Ambulatory Arterial Stiffness Index Derived From 24-Hour Ambulatory Blood Pressure Monitoring
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
We hypothesized that 1 minus the slope of diastolic on systolic pressure during 24-hour ambulatory monitoring (ambulatory arterial stiffness index [AASI]) might reflect arterial stiffness. We compared AASI with established measures of arterial stiffness and studied its distribution in Chinese and European populations. We used 90207 SpaceLabs monitors and the SphygmoCor device to measure AASI, central and peripheral pulse pressures, the central (CAIx) and peripheral (PAIx) systolic augmentation indexes, and aortic pulse wave velocity. In 166 volunteers, the correlation coefficient between AASI and pulse wave velocity was 0.51 ( P <0.0001). In 348 randomly recruited Chinese subjects, AASI correlated ( P <0.0001) with CAIx ( r =0.48), PAIx ( r =0.50), and central pulse pressure ( r =0.50). AASI increased with age and mean arterial pressure but decreased with body height. Both before and after adjustment for arterial wave reflections by considering height and heart rate as covariates, AASI correlated more ( P <0.0001) closely with CAIx and PAIx than 24-hour pulse pressure. Among normotensive subjects, the 95th percentile of AASI was 0.55 in Chinese and 0.57 in 1617 Europeans enrolled in the International Database on Ambulatory Blood Pressure Monitoring. The upper boundary of the 95% prediction interval of AASI in relation to age ranged from 0.53 at 20 years to 0.72 at 80 years. In conclusion, AASI is a new index of arterial stiffness that can be easily measured under ambulatory conditions. Pending additional validation in outcome studies, normal values of AASI are probably <0.50 and 0.70 in young and older subjects, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An analysis of variance test for normality (complete samples)
SHAPIRO, S. S., & WILK, M. B. (1965) · Biometrika · doi:10.1093/biomet/52.3-4.591 · Cited by 23,480
(2013) · European Heart Journal · doi:10.1093/eurheartj/eht151 · Cited by 13,655
(2003) · Journal of Hypertension · doi:10.1097/00004872-200306000-00001 · Cited by 3,027
Mancia, G., Rosei, E. A., Cífková, R., DeBacker, G., Erdine, S. E., Fagard, R., Farsang, C., Heagerty, A. M., Kawecka-Jaszcs, K., Kiowski, W., et al. (2003) · Lirias · doi:10.1097/01.hjh.0000059051.65882.32 · Cited by 2,601
Self-citationHemodynamic Patterns of Age-Related Changes in Blood Pressure: The Framingham Heart Study
Franklin, S. S., Gustin, W., Wong, N. D., Larson, M. G., Weber, M. A., Kannel, W. B., & Levy, D. (1997) · Circulation · doi:10.1161/01.cir.96.1.308 · Cited by 2,321
Mitchell, G. F., Parise, H., Benjamin, E. J., Larson, M. G., Keyes, M. J., Vita, J. A., Vasan, R. S., & Levy, D. (2004) · Hypertension · doi:10.1161/01.hyp.0000128420.01881.aa · Cited by 1,501
Safar, M. E., Levy, B. I., & Struijker-Boudier, H. (2003) · Circulation · doi:10.1161/01.cir.0000069826.36125.b4 · Cited by 1,197
Pauca, A. L., O’Rourke, M. F., & Kon, N. D. (2001) · Hypertension · doi:10.1161/hy1001.096106 · Cited by 1,179
Clinical applications of arterial stiffness; definitions and reference values
O'Rourke, M. F., Staessen, J. A., Vlachopoulos, C., Duprez, D., & Plante, G. E. E. (2002) · American Journal of Hypertension · doi:10.1016/s0895-7061(01)02319-6 · Cited by 1,100
Self-citationArterial stiffness, wave reflections, and the risk of coronary artery disease
Weber, T., Auer, J., O’Rourke, M. F., Kvas, E., Lassnig, E., Berent, R., & Eber, B. (2004) · Circulation · doi:10.1161/01.cir.0000105767.94169.e3 · Cited by 1,081
Pulse Pressure: A Predictor of Long-term Cardiovascular Mortality in a French Male Population
Benetos, A., Safar, M., Rudnichi, A., Smulyan, H., Richard, J.-L., Ducimetière, P., & Guize, L. (1997) · Hypertension · doi:10.1161/01.hyp.30.6.1410 · Cited by 1,034
Reproducibility of pulse wave velocity and augmentation index measured by pulse wave analysis
Wilkinson, I. B., Fuchs, S. A., Jansen, I. M., Spratt, J. C., Murray, G. D., Cockcroft, J. R., & Webb, D. J. (1998) · Journal of Hypertension · doi:10.1097/00004872-199816121-00033 · Cited by 924
Clinical applications of arterial stiffness, Task Force III: recommendations for user procedures
Van Bortel, L. M., Duprez, D., Starmans-Kool, M. J., Safar, M. E., Giannattasio, C., Cockcroft, J., Kaiser, D. R., & Thuillez, C. (2002) · American Journal of Hypertension · doi:10.1016/s0895-7061(01)02326-3 · Cited by 630
Benetos, A. (2002) · American Journal of Hypertension · doi:10.1016/s0895-7061(02)03029-7 · Cited by 486
Accuracy of the SpaceLabs 90207 determined by the British Hypertension Society Protocol
O??Brien, E., Mee, F., Atkins, N., & O??Malley, K. (1991) · Journal of Hypertension · doi:10.1097/00004872-199106000-00016 · Cited by 451
Self-citationDolan, E., Thijs, L., Li, Y., Atkins, N., McCormack, P., McClory, S., O’Brien, E., Staessen, J. A., & Stanton, A. V. (2006) · Hypertension · doi:10.1161/01.hyp.0000200699.74641.c5 · Cited by 394
Self-citationPulse pressure in essential hypertension: clinical and therapeutical implications
Safar, M. E. (1989) · Journal of Hypertension · doi:10.1097/00004872-198910000-00001 · Cited by 253
O??Brien, E., Murphy, J., Tyndall, A., Atkins, N., Mee, F., McCarthy, G., Staessen, J., Cox, J., & O??Malley, K. (1991) · Journal of Hypertension · doi:10.1097/00004872-199104000-00007 · Cited by 251
Self-citationSmulyan, H., Marchais, S. J., Pannier, B., Guerin, A. P., Safar, M. E., & London, G. M. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00056-4 · Cited by 242
Pulse Pressure, Arterial Stiffness, and Drug Treatment of Hypertension
Van Bortel, L. M. A. B., Struijker-Boudier, H. A. J., & Safar, M. E. (2001) · Hypertension · doi:10.1161/hy1001.095773 · Cited by 241
Factors That Affect Blood Pressure Variability A Community-Based Study in Ohasama, Japan
Imai, Y. (1997) · American Journal of Hypertension · doi:10.1016/s0895-7061(97)00277-x · Cited by 143
Staessen, J. A., O??Brien, E. T., Amery, A. K., Atkins, N., Baumgart, P., Cort, P. D., Degaute, J.-P., Dolenc, P., Gaudemaris, R. D., Enstr??m, I., et al. (1994) · Journal of Hypertension · doi:10.1097/00004872-199400127-00001 · Cited by 132
Self-citationA Consensus View on the Technique of Ambulatory Blood Pressure Monitoring
Staessen, J. A., Fagard, R., Thijs, L., & Amery, A. (1995) · Hypertension · doi:10.1161/01.hyp.26.6.912 · Cited by 119
Self-citationAn epidemiological approach to ambulatory blood pressure monitoring:the Belgian Population Study.
Staessen, J. A., Bieniaszewski, L., O'Brien, E. T., Imai, Y., & Fagard, R. (1996) · PubMed · Cited by 113
Self-citationReflection in the arterial system and the risk of coronary heart disease
Hayashi, T., Nakayama, Y., Tsumura, K., Yoshimaru, K., & Ueda, H. (2002) · American Journal of Hypertension · doi:10.1016/s0895-7061(02)02260-4 · Cited by 109
Evidence that new antihypertensives are superior to older drugs
Staessen, J. A., & Birkenhäger, W. H. (2005) · The Lancet · doi:10.1016/s0140-6736(05)67147-4 · Cited by 92
Self-citationEffects of Heart Rate Changes on Arterial Distensibility in Humans
Giannattasio, C., Vincenti, A., Failla, M., Capra, A., Cirò, A., Ceglia, S. D., Gentile, G., Brambilla, R., & Mancia, G. (2003) · Hypertension · doi:10.1161/01.hyp.0000085199.33254.15 · Cited by 85
SYSTOLIC AND DIASTOLIC BLOOD PRESSURE ESTIMATION, WITH SPECIAL REFERENCE TO THE AUDITORY METHOD
MacWilliam, J. A., & Melvin, G. S. (1914) · BMJ · doi:10.1136/bmj.1.2778.693 · Cited by 35
REID, J. (1994) · Journal of Hypertension · doi:10.1097/00004872-199401000-00001 · Cited by 28
Cited by
(2013) · European Heart Journal · doi:10.1093/eurheartj/eht151 · Cited by 13,655
Mancia, G., Fagard, R., Narkiewicz, K., Redón, J., Zanchetti, A., Böhm, M., Christiaens, T., Cifkova, R., De Backer, G., Dominiczak, A., et al. (2013) · Journal of Hypertension · doi:10.1097/01.hjh.0000431740.32696.cc · Cited by 5,655
European Society of hypertension position paper on ambulatory blood pressure monitoring
O’Brien, E., Parati, G., Stergiou, G., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328363e964 · Cited by 1,419
Self-citationMancia, G., Fagard, R., Narkiewicz, K., Redon, J., Zanchetti, A., Böhm, M., Christiaens, T., Cifkova, R., De Backer, G., Dominiczak, A., et al. (2014) · Blood Pressure · doi:10.3109/08037051.2014.868629 · Cited by 739
Daskalopoulou, S. S., Rabi, D. M., Zarnke, K. B., Dasgupta, K., Nerenberg, K., Cloutier, L., Gelfer, M., Lamarre-Cliche, M., Milot, A., Bolli, P., et al. (2015) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2015.02.016 · Cited by 684
Metadata
- Authors
- Li, Y., Wang, J.-G., Dolan, E., Gao, P.-J., Guo, H.-F., Nawrot, T., Stanton, A. V., Zhu, D.-L., O’Brien, E., & Staessen, J. A.
- Venue
- Hypertension
- Published
- 2006-03
- Volume
- 47
- Issue
- 3
- Pages
- 359-364
- ISSN
- 0194-911X (ISSN-L)
- 1524-4563
- OpenAlex
- W2144140589
- Cited by
- 371
- References
- 29
- FWCI
- 18.37
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.