Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 308

The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.

Validation of a Generalized Transfer Function to Noninvasively Derive Central Blood Pressure During Exercise

Open access
Sharman, James E., Lim, Richard, Qasem, Ahmad M., Coombes, Jeff S., Burgess, Malcolm I., Franco, Jeff, Garrahy, Paul, Wilkinson, Ian B., Marwick, Thomas H.·2006·Hypertension

Abstract

Exercise brachial blood pressure (BP) predicts mortality, but because of wave reflection, central (ascending aortic) pressure differs from brachial pressure. Exercise central BP may be clinically important, and a noninvasive means to derive it would be useful. The purpose of this study was to test the validity of a noninvasive technique to derive exercise central BP. Ascending aortic pressure waveforms were recorded using a micromanometer-tipped 6F Millar catheter in 30 patients (56±9 years; 21 men) undergoing diagnostic coronary angiography. Simultaneous recordings of the derived central pressure waveform were acquired using servocontrolled radial tonometry at rest and during supine cycling. Pulse wave analysis of the direct and derived pressure signals was performed offline (SphygmoCor 7.01). From rest to exercise, mean arterial pressure and heart rate were increased by 20±10 mm Hg and 15±7 bpm, respectively, and central systolic BP ranged from 77 to 229 mm Hg. There was good agreement and high correlation between invasive and noninvasive techniques with a mean difference (±SD) for central systolic BP of −1.3±3.2 mm Hg at rest and −4.7±3.3 mm Hg at peak exercise (for both r =0.995; P <0.001). Conversely, systolic BP was significantly higher peripherally than centrally at rest (155±33 versus 138±32 mm Hg; mean difference, −16.3±9.4 mm Hg) and during exercise (180±34 versus 164±33 mm Hg; mean difference, −15.5±10.4 mm Hg; for both P <0.001). True myocardial afterload is not reliably estimated by peripheral systolic BP. Radial tonometry and pulse wave analysis is an accurate technique for the noninvasive determination of central BP at rest and during exercise.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.hyp.0000223013.60612.72

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 25 references

Cited by

See all 308

Metadata

Authors
Sharman, J. E., Lim, R., Qasem, A. M., Coombes, J. S., Burgess, M. I., Franco, J., Garrahy, P., Wilkinson, I. B., & Marwick, T. H.
Venue
Hypertension
Published
2006-06
Volume
47
Issue
6
Pages
1203-1208
ISSN
  • 0194-911X (ISSN-L)
  • 1524-4563
OpenAlex
W2127374591
Cited by
308
References
25
FWCI
10.28
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Validation of a Generalized Transfer Function to Noninvasively Derive Central Blood Pressure During Exercise. https://app.cochat.ai/papers/10.1161/01.hyp.0000223013.60612.72
The paper
Sharman, J. E., Lim, R., Qasem, A. M., Coombes, J. S., Burgess, M. I., Franco, J., Garrahy, P., Wilkinson, I. B., & Marwick, T. H. (2006). Validation of a Generalized Transfer Function to Noninvasively Derive Central Blood Pressure During Exercise. Hypertension. https://doi.org/10.1161/01.hyp.0000223013.60612.72

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.