A Consensus View on the Technique of Ambulatory Blood Pressure Monitoring
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
This review, based on the Fourth International Consensus Conference on Ambulatory Blood Pressure Monitoring (Leuven, Belgium, 1994), deals with the technical aspects of ambulatory blood pressure monitoring. Ambulatory blood pressure monitoring by noninvasive intermittent techniques is widely used despite artifacts due to cuff size, movement, body position, short-term blood pressure variability, and interference with sleep. The performance of the currently available monitors under truly ambulatory conditions and during exercise remains a matter of debate, as are the procedures required to validate portable monitors under these circumstances. There is general agreement that whenever a monitor is to be used in special populations, such as older subjects or pregnant women, or in special conditions, such as exercise, a specific demonstration of its accuracy in these defined subgroups or conditions is warranted. Whether the auscultatory or oscillometric method is preferred remains controversial because each technique has specific advantages and disadvantages and because both can provide accurate results. Most experts in the field strongly believe that manufacturers should disclose the algorithms of their devices and that they should specify all changes made to the hardware and software of a previously validated monitor. Finally, the development of the volume-clamp method, which makes continuous noninvasive registration of blood pressure at the finger possible in both stationary and ambulatory conditions, opens new perspectives in research, in particular in relation to short-term blood pressure variability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Pagani, M., Lombardi, F., Guzzetti, S., Rimoldi, O., Furlan, R., Pizzinelli, P., Sandrone, G., Malfatto, G., Dell'Orto, S., & Piccaluga, E. (1986) · Circulation Research · doi:10.1161/01.res.59.2.178 · Cited by 4,130
Parati, G., Casadei, R., Groppelli, A., Di Rienzo, M., & Mancia, G. (1989) · Hypertension · doi:10.1161/01.hyp.13.6.647 · Cited by 899
Noninvasive automatic determination of mean arterial pressure
Ramsey, M. (1979) · Medical and Biological Engineering and Computing · doi:10.1007/bf02440948 · Cited by 287
Quantitative analysis of the 24-hour blood pressure and heart rate patterns in young men.
Degaute, J. P., van de Borne, P., Linkowski, P., & Van Cauter, E. (1991) · Hypertension · doi:10.1161/01.hyp.18.2.199 · Cited by 243
Continuous vs intermittent blood pressure measurements in estimating 24-hour average blood pressure.
di Rienzo, M., Grassi, G., Pedotti, A., & Mancia, G. (1983) · Hypertension · doi:10.1161/01.hyp.5.2.264 · Cited by 239
Effect of Vertical Displacement of the Arm on Indirect Blood-Pressure Measurement
Mitchell, P. L., Parlin, R. W., & Blackburn, H. (1964) · New England Journal of Medicine · doi:10.1056/nejm196407092710204 · Cited by 125
Cited by
Redon, J., Campos, C., Narciso, M. L., Rodicio, J. L., Pascual, J. M., & Ruilope, L. M. (1998) · Hypertension · doi:10.1161/01.hyp.31.2.712 · Cited by 420
Ambulatory Arterial Stiffness Index Derived From 24-Hour Ambulatory Blood Pressure Monitoring
Li, Y., Wang, J.-G., Dolan, E., Gao, P.-J., Guo, H.-F., Nawrot, T., Stanton, A. V., Zhu, D.-L., O’Brien, E., & Staessen, J. A. (2006) · Hypertension · doi:10.1161/01.hyp.0000200695.34024.4c · Cited by 371
Self-citationUtility of the Photoplethysmogram in Circulatory Monitoring
Reisner, A., Shaltis, P. A., McCombie, D., Asada, H. H., Warner, D. S., & Warner, M. A. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31816c89e1 · Cited by 366
Reference Values for Self-recorded Blood Pressure: A Meta-analysis of Summary Data
Thijs, L., Staessen, J. A., Celis, H., de Gaudemaris, R., Imai, Y., Julius, S., & Fagard, R. (1998) · Archives of Internal Medicine · doi:10.1001/archinte.158.5.481 · Cited by 143
Self-citationMoore, T. J., Vollmer, W. M., Appel, L. J., Sacks, F. M., Svetkey, L. P., Vogt, T. M., Conlin, P. R., Simons-Morton, D. G., Carter-Edwards, L., & Harsha, D. W. (1999) · Hypertension · doi:10.1161/01.hyp.34.3.472 · Cited by 139
Metadata
- Authors
- Staessen, J. A., Fagard, R., Thijs, L., & Amery, A.
- Venue
- Hypertension
- Published
- 1995-12
- Volume
- 26
- Issue
- 6
- Pages
- 912-918
- ISSN
- 0194-911X (ISSN-L)
- 1524-4563
- OpenAlex
- W2161864398
- Cited by
- 119
- References
- 7
- FWCI
- 4.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Consensus View on the Technique of Ambulatory Blood Pressure Monitoring. https://app.cochat.ai/papers/10.1161/01.hyp.26.6.912
- The paper
- Staessen, J. A., Fagard, R., Thijs, L., & Amery, A. (1995). A Consensus View on the Technique of Ambulatory Blood Pressure Monitoring. Hypertension. https://doi.org/10.1161/01.hyp.26.6.912
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.