Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 263

The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.

Microvascular Function Relates to Insulin Sensitivity and Blood Pressure in Normal Subjects

Serné, Erik H., Stehouwer, Coen D. A., ter Maaten, Jan C., ter Wee, Piet M., Rauwerda, Jan A., Donker, Ab J. M., Gans, Reinold O. B.·1999·Circulation

Abstract

Background —A strong but presently unexplained inverse association between blood pressure and insulin sensitivity has been reported. Microvascular vasodilator capacity may be a common antecedent linking insulin sensitivity to blood pressure. To test this hypothesis, we studied 18 normotensive and glucose-tolerant subjects showing a wide range in insulin sensitivity as assessed with the hyperinsulinemic, euglycemic clamp technique. Methods and Results —Blood pressure was measured by 24-hour ambulatory blood pressure monitoring. Videomicroscopy was used to measure skin capillary density and capillary recruitment after arterial occlusion. Skin blood flow responses after iontophoresis of acetylcholine and sodium nitroprusside were evaluated by laser Doppler flowmetry. Insulin sensitivity correlated with 24-hour systolic blood pressure (24-hour SBP; r =−0.50, P <0.05). Capillary recruitment and acetylcholine-mediated vasodilatation were strongly and positively related to insulin sensitivity ( r =0.84, P <0.001; r =0.78, P <0.001, respectively), and capillary recruitment was inversely related to 24-hour SBP ( r =−0.53, P <0.05). Waist-to-hip ratio showed strong associations with insulin sensitivity, blood pressure, and the measures of microvascular function but did not confound the associations between these variables. Subsequent regression analysis showed that the association between insulin sensitivity and blood pressure was not independent of the estimates of microvascular function, and part of the variation in both blood pressure ( R 2 =38%) and insulin sensitivity ( R 2 =71%) could be explained by microvascular function. Conclusions —Insulin sensitivity and blood pressure are associated well within the physiological range. Microvascular function strongly relates to both, consistent with a central role in linking these variables.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.99.7.896

Cites

36 of 36 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 36 references

Cited by

See all 263

Metadata

Authors
Serné, E. H., Stehouwer, C. D. A., ter Maaten, J. C., ter Wee, P. M., Rauwerda, J. A., Donker, A. J. M., & Gans, R. O. B.
Venue
Circulation
Published
1999-02-23
Volume
99
Issue
7
Pages
896-902
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2102131871
Cited by
263
References
36
FWCI
8.30
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Microvascular Function Relates to Insulin Sensitivity and Blood Pressure in Normal Subjects. https://app.cochat.ai/papers/10.1161/01.cir.99.7.896
The paper
Serné, E. H., Stehouwer, C. D. A., ter Maaten, J. C., ter Wee, P. M., Rauwerda, J. A., Donker, A. J. M., & Gans, R. O. B. (1999). Microvascular Function Relates to Insulin Sensitivity and Blood Pressure in Normal Subjects. Circulation. https://doi.org/10.1161/01.cir.99.7.896

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.