper as [106]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“These patients appear to benefit from permanent pacing.105–112”
From 2015 Heart Rhythm Society Expert Consensus Statement on the Diagnosis and Treatment of Postural Tachycardia Syndrome, Inappropriate Sinus Tachycardia, and Vasovagal Syncope (2015) · cites this paper as [106]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“The gold standard for the diagnosis of arrhythmic syncope is when there is a correlation between the symptoms and an ECG recording. 195,196”
From 2018 ESC Guidelines for the diagnosis and management of syncope (2018) · cites this paper as [196]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Prospective Evaluation and Follow-up of Patients with Syncope
Kapoor, W. N., Karpf, M., Wieand, S., Peterson, J. R., & Levey, G. S. (1983) · New England Journal of Medicine · doi:10.1056/nejm198307283090401 · Cited by 779
Evaluation and outcome of emergency room patients with transient loss of consciousness
Day, S. C., Cook, E. F., Funkenstein, H., & Goldman, L. (1982) · The American Journal of Medicine · doi:10.1016/0002-9343(82)90913-5 · Cited by 587
Evaluation and Outcome of Patients with Syncope
KAPOOR, W. N. (1990) · Medicine · doi:10.1097/00005792-199005000-00004 · Cited by 539
Upright tilt testing in evaluating syncope: A comprehensive literature review
Kapoor, W. N., Smith, M. A., & Miller, N. L. (1994) · The American Journal of Medicine · doi:10.1016/0002-9343(94)90051-5 · Cited by 275
Incremental diagnostic yield of loop electrocardiographic recorders in unexplained syncope
Linzer, M., Pritchett, E. L. C., Pontinen, M., McCarthy, E., & Divine, G. W. (1990) · The American Journal of Cardiology · doi:10.1016/0002-9149(90)90591-n · Cited by 239
Prospective evaluation of syncope
Martin, G. J., Adams, S. L., Martin, H. G., Mathews, J., Zull, D., & Scanlon, P. J. (1984) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(84)80511-9 · Cited by 239
Evaluation and Management of the Patient With Syncope
Kapoor, W. N. (1992) · JAMA · doi:10.1001/jama.1992.03490180085031 · Cited by 236
Unexplained Syncope Evaluated by Electrophysiologic Studies and Head-up Tilt Testing
SRA, J. S., Anderson, A. J., Sheikh, S. H., Avitall, B., TCHOU, P. J., Troup, P. J., Gilbert, C. J., Akhtar, M., & Jazayeri, M. R. (1991) · Annals of Internal Medicine · doi:10.7326/0003-4819-114-12-1013 · Cited by 220
The etiology of syncope in patients with negative tilt table and electrophysiological testing
Krahn, A. D., Klein, G. J., Norris, C., & Yee, R. (1995) · Circulation · doi:10.1161/01.cir.92.7.1819 · Cited by 215
Self-citationSyncope: Current Diagnostic Evaluation and Management
Manolis, A. S., Linzer, M., Salem, D. N., & Estes, N. A. M. (1990) · Annals of Internal Medicine · doi:10.7326/0003-4819-112-11-850 · Cited by 209
Flagged first, then by citations
Cited by
Sorted by citations
Items 201–300 of 359
Schernthaner, C., Danmayr, F., Altenberger, J., Pichler, M., & Strohmer, B. (2008) · PubMed · Cited by 6
Recording that elusive rhythm.
Krahn, A. D., Klein, G. J., Yee, R. K., & Skanes, A. C. (1999) · Europe PMC (PubMed Central) · Cited by 6
Self-citationThe implantable loop recorder: a tool that is "here to stay".
de Cock, C. C. (2002) · PubMed · Cited by 4
Howard, J. P., Vasudevan, N., Sarkar, S., Landman, S. R., Koehler, J. L., & Keene, D. (2024) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztae035 · Cited by 5
Ermiş, C., Zhu, A. X., & Pham, S. (2004) · ACC Current Journal Review · doi:10.1016/j.accreview.2003.10.022 · Cited by 5
Experience With Implantable Loop Recorders for Recurrent Unexplained Syncope
Brignole, M. (2008) · Congestive Heart Failure · doi:10.1111/j.1751-7133.2008.tb00014.x · Cited by 4
Point of care technologies for cardiac patients in rural India
Shrivastav, M., Padte, S., Choudhury, M., & Patil, K. (2013) · doi:10.1109/pht.2013.6461312 · Cited by 5
“However, quality of recorded data is poor, patient convenience and comfort is compromised, and subsequently, the diagnostic yield of such devices is low [15].”
BackgroundEvaluating elderly patients with syncope
Sim, V., Pascual, J. F., & Woo, J. (2002) · Archives of Gerontology and Geriatrics · doi:10.1016/s0167-4943(02)00003-1 · Cited by 5
Turley, A. J., Tynan, M., & Plummer, C. (2009) · EP Europace · doi:10.1093/europace/eup193 · Cited by 5
Futterman, L. G., & Lemberg, L. (2002) · The Journal of Cardiovascular Nursing · doi:10.1097/00005082-200204000-00004 · Cited by 5
Heaven, D., & Sutton, R. (2000) · Critical Care Medicine · doi:10.1097/00003246-200010001-00002 · Cited by 5
Brignole, M. (2005) · doi:10.1002/9780470994801.ch7 · Cited by 5
The implantable loop recorder in children: searching for indications
Pass, R. H., & Liberman, L. (2008) · Heart · doi:10.1136/hrt.2007.126276 · Cited by 5
Duvillier, L., Demolder, A., Renterghem, S. V., Mey, C. D., West, F., & Pooter, J. D. (2024) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.16420 · Cited by 5
“5 Conventional diagnostic work ‐ up results in 30% of syncope cases remaining unexplained, 2,6 with an increased risk of recurrence and therefore trauma or fatalities.”
Salih, H., Monsel, F., Sergent, J., & Amara, W. (2012) · Annales de Cardiologie et d Angéiologie · doi:10.1016/j.ancard.2012.08.033 · Cited by 4
Prognosis of Presyncope in Patients With Structural Heart Disease
Reverte, J. G., Lázaro, C. L., Garcı́a-Alberola, A., Zapata, M. G., García, R. G., Sánchez-Muñoz, J.-J., Sánchez, J. M., & Chávarri, M. V. (2004) · Revista Española de Cardiología (English Edition) · doi:10.1016/s1885-5857(06)60286-7 · Cited by 4
Steinberg, C., Bennett, M. T., & Krahn, A. D. (2017) · Cardiovascular medicine · doi:10.1007/978-3-319-58000-5_5 · Cited by 5
Self-citationAkdeniz, C., Özyılmaz, İ., Saygı, M., Ergül, Y., & Tuzcu, V. (2013) · Europe PMC (PubMed Central) · Cited by 4
Abdominal Implantation of Loop Recorders in Infants and Children
Sreeram, N., Hitchcock, F., & Bennink, G. B. W. E. (2005) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2003.11.019 · Cited by 4
Kürer, C. C. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00660-0 · Cited by 4
Holding Area LINQ Trial (HALT)
Lee, J. J., Weitz, D. S., & Anand, R. G. (2017) · Indian Pacing and Electrophysiology Journal · doi:10.1016/j.ipej.2017.06.003 · Cited by 4
Audet, S. A., Carney, J., Haubrich, G., Rubén, D. T.-S., Herrmann, E., Larik, V. C. M. H., Receveur, R. A. M., Scott, E. R., & Vaughn, G. (2008) · Elsevier eBooks · doi:10.1016/b978-044452190-3.00068-9 · Cited by 4
Bradykarde Rhythmusstörungen in der Intensivmedizin
Trappe, H. (2006) · Steinkopff eBooks · doi:10.1007/3-7985-1630-8_32 · Cited by 4
Bolz, A., & Urbaszek, W. (2002) · Springer eBooks · doi:10.1007/978-3-642-56230-3_5 · Cited by 4
Electrocardiographic Monitoring Strategies (Holter, Implantable Loop Recorder, in Between)
Nazzari, H., Halperin, L. F., & Krahn, A. D. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-809657-4.99770-9 · Cited by 3
Self-citationTest d'inclinaison : modalités, techniques et résultats
Kouakam, C. (2011) · EMC - Cardiologie · doi:10.1016/s1166-4568(11)43685-8 · Cited by 4
“[10] Krahn AD, Klein GJ, Yee R, Takle-Neuhouse T, Norris C, Reveal Investigators.”
« Malaise », lipothymie et syncope
Lestavel, P., & Marquié, C. (2004) · EMC - Médecine · doi:10.1016/j.emcmed.2004.03.002 · Cited by 3
Experiencia clínica con el uso del monitor cardiaco implantable
Vanegas, D. I., Jiménez, N. J., Rincón, C. A., Hernández, M. A., & Valderrama-Barbosa, Z. (2016) · Revista Colombiana de Cardiología · doi:10.1016/j.rccar.2016.08.004 · Cited by 3
Implantable Cardiac Rhythm and Hemodynamic Monitors
Daly, M. G., Melton, I., & Crozier, I. (2016) · Elsevier eBooks · doi:10.1016/b978-0-323-37804-8.00025-0 · Cited by 3
Subbiah, R. N., Gula, L. J., Klein, G. J., Skanes, A. C., Yee, R. K., & Krahn, A. D. (2008) · Springer eBooks · doi:10.1007/978-1-84628-854-8_23 · Cited by 3
Self-citationADVANCES IN CARDIAC ELECTROPHYSIOLOGY AND PACING
Lü, F., & Trohman, R. G. (2001) · Critical Care Clinics · doi:10.1016/s0749-0704(05)70171-8 · Cited by 3
The role of the implantable loop recorder in the investigation of recurrent syncope.
Sideris, S. K., Mousiama, T. A., Stougiannos, P. N., Skiadas, I., Laiou, F. P., Sotiropoulos, I., Gatzoulis, K. A., Stefanadis, C., & Kallikazaros, I. E. (2009) · PubMed · Cited by 3
Episodic Impairment of Consciousness
Bruni, J. (2008) · Elsevier eBooks · doi:10.1016/b978-0-7506-7525-3.50004-2 · Cited by 3
Syncope and Arrhythmias: Role of the Electrophysiological Study
Stouffer, G. A., Sheahan, R. G., Lenihan, D. J., & Sheahan, R. G. (2001) · The American Journal of the Medical Sciences · doi:10.1097/00000441-200107000-00007 · Cited by 3
Lasam, G. U., Dudhia, J., Anghel, S., & Brensilver, J. M. (2018) · Cardiology Research · doi:10.14740/cr751w · Cited by 3
Current investigations used to assess syncope
Arthur, W., & Kaye, G. (2001) · Postgraduate Medical Journal · doi:10.1136/pmj.77.903.20 · Cited by 3
Bradycardia risk stratification with implantable loop recorder after unexplained syncope
Ciancio, G. D., Sadoul, N., Hammache, N., Pace, N., Echivard, M., Freysz, L., Blangy, H., Sellal, J., & Olivier, A. (2024) · Archives of cardiovascular diseases · doi:10.1016/j.acvd.2023.12.007 · Cited by 3
Discovering the cause of syncope
Hauer, K. E. (2003) · Postgraduate Medicine · doi:10.3810/pgm.2003.01.1356 · Cited by 2
Syncope/Presyncope in the Competitive Athlete
Asplund, C. A., O’Connor, F. G., & Levine, B. D. (2010) · Springer eBooks · doi:10.1007/978-0-387-92775-6_9 · Cited by 2
“Among the 85 patients studied, 18 with bradycardia and 3 with tachycardia were identified when symptoms recurred at a mean of 2.3 months after implantation [ 32 ].”
BackgroundMethodInfluentialAmara, W., Sileu, N., Salih, H., Sergent, J., & Monsel, F. (2014) · Annales de Cardiologie et d Angéiologie · doi:10.1016/j.ancard.2014.08.007 · Cited by 2
Maintien à; domicile des personnes âgées
Magnier, A. (2006) · EMC - Traité de médecine AKOS · doi:10.1016/s1634-6939(06)75290-5 · Cited by 2
Kanjwal, M. Y., & Grubb, B. P. (2005) · Current Cardiology Reports · doi:10.1007/s11886-005-0085-4 · Cited by 2
Syncope in Patients with Organic Heart Disease
Olshansky, B., & Sullivan, R. M. (2013) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2013.08.006 · Cited by 2
Differences in the yield of the implantable loop recorder between secondary and tertiary centers
Lacunza, J., Moya‐Mitjans, À., Martínez-Alday, J. D., Barón‐Esquivias, G., Ruiz‐Granell, R., Rivas‐Gándara, N., González‐Enríquez, S., Leal-del-Ojo, J., García-Heil, N., & Garcı́a-Alberola, A. (2015) · Cardiology Journal · doi:10.5603/cj.a2014.0088 · Cited by 2
Franke, J., Zugck, C., & Katus, H. A. (2013) · Der Kardiologe · doi:10.1007/s12181-013-0514-3 · Cited by 2
Externe und implantierbare Ereignisrekorder zum Event-Recording in der Synkopendiagnostik
Seidl, K., Vater, M., & Senges, J. (2002) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-002-0340-y · Cited by 2
Novel use of an “insertable” loop recorder
Gimbel, J. (2003) · Heart · doi:10.1136/heart.89.6.e18 · Cited by 2
“While direct patient activation of the insertable loop recorder (ILR) through a small hand held pager-like device (Activator) is the primary means to capture a symptomatic arrhythmic event, the Reveal Plus can automatically detect significant bradycardic and tachycardic events to supplement patient activation. Despite…”
BackgroundKajdič, N., Mežnar, A. Z., Šinkovec, M., & Žižek, D. (2020) · Minerva Cardiology and Angiology · doi:10.23736/s0026-4725.20.05247-0 · Cited by 3
Implantable diagnostic and therapeutic devices in children.
Tn, L., Gouw, S. C., Hoorntje, T. M., & Sreeram, N. (2002) · PubMed Central · Cited by 2
Benditt, D. G., & Sutton, R. (2005) · Wiley eBooks · doi:10.1002/9780470994801.ch4 · Cited by 2
Peinado, R., & Merino, J. L. (2001) · Revista Española de Cardiología · doi:10.1016/s0300-8932(01)76327-0 · Cited by 2
Koller, M. L., & Meesmann, M. (2000) · Zeitschrift für Kardiologie · doi:10.1007/s003920070156 · Cited by 2
“Die Strategieeinesprolongierten EKG-Monitorings bei Patientenmit rezidivierendenSynkopenunklarerGenese hat sich nachden ErgebnisseneineraktuellenStudie (8) als effektiv und sichererwiesen.”
BackgroundMitjans, À. M. (2000) · Springer eBooks · doi:10.1007/978-88-470-2139-6_59 · Cited by 2
Seegers, J., & Zabel, M. (2011) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-011-0131-4 · Cited by 1
The Evolving Role of Insertable Cardiac Monitors in Patients with Congenital Heart Disease
Beach, C. M., Richardson, C., & Paul, T. (2023) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2023.06.001 · Cited by 1
Calkins, H. G. (2004) · Elsevier eBooks · doi:10.1016/b0-7216-0323-8/50099-3 · Cited by 1
Clinical Factors Affecting Symptom Recurrence in Patients with Syncope
Lee, S. H., Kim, B. J., Park, S., On, Y. K., Huh, J., & Kim, B. J. (2014) · Cardiology · doi:10.1159/000366267 · Cited by 1
Implantable Loop Recorder in Clinical Practice
Babuty, D., Pierre, B., Clémenty, N., Lallemand, B., Marie, O., & Fauchier, L. (2011) · InTech eBooks · doi:10.5772/21350 · Cited by 1
“(Krahn et al., 1999a, 2001a). www.intechopen.com The International Study on Syncope of Uncertain Etiology (ISSUE) proposed a classification of spontaneous syncope documented by an implantable loop recorder (Brignole et al., 2005b) dependent on the mechanism of syncope (Table 3).”
BackgroundSíncope reflexa vasovagal – haverá benefício da terapêutica com pacemaker?
Sousa, P. A., Candeias, R., Marques, N. S., & de Jesus, I. (2014) · Revista Portuguesa de Cardiologia · doi:10.1016/j.repc.2014.02.007 · Cited by 1
Atrioventricular block and problems with atrioventricular conduction
Bourke, J. P. (2002) · Clinics in Geriatric Medicine · doi:10.1016/s0749-0690(02)00007-1 · Cited by 1
Patientenaktivierte EKD-Aufzeichnung bei Kindern
Hennig, B., Heinke, F., Kinzel, P., Kottkamp, H., Schneider, P., & Häusler, H.-J. (2000) · Monatsschrift Kinderheilkunde · doi:10.1007/s001120050650 · Cited by 1
Reflex vasovagal syncope – Is there a benefit in pacemaker therapy?
Sousa, P. A., Candeias, R., Marques, N. S., & de Jesus, I. (2014) · Revista Portuguesa de Cardiologia (English Edition) · doi:10.1016/j.repce.2014.05.001 · Cited by 1
Value of Ambulatory Electrocardiographic Monitoring in Syncope
Giada, F., & Bartoletti, A. (2013) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2013.08.009 · Cited by 1
« Malaise », lipothymie et syncope
Lestavel, P., & Marquié, C. (2006) · EMC - Médecine d urgence · doi:10.1016/s1959-5182(06)73437-7 · Cited by 1
Early Results of the Modified Right Atrial Lesion Set for the Cox-Cryomaze Procedure
Cheema, F. H., Younus, M. A., Siddiqui, O., Younus, M. J., Mahmood, M. A., Pervez, M. B., & Roberts, H. G. (2016) · Innovations Technology and Techniques in Cardiothoracic and Vascular Surgery · doi:10.1097/imi.0000000000000311 · Cited by 1
Predictors of future arrhythmic events in patients with unexplained syncope
Prochnau, D., Lambert, T., Sigusch, H. H., Surber, R., & Schulze, P. C. (2017) · Acta cardiologica. Supplementum · doi:10.1080/00015385.2017.1306389 · Cited by 1
OBSOLETE: Electrocardiographic Monitoring Strategies (Holter, Implantable Loop Recorder, in Between)
Krahn, A. D. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-801238-3.99770-8 · Cited by 1
Self-citationSchuchert, A. (2008) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-008-0011-8 · Cited by 1
Good, E. D., & Jongnarangsin, K. (2020) · Springer eBooks · doi:10.1007/978-3-030-28328-5_17 · Cited by 1
Jain, S., & Chafekar, N. D. (2021) · MVP Journal of Medical Sciences · doi:10.18311/mvpjms/2021/v8i1/278 · Cited by 1
Takahashi, T., Aoki, K., Sato, E., Yamashina, Y., Ishida, A., & Yagi, T. (2023) · HeartRhythm Case Reports · doi:10.1016/j.hrcr.2023.09.001 · Cited by 1
“4 It has also been reported that most fi rst syncope re-currences occur more than 30 days after the implantation of an ICM and that long-term monitoring is necessary to obtain those diagnoses.”
BackgroundSarkar, S., Koehler, J. L., & Vasudevan, N. (2024) · Diagnostics · doi:10.3390/diagnostics14070771 · Cited by 1
“Alongside providing the ability for diagnosis and monitoring of cardiac arrhythmia [17–23], current ICM devices also monitor diagnostic parameters and store aggregated daily measurements longitudinally over a long period of time.”
BackgroundLong-term Monitoring to Detect Risk of Sudden Cardiac Death in Inherited Arrhythmia Patients
Domain, G., Steinberg, C., Davies, B., Strubé, C., Roberts, J. D., Simpson, C., & Krahn, A. D. (2024) · CJC Open · doi:10.1016/j.cjco.2024.05.007 · Cited by 1
Self-citationAhmed, M., Morris, J., & Bommireddi, S. M. (2025) · Cureus · doi:10.7759/cureus.92580 · Cited by 1
“Randomised data (FRESH study) demonstrates that early ILR implantation outperforms conventional pathways of investigating syncope, with higher yield and lower healthcare costs, supporting guideline recommendations of earlier ILR implantation in selected unexplained syncopal patients [12-14].”
Chen, L. Y., & Benditt, D. G. (2010) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2010.01881.x · Cited by 1
2018 KHRS Guidelines for Catheter Ablation of Ventricular Arrhythmias – Part1
Roh, S., Kim, S., Kim, Y.-N., Kim, J.-Y., Kim, J., Kim, T., Nam, G., Park, K., Park, H., Pak, H., et al. (2018) · International Journal of Arrhythmia · doi:10.18501/arrhythmia.2018.006 · Cited by 1
Implantable cardiac monitors: State of the art
Jamal, S. M., Prasad, R. M., Vipparla, N. S., Srivastava, S., Baloch, Z. Q., Banga, E., & Ip, J. H. (2021) · Interventional Cardiology · Cited by 1
New Trends in Evaluation and Management of Syncope
Luria, D. M., & Shen, W.-K. (2000) · Cardiac Electrophysiology Review · doi:10.1023/a:1009907723411 · Cited by 1
Daoulah, A., Calton, R. K., Newman, D. M., Lashevsky, I., & Crystal, E. (2010) · Geriatrics and gerontology international/Geriatrics & gerontology international · doi:10.1111/j.1447-0594.2010.00646.x · Cited by 1
Eltahawy, E. A., & Grubb, B. P. (2007) · Springer eBooks · doi:10.1007/978-0-387-72763-9_13 · Cited by 1
“One hundred and three patients had a documented episode and entered Phase II: 53 patients received specific therapy ( 46 ) a pacemaker because of asystole of a median 11.5 s duration and six anti-tachyarrhythmia therapy (catheter ablation: four, implantable defibrillator: one, anti-arrhythmic drug: one)] and the remai…”
BackgroundInfluentialFragakis, N., Papanastasiou, S., Sidopoulos, E., & Katsaris, G. (2006) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2006.00321.x · Cited by 1
Mittal, S., & Lerman, B. B. (2002) · Humana Press eBooks · doi:10.1007/978-1-59259-094-0_17 · Cited by 1
Kapoor, W. N. (2006) · Springer eBooks · doi:10.1007/0-387-22621-4_65 · Cited by 1
The Use of Implantable Loop Recorders
Krahn, A. D., Klein, G. J., Skanes, A. C., & Yee, R. K. (2004) · Elsevier eBooks · doi:10.1016/b0-7216-0323-8/50088-9
Self-citationDiagnostik der Herzrhythmusstörungen
Steinbeck, G., Hoffmann, E., Reithmann, C., Dorwarth, U., Näbauer, M., STEINBIGLER, P., REMP, T., Gerth, A., & Haberl, R. L. (2000) · Springer eBooks · doi:10.1007/978-3-662-12156-6_22
Hust, M. H., & Dickhuth, H. (2008) · Steinkopff eBooks · doi:10.1007/978-3-7985-1707-3_14
Evaluation and Management of Syncope
Bindra, P. S., Marchlinski, F. E., & Lin, D. (2008) · Clinical Medicine Insights Circulatory Respiratory and Pulmonary Medicine · doi:10.4137/ccrpm.s490
Long Time Monitoring of Cardiac Rhythm in Patients With Atrial Fibrillation
Kesek, M., & Rosenqvist, M. (2004) · doi:10.1002/9780470987483.ch56
The Implantable Loop Recorder for Diagnosis of Unexplained Syncope
Krahn, A. D., Klein, G. J., Skanes, A. C., & Yee, R. K. (2005) · doi:10.1002/9780470994801.ch19
Self-citationEffiziente Synkopenabklärung: Wann soll der implantierbare Loop-Rekorder verwendet werden?
Pezawas, T., & Schmidinger, H. (2004) · Journal für Kardiologie (Krause & Pachernegg GmbH)
Expósito, V., Rodríguez‐Entem, F., González‐Enríquez, S., Ruiz‐Guerrero, L., Toranzo, I., Arnáez, B., Gómez-Delgado, J. M., & Olalla, J. J. (2015) · Cardiocore · doi:10.1016/j.carcor.2015.09.001
Síncope recurrente por bloqueo auriculoventricular paroxístico tardío tras operación de Senning
Bartolomé, F. B. (2001) · Revista Española de Cardiología · doi:10.1016/s0300-8932(01)76370-1
Stellenwert des implantierbaren Looprekorders im Rahmen der Diagnostik von Synkopen
Ehlers, C., Brüggemann, T., Wiedemann, M., & Andresen, D. (2000) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s003990070006
Schuchert, A., Behrens, G., & Meinertz, T. (2000) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/bf03042533
Infrequent Syncope in a Heavy Vehicle Driver
Chua, R., & Thomas, S. P. (2005) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2005.40040.x
Görenek, B., Kudaiberdieva, G., Çavuşoğlu, Y., Göktekín, Ö., Ata, N., Ünalır, A., Birdane, A., & Timuralp, B. (2001) · Angiology · doi:10.1177/000331970105201108
Sadri, H., & Winsor, P. (2014) · Healthcare Management Forum · doi:10.1016/j.hcmf.2014.03.005
The Effect of Late Adoption of Canadian Innovations: A Case for Implantable Cardiac Monitors
Sadri, H., & Winsor, P. (2014) · Healthcare Management Forum · doi:10.1016/j.hcmf.2014.01.002 · Cited by 1
“In direct comparison with alternative tests, ICM is more efficacious than a multiple test strategy (47% yield ICM vs 20% yield ELR, tilt table test and EP study).(29) In addition, when patients crossed over to ICM monitoring after failing on their multiple testing strategy, ICM was diagnostic in a further 38% of cases.”
Síncope en el paciente de edad avanzada
Puisieux, F. L. (2006) · EMC - Tratado de Medicina · doi:10.1016/s1636-5410(06)70382-8
Metadata
- Authors
- Krahn, A. D., Klein, G. J., Yee, R., Takle-Newhouse, T., & Norris, C.
- Affiliations
- Western University (CA)
- From the Division of Cardiology, University of Western Ontario, London, Ontario, Canada, and Medtronic, Minneapolis, Minn (T.T.-N.).
- Venue
- Circulation
- Published
- 1999-01-26
- Volume
- 99
- Issue
- 3
- Pages
- 406-410
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2006949147
- Semantic Scholar
- 23b308c400504de7e0f85483f49bf75ca93e86b0
- Cited by
- 360
- References
- 27
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 10 · 2023: 5 · 2022: 3 · 2021: 7 · 2020: 5 · 2019: 6 · 2018: 12 · 2017: 22 · 2016: 12 · 2015: 13 · 2014: 13 · 2013: 17 · 2012: 9
- FWCI
- 24.90
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Circulation (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Heart and Stroke Foundation of Canada
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Syncope and Autonomic Disorders
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- syncope, implantable loop recorder, prolonged cardiac monitoring, arrhythmia detection, neurally mediated syncope, bradycardia, tachycardia, presyncope, recurrent syncope
- MeSH terms
- Adult, Aged, Arrhythmias, Cardiac, Female, Humans, Male, Middle Aged, Recurrence, Syncope, Electrocardiography, Ambulatory, Tilt-Table Test, Prostheses and Implants
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review