The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Validation of a Generalized Transfer Function to Noninvasively Derive Central Blood Pressure During Exercise
Open accessAbstract
Exercise brachial blood pressure (BP) predicts mortality, but because of wave reflection, central (ascending aortic) pressure differs from brachial pressure. Exercise central BP may be clinically important, and a noninvasive means to derive it would be useful. The purpose of this study was to test the validity of a noninvasive technique to derive exercise central BP. Ascending aortic pressure waveforms were recorded using a micromanometer-tipped 6F Millar catheter in 30 patients (56±9 years; 21 men) undergoing diagnostic coronary angiography. Simultaneous recordings of the derived central pressure waveform were acquired using servocontrolled radial tonometry at rest and during supine cycling. Pulse wave analysis of the direct and derived pressure signals was performed offline (SphygmoCor 7.01). From rest to exercise, mean arterial pressure and heart rate were increased by 20±10 mm Hg and 15±7 bpm, respectively, and central systolic BP ranged from 77 to 229 mm Hg. There was good agreement and high correlation between invasive and noninvasive techniques with a mean difference (±SD) for central systolic BP of −1.3±3.2 mm Hg at rest and −4.7±3.3 mm Hg at peak exercise (for both r =0.995; P <0.001). Conversely, systolic BP was significantly higher peripherally than centrally at rest (155±33 versus 138±32 mm Hg; mean difference, −16.3±9.4 mm Hg) and during exercise (180±34 versus 164±33 mm Hg; mean difference, −15.5±10.4 mm Hg; for both P <0.001). True myocardial afterload is not reliably estimated by peripheral systolic BP. Radial tonometry and pulse wave analysis is an accurate technique for the noninvasive determination of central BP at rest and during exercise.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
McDonald's blood flow in arteries; theoretical, experimental and clinical principles
(1992) · General Pharmacology: The Vascular System · doi:10.1016/0306-3623(92)90079-y · Cited by 2,388
The CAFE Investigators, CAFE Steering Committee and Writing Committee, Williams, B., Lacy, P. S., Thom, S. M., Cruickshank, K., Stanton, A., Collier, D., Hughes, A. D., Thurston, H., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.595496 · Cited by 1,645
Chen, C.-H., Nevo, E., Fetics, B., Pak, P. H., Yin, F. C. P., Maughan, W. L., & Kass, D. A. (1997) · Circulation · doi:10.1161/01.cir.95.7.1827 · Cited by 1,307
Pauca, A. L., O’Rourke, M. F., & Kon, N. D. (2001) · Hypertension · doi:10.1161/hy1001.096106 · Cited by 1,179
Arterial stiffness, wave reflections, and the risk of coronary artery disease
Weber, T., Auer, J., O’Rourke, M. F., Kvas, E., Lassnig, E., Berent, R., & Eber, B. (2004) · Circulation · doi:10.1161/01.cir.0000105767.94169.e3 · Cited by 1,081
KARAMANOGLU, M., O'ROURKE, M. F., AVOLIO, A. P., & KELLY, R. P. (1993) · European Heart Journal · doi:10.1093/eurheartj/14.2.160 · Cited by 873
Arterial wave reflections and survival in end-stage renal failure
London, G. M., Blacher, J., Pannier, B., Guérin, A. P., Marchais, S. J., & Safar, M. E. (2001) · Hypertension · doi:10.1161/01.hyp.38.3.434 · Cited by 853
Experimental Subendocardial Ischemia in Dogs with Normal Coronary Arteries
BUCKBERG, G. D., FIXLER, D. E., ARCHIE, J. P., & HOFFMAN, J. I. E. (1972) · Circulation Research · doi:10.1161/01.res.30.1.67 · Cited by 845
Central Pulse Pressure and Mortality in End-Stage Renal Disease
Safar, M. E., Blacher, J., Pannier, B., Guerin, A. P., Marchais, S. J., Guyonvarc’h, P.-M., & London, G. M. (2002) · Hypertension · doi:10.1161/hy0202.098325 · Cited by 805
Singh, J. P., Larson, M. G., Manolio, T. A., O’Donnell, C. J., Lauer, M., Evans, J. C., & Levy, D. (1999) · Circulation · doi:10.1161/01.cir.99.14.1831 · Cited by 461
Cited by
Central blood pressure: current evidence and clinical importance
McEniery, C. M., Cockcroft, J. R., Roman, M. J., Franklin, S. S., & Wilkinson, I. B. (2014) · European Heart Journal · doi:10.1093/eurheartj/eht565 · Cited by 678
Self-citationCentral Blood Pressure Measurements and Antihypertensive Therapy: A Consensus Document
Agabiti-Rosei, E., Mancia, G., O’Rourke, M. F., Roman, M. J., Safar, M. E., Smulyan, H., Wang, J.-G., Wilkinson, I. B., Williams, B., & Vlachopoulos, C. (2007) · Hypertension · doi:10.1161/hypertensionaha.107.090068 · Cited by 620
Self-citationAvolio, A. P., Van Bortel, L. M., Boutouyrie, P., Cockcroft, J. R., McEniery, C. M., Protogerou, A. D., Roman, M. J., Safar, M. E., Segers, P., & Smulyan, H. (2009) · Hypertension · doi:10.1161/hypertensionaha.109.134379 · Cited by 521
Validation of a Brachial Cuff-Based Method for Estimating Central Systolic Blood Pressure
Weber, T., Wassertheurer, S., Rammer, M., Maurer, E., Hametner, B., Mayer, C. C., Kropf, J., & Eber, B. (2011) · Hypertension · doi:10.1161/hypertensionaha.111.176313 · Cited by 461
McEniery, C. M., Yasmin, McDonnell, B., Munnery, M., Wallace, S. M., Rowe, C. V., Cockcroft, J. R., & Wilkinson, I. B. (2008) · Hypertension · doi:10.1161/hypertensionaha.107.105445 · Cited by 429
Self-citation
Metadata
- Authors
- Sharman, J. E., Lim, R., Qasem, A. M., Coombes, J. S., Burgess, M. I., Franco, J., Garrahy, P., Wilkinson, I. B., & Marwick, T. H.
- Venue
- Hypertension
- Published
- 2006-06
- Volume
- 47
- Issue
- 6
- Pages
- 1203-1208
- ISSN
- 0194-911X (ISSN-L)
- 1524-4563
- OpenAlex
- W2127374591
- Cited by
- 308
- References
- 25
- FWCI
- 10.28
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validation of a Generalized Transfer Function to Noninvasively Derive Central Blood Pressure During Exercise. https://app.cochat.ai/papers/10.1161/01.hyp.0000223013.60612.72
- The paper
- Sharman, J. E., Lim, R., Qasem, A. M., Coombes, J. S., Burgess, M. I., Franco, J., Garrahy, P., Wilkinson, I. B., & Marwick, T. H. (2006). Validation of a Generalized Transfer Function to Noninvasively Derive Central Blood Pressure During Exercise. Hypertension. https://doi.org/10.1161/01.hyp.0000223013.60612.72
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.