The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Use of an Extended Monitoring Strategy in Patients With Problematic Syncope
Open accessAbstract
Background —The conventional investigation of patients who present with syncope involves short-term ECG monitoring or provocative testing with head-up tilt and electrophysiological testing. A symptom-rhythm correlation is often difficult to obtain during spontaneous syncope because of its sporadic, infrequent, and unpredictable nature. Methods and Results —We used a prolonged monitoring strategy to determine the cause of syncope in 85 patients (age, 59±18 years; 44 men) with recurrent undiagnosed syncope with an implantable loop recorder capable of cardiac monitoring for up to 18 months. During a mean of 10.5±4.0 months of follow-up, symptoms recurred in 58 patients (68%) 71±79 days (2.3±2.6 months) after implantable loop recorder insertion. An arrhythmia was detected in 42% of patients who recorded a rhythm during recurrent symptoms, with bradycardia present in 18 and tachycardia in 3. Five of the 18 bradycardic patients and 2 additional sinus rhythm patients received a clinical diagnosis of neurally mediated syncope. Patients who experienced presyncope were much less likely to record an arrhythmia during symptoms compared with recurrence of syncope (24% versus 70%, P =0.0005). There were no adverse events associated with recurrent symptoms, and there were no sudden deaths. Inability to freeze after an event occurred in 8 patients, and pocket infection occurred in 3. Conclusions —The strategy of prolonged monitoring is effective and safe in patients with problematic syncope.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“However, the devices have been shown to improve care in only the subset of patients who are older, have asystole documented on the ILR, and whose tilt test results were negative, probably because many of the diagnoses are of vasovagal syncope.”
From 2015 Heart Rhythm Society Expert Consensus Statement on the Diagnosis and Treatment of Postural Tachycardia Syndrome, Inappropriate Sinus Tachycardia, and Vasovagal Syncope (2015) · cites this paper as [106]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“These patients appear to benefit from permanent pacing.105–112”
From 2015 Heart Rhythm Society Expert Consensus Statement on the Diagnosis and Treatment of Postural Tachycardia Syndrome, Inappropriate Sinus Tachycardia, and Vasovagal Syncope (2015) · cites this paper as [106]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“The gold standard for the diagnosis of arrhythmic syncope is when there is a correlation between the symptoms and an ECG recording. 195,196”
From 2018 ESC Guidelines for the diagnosis and management of syncope (2018) · cites this paper as [196]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Prospective Evaluation and Follow-up of Patients with Syncope
Kapoor, W. N., Karpf, M., Wieand, S., Peterson, J. R., & Levey, G. S. (1983) · New England Journal of Medicine · doi:10.1056/nejm198307283090401 · Cited by 779
Evaluation and outcome of emergency room patients with transient loss of consciousness
Day, S. C., Cook, E. F., Funkenstein, H., & Goldman, L. (1982) · The American Journal of Medicine · doi:10.1016/0002-9343(82)90913-5 · Cited by 587
Evaluation and Outcome of Patients with Syncope
KAPOOR, W. N. (1990) · Medicine · doi:10.1097/00005792-199005000-00004 · Cited by 539
Upright tilt testing in evaluating syncope: A comprehensive literature review
Kapoor, W. N., Smith, M. A., & Miller, N. L. (1994) · The American Journal of Medicine · doi:10.1016/0002-9343(94)90051-5 · Cited by 275
Incremental diagnostic yield of loop electrocardiographic recorders in unexplained syncope
Linzer, M., Pritchett, E. L. C., Pontinen, M., McCarthy, E., & Divine, G. W. (1990) · The American Journal of Cardiology · doi:10.1016/0002-9149(90)90591-n · Cited by 239
Prospective evaluation of syncope
Martin, G. J., Adams, S. L., Martin, H. G., Mathews, J., Zull, D., & Scanlon, P. J. (1984) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(84)80511-9 · Cited by 239
Evaluation and Management of the Patient With Syncope
Kapoor, W. N. (1992) · JAMA · doi:10.1001/jama.1992.03490180085031 · Cited by 236
Unexplained Syncope Evaluated by Electrophysiologic Studies and Head-up Tilt Testing
SRA, J. S., Anderson, A. J., Sheikh, S. H., Avitall, B., TCHOU, P. J., Troup, P. J., Gilbert, C. J., Akhtar, M., & Jazayeri, M. R. (1991) · Annals of Internal Medicine · doi:10.7326/0003-4819-114-12-1013 · Cited by 220
The etiology of syncope in patients with negative tilt table and electrophysiological testing
Krahn, A. D., Klein, G. J., Norris, C., & Yee, R. (1995) · Circulation · doi:10.1161/01.cir.92.7.1819 · Cited by 215
Self-citationSyncope: Current Diagnostic Evaluation and Management
Manolis, A. S., Linzer, M., Salem, D. N., & Estes, N. A. M. (1990) · Annals of Internal Medicine · doi:10.7326/0003-4819-112-11-850 · Cited by 209
Flagged first, then by citations
Cited by
Sorted by citations
Items 101–200 of 359
Scrocco, C., Ben‐Haim, Y., Devine, B., Tome, M., Papadakis, M., Sharma, S., Macfarlane, P. W., & Behr, E. R. (2021) · Heart Rhythm · doi:10.1016/j.hrthm.2021.08.034 · Cited by 29
Use of an implantable loop recorder in the evaluation of children with congenital heart disease
Sanatani, S., Peirone, A., Chiu, C., Human, D. G., Gross, G. J., & Hamilton, R. M. (2002) · American Heart Journal · doi:10.1067/mhj.2002.120157 · Cited by 29
Reed, M. J., Grubb, N. R., Lang, C. C., Gray, A. J., Simpson, K., MacRaild, A., & Weir, C. J. (2018) · Emergency Medicine Journal · doi:10.1136/emermed-2018-207570 · Cited by 28
A nurse‐led implantable loop recorder service is safe and cost effective
Lim, W. Y., Παπαγεωργίου, Ν., Sukumar, S., Alexiou, S., Srinivasan, N. T., Monkhouse, C. A., Daw, H., Caldeira, H., Harvie, H., Kuriakose, J., et al. (2019) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.14206 · Cited by 28
Gámiz, J. L. P., Jiménez, A., González‐Juanatey, J. R., Huerta, E. M., & Martín-Ambrosio, E. S. (2000) · Revista Española de Cardiología · doi:10.1016/s0300-8932(00)75066-4 · Cited by 28
Utility of patient-activated cardiac event recorders in the detection of cardiac arrhythmias
Wu, C.-C., Hsieh, M.-H., Tai, C.-T., Chiang, C.-E., Yu, W.-C., Lin, Y.-K., Tsao, H.-M., Ding, P. Y.-A., & Chen, S.-A. (2003) · Journal of Interventional Cardiac Electrophysiology · doi:10.1023/a:1023604816368 · Cited by 27
An Anatomic-Based Approach for the Placement of Implantable Loop Recorders
Grubb, B. P., Welch, M., Kanjwal, K., Karabin, B. L., & Kanjwal, Y. (2010) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2010.02747.x · Cited by 27
Management of vasovagal syncope: 2004
Sheldon, R. S., Morillo, C. A., & Krahn, A. D. (2004) · Expert Review of Cardiovascular Therapy · doi:10.1586/14779072.2.6.915 · Cited by 26
Self-citationUtility of implantable loop recorders for diagnosing unexplained syncope in clinical practice
Entem, F. R., Enríquez, S. G., Cobo, M., Expósito, V., Llano, M., Ruiz, M., Olalla, J. J., & Fernández, M. O. (2009) · Clinical Cardiology · doi:10.1002/clc.20342 · Cited by 25
The use of monitoring strategies in patients with unexplained syncope
Krahn, A. D., Klein, G. J., Yee, R. K., & Skanes, A. C. (2004) · Clinical Autonomic Research · doi:10.1007/s10286-004-1008-y · Cited by 25
Self-citationLawless, C. E., & Briner, W. W. (2008) · Sports Medicine · doi:10.2165/00007256-200838080-00006 · Cited by 25
Vitale, E., Ungar, A., Maggi, R., Francese, M., Lunati, M., Colaceci, R., Rosso, A. D., Castro, A., Santini, M., Giuli, S., et al. (2010) · EP Europace · doi:10.1093/europace/euq302 · Cited by 24
Use of the implantable loop recorder in children and adolescents
Gass, M., Apitz, C., Salehi-Gilani, S., Ziemer, G., & Hofbeck, M. (2006) · Cardiology in the Young · doi:10.1017/s1047951106001156 · Cited by 24
Syncope in Adults: Terminology, Classification, and Diagnostic Strategy
Jhanjee, R., van Dijk, J. G., Sakaguchi, S., & Benditt, D. G. (2006) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2006.00508.x · Cited by 24
Zile, M. R., Kahwash, R., Sarkar, S., Koehler, J. L., Zielinski, T. M., Mehra, M. R., Fonarow, G. C., Gulati, S., & Butler, J. (2023) · JACC Heart Failure · doi:10.1016/j.jchf.2023.09.014 · Cited by 23
The implantable loop recorder in children
Yeung, B. P. M., & McLEOD, K. A. (2007) · Heart · doi:10.1136/hrt.2007.121855 · Cited by 23
Risk Stratification for Sudden Cardiac Death
Ikeda, T., Yusu, S., Nakamura, K., & Yoshino, H. (2007) · Circulation Journal · doi:10.1253/circj.71.a106 · Cited by 23
Pathophysiology of syncope: current concepts and their development
Benditt, D. G., Fedorowski, A., Sutton, R., & van Dijk, J. G. (2024) · Physiological Reviews · doi:10.1152/physrev.00007.2024 · Cited by 23
Arrocha, A., Klein, G. J., Benditt, D. G., Sutton, R., & Krahn, A. D. (2010) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2010.02857.x · Cited by 22
Self-citationBurkowitz, J., Merzenich, C., Grassme, K. S., & Brüggenjürgen, B. (2016) · European Journal of Preventive Cardiology · doi:10.1177/2047487316632628 · Cited by 22
Management of Postural Tachycardia Syndrome, Inappropriate Sinus Tachycardia and Vasovagal Syncope
Raj, S. R., & Sheldon, R. S. (2016) · Arrhythmia & Electrophysiology Review · doi:10.15420/aer.2016.7.2 · Cited by 24
Paisey, J. R., Yue, A. M., Treacher, K., Roberts, P. R., & Morgan, J. M. (2005) · International Journal of Cardiology · doi:10.1016/j.ijcard.2003.06.020 · Cited by 19
“The role of the implantable loop recorder (ILR) is evolving and it has been shown to be a valuable, safe [3] and cost-effective tool in patients in whom there is clinical suspicion of cardiac rhythm”
BackgroundImplantable loop recorder undersensing mimicking complete heart block
Chrysostomakis, S. I. (2002) · EP Europace · doi:10.1053/eupc.2002.0229 · Cited by 21
“Recently introduced insertable loop recorders (ILR) constitute a new approach to the investigation of dizzy spells and syncope[ 1 ].”
BackgroundInfluentialPerkiömäki, J. S., Thomsen, P. E. B., Kiviniemi, A. M., Messier, M., Huikuri, H. V., & for the CARISMA study investigators (2011) · EP Europace · doi:10.1093/europace/eur166 · Cited by 21
What Have We Learned About Cardiac Arrhythmias?
Zipes, D. P., & Wellens, H. J. J. (2000) · Circulation · doi:10.1161/01.cir.102.suppl_4.iv-52 · Cited by 24
Implant Evaluation of an Insertable Cardiac Monitor Outside the Electrophysiology Lab Setting
PACHULSKI, R. T., Cockrell, J. L., Solomon, H., Yang, F., & Rogers, J. (2013) · PLoS ONE · doi:10.1371/journal.pone.0071544 · Cited by 20
Cardiac Monitoring in Patients with Syncope: Making that Elusive Diagnosis
Subbiah, R. N., Chia, P., Gula, L. J., Klein, G. J., Skanes, A. C., Yee, R., & Krahn, A. D. (2014) · Current Cardiology Reviews · doi:10.2174/1573403x10666140214120056 · Cited by 18
“Currently there are several studies establishing the utility of ICM in the diagnosis of syncope [25-30].”
Self-citationA 4-μW Analog Front End Achieving 2.4 NEF for Long-Term ECG Monitoring
Yang, W., Jiang, H., Yin, Y., & Wang, Z. (2021) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2021.3084152 · Cited by 19
Evaluation rhythm problems in unexplained syncope etiology with implantable loop recorder
Ergül, Y., Tanıdır, İ. C., Özyılmaz, İ., Akdeniz, C., & Tuzcu, V. (2014) · Pediatrics International · doi:10.1111/ped.12530 · Cited by 19
Syncope: Review of Monitoring Modalities
Krahn, A. D., Subbiah, R. N., Gula, L. J., Klein, G. J., Skanes, A. C., & Yee, R. K. (2008) · Current Cardiology Reviews · doi:10.2174/157340308783565447 · Cited by 20
Self-citationDetection of atrial fibrillation with implantable loop recorders in horses
Buhl, R., Hesselkilde, E. M., Carstensen, H., Fenner, M. F., Jespersen, T., Tfelt‐Hansen, J., & Sattler, S. M. (2020) · Equine Veterinary Journal · doi:10.1111/evj.13301 · Cited by 19
Beinart, S. C., Natale, A., Verma, A., Amin, A. J., Kasner, S. E., Diener, H.-C., Greco, M. D., Wilkoff, B. L., Pouliot, E., Franco, N. C., et al. (2018) · American Heart Journal · doi:10.1016/j.ahj.2018.10.002 · Cited by 19
Farwell, D. J., & Sulke, A. N. (2005) · International Journal of Cardiology · doi:10.1016/j.ijcard.2004.10.066 · Cited by 18
Emerging Role of Digital Technology and Remote Monitoring in the Care of Cardiac Patients
Banchs, J. E., & Scher, D. M. (2015) · Medical Clinics of North America · doi:10.1016/j.mcna.2015.02.013 · Cited by 19
Exertional Collapse in the Runner: Evaluation and Management in Fieldside and Office-Based Settings
Childress, M. A., O’Connor, F. G., & Levine, B. D. (2010) · Clinics in Sports Medicine · doi:10.1016/j.csm.2010.03.007 · Cited by 18
Mittal, S., Rogers, J., Sarkar, S., Koehler, J. L., & PASSMAN, R. S. (2019) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2019.03.014 · Cited by 18
Costs and utility of tests in the evaluation of the pediatric patients with syncope
Steinberg, L. A., & Knilans, T. K. (2001) · Progress in Pediatric Cardiology · doi:10.1016/s1058-9813(01)00097-2 · Cited by 16
García–Civera, R., Ruiz‐Granell, R., Morell‐Cabedo, S., Mañez, R. S., FERRERO, A., Martínez-Brotons, Á. M., ROSELLÓ, A., Solana, S. B., & Llácer, Á. (2005) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2005.50029.x · Cited by 18
Mason, P. K., Wood, M. A., Reese, D. B., Lobban, J. H., Mitchell, M. A., & Dimarco, J. (2003) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2003.07.011 · Cited by 18
Is There an Effective Treatment for Neurally Mediated Syncope?
Kapoor, W. N. (2003) · JAMA · doi:10.1001/jama.289.17.2272 · Cited by 18
Laske, T. G., Garshelis, D. L., Iles, T. L., & Iaizzo, P. A. (2021) · Philosophical Transactions of the Royal Society B Biological Sciences · doi:10.1098/rstb.2020.0217 · Cited by 17
Implantable Diagnostic Monitors in the Early Assessment of Syncope and Collapse
Hong, P. S. G., & Sulke, N. (2013) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2012.11.009 · Cited by 17
Jan, S., Wright, D. J., Schäfer, H., Rashid-Fadel, T., & Lewalter, T. (2017) · EP Europace · doi:10.1093/europace/euw304 · Cited by 17
The diagnostic yield from implantable loop recorders in children and young adults
Sreeram, N., Gass, M., Apitz, C., Ziemer, G., Hofbeck, M., Emmel, M., Brockmeier, K., Hitchcock, F., & Bennink, G. B. W. E. (2007) · Clinical Research in Cardiology · doi:10.1007/s00392-007-0635-4 · Cited by 17
“The implantable loop recorder (ILR; Reveal Plus, Medtronic, USA) may be of benefit in selected patients, and there is extensive experience with this device in adults with syncope [2, 8, 9 ]. Although its use in children has also been reported with favourable results, most series have few patients, with relatively shor…”
BackgroundMunchausen's Syndrome by Proxy Identified with an Implantable Electrocardiographic Recorder
Hoorntje, T. M., Langerak, W., & Sreeram, N. (1999) · New England Journal of Medicine · doi:10.1056/nejm199911043411919 · Cited by 17
Lee, S. H., Kim, T.-H., Oh, Y.-S., Oh, S., Choi, J.-I., Kim, J.-B., Nah, J.-C., Im, S. I., Kang, K.-W., Han, S., et al. (2020) · Journal of Korean Medical Science · doi:10.3346/jkms.2020.35.e11 · Cited by 16
Kabra, R., Gopinathannair, R., Sandesara, C. M., Messinger, C., & Olshansky, B. (2009) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2009.02407.x · Cited by 15
Use of implantable and external loop recorders in syncope with unknown causes
Tanno, K. (2017) · Journal of Arrhythmia · doi:10.1016/j.joa.2017.03.006 · Cited by 16
Tabrizi, F., Rosenqvist, M., Bergfeldt, L., & Englund, A. (2006) · Cardiology · doi:10.1159/000096038 · Cited by 16
Benditt, D. G., Adkisson, W. O., Sutton, R., Mears, R. K., & Sakaguchi, S. (2018) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.13265 · Cited by 16
Implantable loop recorder versus conventional diagnostic workup for unexplained recurrent syncope
Solbiati, M., Costantino, G., Casazza, G., Dipaola, F., Galli, A., Furlan, R., Montano, N., & Sheldon, R. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011637 · Cited by 15
Drak-Hernández, Y., Toquero-Ramos, J., Fernández, J. M., Pérez-Pereira, E., Castro-Urda, V., & Fernández-Lozano, I. (2013) · Revista Española de Cardiología · doi:10.1016/j.recesp.2013.06.012 · Cited by 14
“El tiempo medio transcurrido desde el implante del HI al diagnóstico de un evento significativo es considerable y significativamente menor para los pacientes con MD (56 [0-650] dı́as) que para los pacientes con SC (260 [5-947] dı́as [p < 0,001]).”
BackgroundSCHWARTZMAN, D. S., Blagev, D., BROWN, M. L., & Mehra, R. (2006) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2005.00342.x · Cited by 15
Smith, A., Perdue, M., Vojnika, J., Frisch, D. R., & Pavri, B. B. (2020) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-020-00815-w · Cited by 14
Efficacy And Safety Of Implantable Loop Recorder: Experience Of A Center.
Silveira, I., Sousa, M. J., Antunes, N., Silva, V. M. D. S., Roque, C., Pinheiro‐Vieira, A., Lagarto, V., Hipólito-Reis, A., Luz, A., & Torres, S. (2016) · Europe PMC (PubMed Central) · doi:10.4022/jafib.1425 · Cited by 15
The Case of the Migrating Loop Recorder
Hasnie, A. A., Hasnie, A. A., & Assaly, R. (2019) · JACC Case Reports · doi:10.1016/j.jaccas.2019.06.020 · Cited by 14
“was the Medtronic Reveal, which was 19 61 8 mm and required suturing to prevent migration of the device (3).”
Rendimiento diagnóstico de un protocolo de estudio del síncope de causa no aparente
Civera, R. G., Granell, R. R., Cabedo, S. M., Azpíroz, J. C. P., Ros, V. R., Solana, S. B., & Mañez, R. S. (2001) · Revista Española de Cardiología · doi:10.1016/s0300-8932(01)76330-0 · Cited by 14
Sarkar, S., Majumder, S., Koehler, J. L., & Landman, S. R. (2022) · Heart Rhythm O2 · doi:10.1016/j.hroo.2022.10.014 · Cited by 14
“Introduction Subcutaneous implantable cardiac monitors (ICMs) have been used for automatic detection of cardiac arrhythmias and patient symptom–triggered storage of loop-recorded recent electrocardiograms (ECGs).(1,2) ICMs have been used for diagnosing the cause of unexplained syncope,(3,4) for monitoring of recurrent…”
MethodShanmugam, N., & Liew, R. (2012) · Annals of the Academy of Medicine Singapore · doi:10.47102/annals-acadmedsg.v41n3p115 · Cited by 13
Investigating syncope: a review
Gould, P. A., Krahn, A. D., Klein, G. J., Yee, R. K., Skanes, A. C., & Gula, L. J. (2005) · Current Opinion in Internal Medicine · doi:10.1097/01.hco.0000198986.16626.86 · Cited by 14
Self-citationPingitore, A., Peruzzi, M., Clarich, S. C., Palamà, Z., Sciarra, L., & Cavarretta, E. (2023) · Clinical Cardiology · doi:10.1002/clc.24073 · Cited by 11
The implantable loop recorder: a critical review
Graf, D., Pascale, P., Pruvot, E., & Iglesias, F. (2009) · Kardiovask Med · doi:10.4414/cvm.2009.01406 · Cited by 12
Current management of syncope: Treatment alternatives
Morillo, C. A., & Baranchuk, A. (2004) · Current Treatment Options in Cardiovascular Medicine · doi:10.1007/s11936-004-0021-8 · Cited by 11
“Bradycardic causes that include neurally mediated syncope and paroxysmal AV block are by far the most frequent [ 13 ].”
Backgroundde Cardiología, G. D. T. D. L. S. E. (2005) · Revista Española de Cardiología · doi:10.1157/13071892 · Cited by 11
Nonarrhythmic syncope documented by an implantable loop recorder (an ISSUE substudy)
Brignole, M., Menozzi, C., Moya‐Mitjans, À., García–Civera, R., Donateo, P., Puggioni, E., Migliorini, R., & Navarro, X. (2002) · The American Journal of Cardiology · doi:10.1016/s0002-9149(02)02577-8 · Cited by 11
Saggu, D. K., Madappa, N. U., Sarkar, S., Sathiyamoorthy, A., Dash, S., Veerendranath Reddy, P., Rajan, V., & Calambur, N. (2024) · Indian Pacing and Electrophysiology Journal · doi:10.1016/j.ipej.2024.08.003 · Cited by 10
“Subcutaneous insertable cardiac monitors (ICM) have been used for continuous longer term automatic detection of cardiac arrhythmias and patient symptom triggered storage of loop recorded recent ECG. [11], [12] ICMs are minimally invasive and are implanted in the subcutaneous space.”
MethodManaging the military patient with syncope
Parsons, I., Cox, A., Mollan, I. A., & Boos, C. J. (2015) · Journal of the Royal Army Medical Corps · doi:10.1136/jramc-2015-000493 · Cited by 10
Quality of ECG Monitoring with a Miniature ECG Recorder
Janata, A., Lemmert, M. E., Russell, J. K., Gehman, S. E., Fleischhackl, R. H., Robak, O., Pernicka, E., Sterz, F. R., & Gorgels, A. P. M. (2008) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2008.01070.x · Cited by 10
The Implantable Loop Recorder: Current Uses, Future Directions
Kanjwal, K., Figueredo, V. M., Karabin, B. L., & Grubb, B. P. (2011) · Cited by 10
Conti, S., Reiffel, J. A., Gersh, B. J., Kowey, P. R., Wachter, R., Halperin, J. L., Kaplon, R. E., Pouliot, E., & Verma, A. (2017) · Journal of Atrial Fibrillation · doi:10.4022/jafib.1551 · Cited by 10
Chokesuwattanaskul, R., Safadi, A. R., Ip, R., Waraich, H. K., Hudson, O., & Ip, J. H. (2019) · Journal of Biomedical Science and Engineering · doi:10.4236/jbise.2019.128030 · Cited by 9
“Implantable cardiac monitor has become the standard of care for evaluating patient with unexplained syncope and arrhythmia and it is also widely used as AF surveillance in patients with cryptogenic stroke [4, 14, 15].”
BackgroundSchuchert, A., Behrens, G., & Meinertz, T. (2002) · Zeitschrift für Kardiologie · doi:10.1007/s392-002-8373-4 · Cited by 10
Butler, J., Kahwash, R., Khan, M. S., Gerritse, B., Laechelt, A., Wehking, J., Sarkar, S., Dorn, B. V., Laager, V., Patel, N., et al. (2025) · European Journal of Heart Failure · doi:10.1002/ejhf.3595 · Cited by 9
Sensing Performance of a New Wireless Implantable Loop Recorder: A 12-Month Follow Up Study
Jacob, S., Kommuri, N. V. A., ZALAWADIYA, S. K., Meissner, M. D., & Lieberman, R. A. (2010) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2009.02682.x · Cited by 9
Loop recorders for syncope evaluation: what is the evidence?
Cheung, C. C., & Krahn, A. D. (2016) · Expert Review of Medical Devices · doi:10.1080/17434440.2016.1243463 · Cited by 9
“rhythm correlation (most commonly bradycardia) [10].”
Self-citationValue of Ambulatory Electrocardiographic Monitoring in Syncope
Giada, F., & Bartoletti, A. (2015) · Cardiology Clinics · doi:10.1016/j.ccl.2015.04.004 · Cited by 9
Effect of stored electrograms on management in the paced patient
Huikuri, H. V. (2000) · The American Journal of Cardiology · doi:10.1016/s0002-9149(00)01190-5 · Cited by 9
Die Notfalltherapie bradykarder Herzrhythmusstörungen
Heinroth, K. M., Werdan, K., WEISMÜLLER, P., & Trappe, H. (2001) · Steinkopff eBooks · doi:10.1007/978-3-642-57631-7_5 · Cited by 9
Monitoring devices for falls and syncope
Seifer, C. M., & Parry, S. W. (2002) · Clinics in Geriatric Medicine · doi:10.1016/s0749-0690(02)00011-3 · Cited by 9
Early experience with a novel ambulatory monitor
Russell, J. K., & Gehman, S. E. (2007) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2007.06.013 · Cited by 9
Guía de práctica clínica para el diagnóstico y manejo del síncope (versión 2009)
Moya‐Mitjans, À., Sutton, R., Ammirati, F., Blanc, J., Brignole, M., Dahm, J. B., Deharo, J., Gajek, J. J., Gjesdal, K., Krahn, A. D., et al. (2009) · Revista Española de Cardiología · doi:10.1016/s0300-8932(09)73132-x · Cited by 23
Self-citationPronóstico del presíncope en pacientes con cardiopatía estructural
Reverte, J. G., Lázaro, C. L., Garcı́a-Alberola, A., Zapata, M. G., García, R. G., Sánchez-Muñoz, J.-J., Sánchez, J. M., & Chávarri, M. V. (2004) · Revista Española de Cardiología · doi:10.1016/s0300-8932(04)77163-8 · Cited by 8
Patient selection for ambulatory cardiac monitoring in the Indian healthcare environment
Shrivastav, M., Shrivastav, R., Makkar, J. S., & Biffi, M. (2013) · Heart Asia · doi:10.1136/heartasia-2012-010228 · Cited by 8
“36 39 The diagnostic yield of any ambulatory monitoring system is indeed related to the length of the monitoring period.”
BackgroundTrends in Subcutaneous Cardiac Monitoring Technology
Kohno, R., Nantsupawat, T., & Benditt, D. G. (2018) · Journal of Innovations in Cardiac Rhythm Management · doi:10.19102/icrm.2018.090703 · Cited by 8
Benditt, D. G., Ermiş, C., Pham, S., Hiltner, L., Vrudney, A., Lurie, K. G., & Sakaguchi, S. (2003) · Journal of Interventional Cardiac Electrophysiology · doi:10.1023/a:1026220020639 · Cited by 8
Trim, G., Krahn, A. D., Klein, G. J., Skanes, A. C., & Yee, R. K. (2003) · Cardiac Electrophysiology Review · doi:10.1023/b:cepr.0000023168.26698.1e · Cited by 8
“A preliminary step to confirm severe cardioinhibition prior to instituting permanent pacing could include the use of prolonged monitoring to document the patient’s heart rate during spontaneouslyoccurring syncope [33].”
BackgroundSelf-citationOrmaetxe, J. M., S�ez, R., Arkotxa, M. F., & Martínez-Alday, J. D. (2004) · Pediatric Cardiology · doi:10.1007/s00246-004-0687-4 · Cited by 8
Outcome of patients with syncope beyond the implantable loop recorder
Merlos, P., Rúmiz, E., Ruiz‐Granell, R., Martínez, A., Izquierdo, M., Ferrero, A., Domínguez, E., Sanchez, J. M., Morell, S., & García–Civera, R. (2012) · EP Europace · doi:10.1093/europace/eus264 · Cited by 8
“75] 2 [1–4] 0.”
Economic value of insertable cardiac monitors in unexplained syncope in the United States
Sutton, B. S., Bermingham, S. L., Diamantopoulos, A., Rosemas, S. C., Tsintzos, S. I., Xia, Y., & Reynolds, M. R. (2021) · Open Heart · doi:10.1136/openhrt-2020-001263 · Cited by 7
Paylos, J. M., & Aguilar, R. (2001) · Revista Española de Cardiología · doi:10.1016/s0300-8932(01)76331-2 · Cited by 7
Clinical Utility of Implantable Loop Recorders
Houmsse, M., Ishola, A., & Daoud, E. G. (2014) · Postgraduate Medicine · doi:10.3810/pgm.2014.03.2738 · Cited by 7
Current rare indications and future directions for implantable loop recorders
Wechselberger, S., Piorkowski, C., & Pohl, M. (2016) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-016-0475-x · Cited by 7
A single center experience on the clinical utility evaluation of an insertable cardiac monitor
Li, Y., Nantsupawat, T., Olson, M. D., Tholakanahalli, V. N., Adabağ, S., Zhong, W., Benditt, D. G., & Li, J. (2018) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2018.05.002 · Cited by 7
Syncope in the Elderly: New Trends in Diagnostic Approach and Nonpharmacologic Management
Luria, D. M., & Shen, W. K. (2001) · The American Journal of Geriatric Cardiology · doi:10.1111/j.1076-7460.2001.00840.x · Cited by 7
Trends in syncope testing and admissions in the USA from 2006 through 2019
Ruzieh, M., Bai, C., Kimmel, S. E., Goldberger, Z. D., Dasa, O., Petersen, J. W., Smoot, M., Edwards, E. S., Kamisetty, S. R., & Mardini, M. (2024) · Clinical Autonomic Research · doi:10.1007/s10286-024-01089-2 · Cited by 6
“Long-term monitoring may provide better diagnostic information compared to routine testing in patients with unexplained syncope [12, 13].”
Lee, S.-Y., Lee, H.-Y., Kung, C.-H., Su, P.-H., & Chen, J. (2022) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2022.3201328 · Cited by 6
Use of Implantable Loop Recorders to Unravel the Cause of Unexplained Syncope
Puri, A., & Srivastava, R. K. (2013) · Indian Pacing and Electrophysiology Journal · doi:10.1016/s0972-6292(16)30606-4 · Cited by 6
“005)[19].”
Syncope in Patients with Organic Heart Disease
Olshansky, B., & Sullivan, R. M. (2015) · Cardiology Clinics · doi:10.1016/j.ccl.2015.04.013 · Cited by 6
CURRENT METHODS OF AMBULATORY ELECTROCARDIOGRAM MONITORING. TECHNICAL ASPECTS
Pervova, E. V. (2017) · The Clinician · doi:10.17650/1818-8338-2016-10-4-16-28 · Cited by 6
Angaran, P., Klein, G. J., Yee, R. K., Skanes, A. C., Gula, L. J., Leong‐Sit, P., & Krahn, A. D. (2011) · Neurologic Clinics · doi:10.1016/j.ncl.2011.07.005 · Cited by 6
Self-citation
Metadata
- Authors
- Krahn, A. D., Klein, G. J., Yee, R., Takle-Newhouse, T., & Norris, C.
- Affiliations
- Western University (CA)
- From the Division of Cardiology, University of Western Ontario, London, Ontario, Canada, and Medtronic, Minneapolis, Minn (T.T.-N.).
- Venue
- Circulation
- Published
- 1999-01-26
- Volume
- 99
- Issue
- 3
- Pages
- 406-410
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2006949147
- Semantic Scholar
- 23b308c400504de7e0f85483f49bf75ca93e86b0
- Cited by
- 360
- References
- 27
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 10 · 2023: 5 · 2022: 3 · 2021: 7 · 2020: 5 · 2019: 6 · 2018: 12 · 2017: 22 · 2016: 12 · 2015: 13 · 2014: 13 · 2013: 17 · 2012: 9
- FWCI
- 24.90
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Circulation (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Heart and Stroke Foundation of Canada
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Syncope and Autonomic Disorders
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- syncope, implantable loop recorder, prolonged cardiac monitoring, arrhythmia detection, neurally mediated syncope, bradycardia, tachycardia, presyncope, recurrent syncope
- MeSH terms
- Adult, Aged, Arrhythmias, Cardiac, Female, Humans, Male, Middle Aged, Recurrence, Syncope, Electrocardiography, Ambulatory, Tilt-Table Test, Prostheses and Implants
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review